Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

X-ray diffractometers

Is the RGD an intentional x-ray generating device, which produces radiation as part of the primary function (i.e., x-ray diffractometers, x-ray machine). [Pg.373]

X-ray powder diffraction studies are perfonned both with films and with counter diffractometers. The powder photograph was developed by P Debye and P Scherrer and, independently, by A W Hull. The Debye-Scherrer camera has a cylindrical specimen surrounded by a cylindrical film. In another commonly used powder... [Pg.1381]

An x-ray area detector can be used to collect the intensities of many reflections at a time. The crystal must be oriented in many different settings with respect to the incident beam but the detector needs to be positioned at only a few positions to collect all of the data. A charge coupled device (CCD) is used as the area detector on the Siemens SMART single crystal diffractometer system. The SMART detector consists of a flat 6-cm circular phosphorescent screen that converts x-ray photons to visible light photons. The screen is coupled to a tapered fiber optics bundle which is then coupled to a one inch by one inch square CCD chip. The CCD chip has 1024 x 1024 pixels each of which stores an electrical charge proportional to the number of... [Pg.376]

Fig. 12. Siemens SMART Single Crystal X-ray Diffractometer System. Fig. 12. Siemens SMART Single Crystal X-ray Diffractometer System.
Step 3. The computer collects about 45 frames of data. The crystal is rotated about the vertical axis for 0.3 degree for each frame. Usually the crystal is exposed to x-rays for about 5 seconds for each frame. The computer finds the centers of many reflections (typically 25 to several hundred) and determines indices for these reflections. It then determines the unit cell parameters and the orientation of the unit cells with respect to the diffractometer. [Pg.378]

Position Sensitive Detectors. By replacing the scintillation detector in a conventional powder diffractometer with a Position Sensitive Detector (PSD), it is possible to speed data collection. For each x-ray photon received a PSD records the angle at which it was detected. Typically, a conventional scintillation detector records x-ray photons in a range of a few hundredths of a degree at a time. A PSD can measure many degrees (in 20) of a powder pattern simultaneously. Thus, for small samples, data collection, which could require hours with a conventional detector, could take minutes or even seconds with a PSD. [Pg.381]

Area Detectors. A two-dimensional or area detector attached to a powder diffractometer can gready decrease data collection time. Many diffraction appHcations require so much time with a conventional detector that they are only feasible if an area detector is attached to the iastmment. The Siemens General Area Detector Diffraction System (GADDS) uses a multiwire area detector (Fig. 17). This detector measures an x- and ajy-position for each x-ray photon detected. The appHcations foUow. [Pg.381]

For x-ray investigations, the diffractometer method is generally used. The lattice constants indicate purity or composition of soHd solutions the rapid counting-tube goniometric method can be used at the manufacturing plant for quaUty control. The rotating-crystal and neutron diffraction methods are sometimes used for stmcture elucidation. [Pg.455]

Grazing Incidence X-Ray Diffraction Grazing Incidence X-Ray Diffraction Double Crystal Diffractometer... [Pg.769]

Once mounted in the diffractometer, the crystal is irradiated with X rays, usually so-called Cu/Cg radiation with a wavelength of 0.154 nm. When the X rays strike the enzyme crystal, they interact with electrons in the molecule and are scattered into a diffraction pattern, which, when delected and visualized, appears as a scries of intense spots against a null background. [Pg.865]

X-ray crystallography, 864-865 X-ray diffractometer. 865 oXylene, ozonolysis of, 542 Xylose, configuration of, 982... [Pg.1318]

FIGURE 2 A four-circle diffractometer is used to obtain highly detailed FIGURE 3 The x-ray diffraction pattern that led to the elucidation of the... [Pg.335]

Phase composition X-ray diffraction Philips diffractometer with Cu fine-focus tube... [Pg.325]

The crystal structures of four chlorinated derivatives of di-benzo-p-dioxin have been determined by x-ray diffraction from diffractometer data (MoKa radiation). The compounds, their formulae, cell dimensions, space groups, the number of molecules per unit cell, the crystallographic B.-factors, and the number of observed reflections are given. The dioxin crystal structures were performed to provide absolute standards for assignment of isomeric structures and have been of considerable practical use in combination with x-ray powder diffraction analysis. [Pg.14]

X-ray measurements were carried out with a small-angle diffractometer with a linear position-sensitive detector. Cu Ka radiation (X = 0.154 mn) was used (Mogilevski et al. 1984). The samples were rotated with respect to the incident beam, while the intensity was registered by linear position-sensitive detector. The angular resolution of the detector was 0.01°. The curves were acquired in the 20 range of 0.3-2.0°. X-ray reflection curves are presented in Figures 22 and 23 for wild-type and recombinant proteins, respectively. The... [Pg.169]

The data measurement in an x-ray analysis is typically performed using a computer controlled diffractometer. Except for the crystal mounting and some preliminary procedures, the measurement of intensities is fully automated. It is the next... [Pg.144]


See other pages where X-ray diffractometers is mentioned: [Pg.466]    [Pg.139]    [Pg.28]    [Pg.139]    [Pg.1404]    [Pg.466]    [Pg.139]    [Pg.28]    [Pg.139]    [Pg.1404]    [Pg.1382]    [Pg.4]    [Pg.375]    [Pg.377]    [Pg.379]    [Pg.379]    [Pg.380]    [Pg.382]    [Pg.203]    [Pg.203]    [Pg.651]    [Pg.30]    [Pg.170]    [Pg.405]    [Pg.720]    [Pg.865]    [Pg.300]    [Pg.124]    [Pg.144]    [Pg.240]    [Pg.249]    [Pg.249]    [Pg.355]    [Pg.335]    [Pg.15]    [Pg.249]    [Pg.202]   
See also in sourсe #XX -- [ Pg.99 ]




SEARCH



Diffractometer

The X-ray diffractometer beam path and detector

X-ray diffractometer

© 2024 chempedia.info