Differential scanning calorimetry energy

In an attempt to document the effect of the deep ocean environment on textile materials, modem materials were immersed at the site on the ocean floor for subsequent retrieval. While one set of samples was recovered after a three month period, additional samples have remained on the ocean floor since 1991 and are yet to be retrieved. The morphology of cellulosic fibers immersed for a three-month period has been investigated (S), The physical and chemical structure of dyed and undyed cotton fibers from the site compared with those of modem cotton and of cotton immersed on the ocean floor for three months were reported (70,77). Results of preliminary analyses on silk fibers using differential scanning calorimetry, energy dispersive x-ray spectoscopy, and scanning electron microscopy, have been reported (72). [Pg.130]

Differential scanning calorimetry (energy changes e.g. melting, transitions)... [Pg.310]

The cure of novolaks with hexa has been studied with differential scanning calorimetry (dsc) and torsional braid analysis (tba) (46) both a high ortho novolak and a conventional acid-cataly2ed system were included. The dsc showed an exothermic peak indicating a novolak—hexa reaction ca 20°C higher than the gelation peak observed in tba. Activation energies were also calculated. [Pg.299]

Thermoanalytical techniques such as differential scanning calorimetry (DSC) and thermogravi-metric analysis (TGA) have also been widely used to study rubber oxidation [24—27]. The oxidative stability of mbbers and the effectiveness of various antioxidants can be evaluated with DSC based on the heat change (oxidation exotherm) during oxidation, the activation energy of oxidation, the isothermal induction time, the onset temperamre of oxidation, and the oxidation peak temperature. [Pg.469]

A more detailed investigation of the thermal behavior of the exploding [ ]rotanes by differential scanning calorimetry (DSC) measurements performed in aluminum crucibles with a perforated lid under an argon atmosphere revealed that slow decomposition of exp-[5]rotane 165 has already started at 90 °C and an explosive quantitative decomposition sets on at 150 °C with a release of energy to the extent of AH(jecomp = 208 kcal/mol. Exp-[6]rotane 166 decomposes from 100°C upwards with a maximum rate at 154°C and an energy release of AH(jg on,p=478 kcal/mol. The difference between the onset (115°C) and the maximum-rate decomposition temperature (125-136°C) in the case of exp-[8]rotane 168 is less pronounced, and AHjecomp 358 kcal/mol. The methy-... [Pg.36]

Differential Scanning Calorimetry. A sample and an inert reference sample are heated separately so that they are thermally balanced, and the difference in energy input to the samples to keep them at the same temperature is recorded. Similarly to DTA analysis, DSC experiments can also be carried out isothermally. Data on heat generation rates within a short period of time are obtained. Experimental curves from DSC runs are similar in shape to DTA curves. The results are more accurate than those from DTA as far as the TMRbaiherm is concerned. [Pg.366]

Differential thermal analysis (DTA) is a technique in which the temperature difference between a substance and reference material is measured as a function of temperature or time while the substance and reference material are subjected to a controlled increase in temperature. Differential scanning calorimetry (DSC) is a technique in which the difference in energy inputs into the sample and reference material required to keep their temperatures equal is measured as a function of temperature while the substance and reference material are subjected to a controlled increase in temperature [70]. [Pg.51]

Differential scanning calorimetry (DSC) a technique in which the difference of energy inputs required to keep a substance and a reference material at the... [Pg.229]

Differential scanning calorimetry (DSC) was designed to obtain the enthalpy or the internal energy of those processes and also to measure temperature-dependent properties of substances, such as the heat capacity. This is done by monitoring the change of the difference between the heat flow rate or power to a sample (S) and to a reference material (R), A

[Pg.171]

The product from the distillation was analyzed by drop weight testing and differential scanning calorimetry (DSC). The drop weight test indicated that the product was not shock sensitive. By DSC, there was a 400 cal/g release of energy which initiated at 135°C. The pot residue showed a slow release of energy which was estimated to be ca. 100 cal/g and initiated at 150°C. [Pg.164]

The two most popular methods of calculation of energy of activation will be presented in this chapter. First, the Kissinger method [165] is based on differential scanning calorimetry (DSC) analysis of decomposition or formation processes and related to these reactions endo- or exothermic peak positions are connected with heating rate. The second method is based on Arrhenius equation and determination of formation or decomposition rate from kinetic curves obtained at various temperatures. The critical point in this method is a selection of correct model to estimate the rate of reaction. [Pg.60]

Differential scanning calorimetry is primarily used to determine changes in proteins as a function of temperature. The instrument used is a thermal analysis system, for example a Mettler DSC model 821e. The instrument coupled with a computer can quickly provide a thermal analysis of the protein solution and a control solution (no protein). The instrument contains two pans with separate heaters underneath each pan, one for the protein solution and one for the control solution that contains no protein. Each pan is heated at a predetermined equal rate. The pan with the protein will take more heat to keep the temperature of this pan increasing at the same rate of the control pan. The DSC instrument determines the amount of heat (energy) the sample pan heater has to put out to keep the rates equal. The computer graphs the temperature as a function of the difference in heat output from both pans. Through a series of equations, the heat capacity (Cp) can be determined (Freire 1995). [Pg.157]


See other pages where Differential scanning calorimetry energy is mentioned: [Pg.101]    [Pg.133]    [Pg.101]    [Pg.133]    [Pg.1916]    [Pg.2841]    [Pg.318]    [Pg.10]    [Pg.943]    [Pg.242]    [Pg.113]    [Pg.657]    [Pg.246]    [Pg.64]    [Pg.235]    [Pg.23]    [Pg.534]    [Pg.278]    [Pg.94]    [Pg.16]    [Pg.551]    [Pg.24]    [Pg.180]    [Pg.425]    [Pg.7]    [Pg.85]    [Pg.107]    [Pg.178]    [Pg.114]    [Pg.17]    [Pg.69]    [Pg.109]    [Pg.33]    [Pg.692]    [Pg.139]    [Pg.407]   
See also in sourсe #XX -- [ Pg.79 , Pg.85 ]