Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Devices cylinders

The simplest type of centrifugal device is the cyclone separator (Fig. 3.4), which consists of a vertical cylinder with a conical bottom. The centrifugal force is generated by the fluid motion. The mixture enters in a tangential inlet near the top, and the rotating motion so created develops centrifugal force which throws the particles radially toward the wall. [Pg.71]

The radiation and temperature dependent mechanical properties of viscoelastic materials (modulus and loss) are of great interest throughout the plastics, polymer, and rubber from initial design to routine production. There are a number of laboratory research instruments are available to determine these properties. All these hardness tests conducted on polymeric materials involve the penetration of the sample under consideration by loaded spheres or other geometric shapes [1]. Most of these tests are to some extent arbitrary because the penetration of an indenter into viscoelastic material increases with time. For example, standard durometer test (the "Shore A") is widely used to measure the static "hardness" or resistance to indentation. However, it does not measure basic material properties, and its results depend on the specimen geometry (it is difficult to make available the identity of the initial position of the devices on cylinder or spherical surfaces while measuring) and test conditions, and some arbitrary time must be selected to compare different materials. [Pg.239]

The measurement and evaluation methods of chapter 3.1. and 3.2. work with inductive sensors in an absolute circuit. The results on two different formed coils, a pot core coil and a cylinder core coil are selected. For presentation in this paper the third method, described in chapter 3.3., uses a Hall-effect device to detect the information and a coil system in a differential circuit to excite the electromagnetic field. [Pg.368]

Spray. For most purposes a simple spray device, based on the ordinary scent-spray, suffices. A finer and less intermittent spray can be obtained using the apparatus shown in Fig. 26. A narrow glass cylinder J has a ground-glass... [Pg.52]

The purification train. The oxygen is led from the cylinder through Ordinary flexible rubber condenser tubing to the constant level device A (Fig. 85). This consists of two concentric tubes (approximately 2 cm. and 0-5 cm. respectively, in diameter the inner tube being narrowed and curved at the bottom as shown) immersed in 50% aqueous potassium hydroxide contained in the outer vessel (diameter 3-5 cm.). Then by adjusting the liquid level in A the pressure of oxygen may be kept constant, and at a maximum of about... [Pg.467]

Wagner and DUlont have described a low-shear viscometer in which the inside diameter of the outer, stationary cylinder is 30 mm and the outside diameter of the inner, rotating cylinder is 28 mm the rotor is driven by an electromagnet. The device operates at 135°C and was found to be free of wobble and turbulence for shear rates between 3 and 8 sec V The conversion of Eq. (2.7) to Eq. (2.9) shows that F/A = (i7)(dv/dr) (instrument constant) for these instruments Evaluate the instrument constant for this viscometer. [Pg.128]

These modes of operation ate used in conjunction with the two most popular energy analyzers, the cylindrical mirror analyzer (CMA) and the concentric hemispherical analyzer (CHA). The most common form of the CMA used today is the double-pass version diagramed in Eigute 21. This device consists of two perfectly coaxial cylinders of radii r and r. The outer cylinder is held at a potential of (— ) and the inner cylinder is held at ground. The... [Pg.283]

Chlorine is stored and transported as a Hquefied gas in cylinders of 45.4-kg or 68-kg capacity that are under pressure and equipped with fusible-plug rehef devices. Quantities in the range of 15 to 90 t are transported in tank cars having special angle valves on the manhole cover on top of the vessel. Tank barges of the open-hopper type having several cylindrical uninsulated pressure vessels are used for amounts ranging from 600 to 1200 t. Road tankers are used for capacities of 15 to 20 t. [Pg.510]

Experimental Determination of the Burning Rate. Experimental determinations of the burning rate are made with the closed tomb for gun propellants and the strand burner for rocket propellants. The closed bomb is essentially a heavy-wahed cylinder capable of withstanding pressures to 689 MPa (100,000 psi). It is equipped with a piezoelectric pressure gauge and the associated apparatus requited to measure the total chamber pressure, which is directly related to the force of the propellant. It also measures the rate of pressure rise as a function of pressure which can then be related to the linear burning rate of the propellant via its geometry. Other devices, such as the Dynagun and the Hi—Low bomb, have also been developed for the measurement of gun propellant performance. [Pg.36]

Acetylene cylinders are fitted with safety devices to release the acetylene ia the event of fire. Cylinders manufactured ia the United States are equipped with safety devices which contain a fusible metal that melts at 100°C. In large cylinders the safety devices are ia the form of a replaceable, threaded steel plug with a core of fusible metal. Small cylinders (0.28 and 1.12 m 10 and 40 fT, respectively) may have the fusible metal ia passages ia the cylinder valve. [Pg.378]

Liquid carbon dioxide is used as a source of power in certain appHcations. The vapor pressure of Hquid carbon dioxide (7290 kPa or 72 atm at 294 K) maybe used for operating remote signaling devices, spray painting, and gas-operated firearms. Carbon dioxide in small cylinders is also used for inflating life rafts and jackets. [Pg.24]

Eunctional or hard chromium plating (169,175) is a successfljl way of protecting a variety of industrial devices from wear and friction. The most important examples are cylinder liners and piston rings for internal combustion engines. Eunctional chromium deposits must be appHed to hard substrates, such as steel, and are appHed in a wide variety of thicknesses ranging from 2.5 to 500 ]Am. [Pg.143]


See other pages where Devices cylinders is mentioned: [Pg.92]    [Pg.306]    [Pg.670]    [Pg.92]    [Pg.306]    [Pg.670]    [Pg.198]    [Pg.969]    [Pg.1958]    [Pg.535]    [Pg.566]    [Pg.897]    [Pg.246]    [Pg.81]    [Pg.83]    [Pg.36]    [Pg.130]    [Pg.77]    [Pg.102]    [Pg.379]    [Pg.379]    [Pg.428]    [Pg.150]    [Pg.5]    [Pg.327]    [Pg.563]    [Pg.1]    [Pg.1]    [Pg.296]    [Pg.349]    [Pg.184]    [Pg.188]    [Pg.190]    [Pg.190]    [Pg.191]    [Pg.435]    [Pg.464]    [Pg.466]    [Pg.364]    [Pg.450]    [Pg.459]   