Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detection methods effective

Knilurc Mailt (.Hu es Operating Mode Failure Effects Failure Detection Method Mitigation Sever- ity Remarks... [Pg.96]

Just like the physical and microchemical methods of detection, the indirect, biological-physiological detection procedures are very selective when apphed to thin-layer chromatography. Here it is not chemical functional groups or particular physical properties that are selectively detected but effects on highly sensitive biodetectors . The following detection techniques have been employed ... [Pg.109]

Sample preparation consists of homogenization, extraction, and cleanup steps. In the case of multiresidue pesticide analysis, different approaches can have substantially different sample preparation procedures but may employ the same determinative steps. For example, in the case of soil analysis, the imidazolinone herbicides require extraction of the soil in 0.5 M NaQH solution, whereas for the sulfonylurea herbicides, 0.5M NaOH solution would completely decompose the compounds. However, these two classes of compounds have the same determinative procedure. Some detection methods may permit fewer sample preparation steps, but in some cases the quality of the results or ruggedness of the method suffers when short cuts are attempted. For example, when MS is used, one pitfall is that one may automatically assume that all matrix effects are eliminated because of the specificity and selectivity of MS. [Pg.754]

The discussion above was concerned with the effects of solution conditions on enzyme activity, hence reaction velocity. Equally important for the purpose of assay design is the influence of specific solution conditions on the detection method being used. This latter topic is beyond the scope of the present text. Nevertheless, this is an important issue for screening scientists whose job is often to balance the needs of biochemical rigor and assay practicality in development of an HTS assay. An... [Pg.93]

Also, we have noted that patients with unilateral cataracts after trauma or retinal detachment repair typically have very similar RRS carotenoid levels in the normal and in the pseudophakic eye. Thus, we have concluded that there is a decline of macular carotenoids that reaches a low steady state just at the time when the incidence and prevalence of AMD begins to rise dramatically. While this age effect has been noticed sometimes also in other studies using clinical populations and different MP detection methods (Sharifzadeh et al. 2006, Nolan et al. 2007), several groups have reported constant, age-independent MP levels. Examples include reflectance-based population studies in which respective average MP optical densities of 0.23 (Delori et al. 2001), 0.33 (Berendschot et al. 2002), and 0.48 (Berendschot and Van Norren 2004) were determined. [Pg.95]

The amount of particles determine the quantity of decay products that stay in the air (equilibrium fraction, F) and the fraction of activity associated with the "unattached or ultrafine mode of the size distribution (fDot) These decay products are certainly harmful at high concentrations but we cannot yet detect the effects at normal levels because the vast majority of lung cancer death are due to smoking. Models predict that potentially 9000 lung cancer deaths per year in the United States are due to indoor radon. Methods are currently available and new methods are being developed and tested for lowering the levels of radon in indoor air. [Pg.583]

A number of different techniques have been applied to test the distance and orientation dependence of ET reactions (Closs and Miller, 1988 Closs et al, 1989 Liang et al., 1990 Reimers and Hush, 1990 Fox and Chanon, 1988 Wasielewski, 1989 Paddon Row and Jordan, 1988 Joachim et al, 1990 McConnell, 1961). Our method of analysing the mode of charge distribution in charged species is esr spectroscopy, which defines the timescale of the detectable dynamic species (Gerson, 1967 Kurreck et al, 1988 Wertz and Bolton, 1972). If an electron transfer is slow relative to the esr timescale (<10 7s) the spectrum corresponds to that of monomeric model compounds with a single electrophore. If the hopping process is rapid on the esr timescale, one will detect an effective delocalization. [Pg.21]

Yamamoto et al. [33] applied this technique to the determination of arsenic (III), arsenic (V), antimony (III), and antimony (V) in Hiroshima Bay Water. These workers used a HGA-A spectrometric method with hydrogen-nitrogen flame using sodium borohydride solution as a reductant. For the determination of arsenic (III) and antimony (III) most of the elements, other than silver (I), copper (II), tin (II), selenium (IV), and tellurium (IV), do not interfere in at least 30 000-fold excess with respect to arsenic (III) or antimony (III). This method was applied to the determination of these species in sea water and it was found that a sample size of only 100 ml is enough to determine them with a precision of 1.5-2.5%. Analytical results for surface sea water of Hiroshima Bay were 0.72 xg/l, 0.27 xg/l, and 0.22 xg/l, for arsenic (total), arsenic (III), and antimony (total), respectively, but antimony (III) was not detected. The effect of acidification on storage was also examined. [Pg.339]

The PSM Rule requires that a FMEA be performed by a team, all of whose members participate in the analysis. The most practical means of performing the FMEA is to prepare blank worksheets on viewgraphs or on a large display screen. For each equipment item, the PrHA team reaches a consensus on its failure modes and their causes, effects, detection methods, compensating provisions, severity (if desired), and any remarks or action items. [Pg.66]

FAILURE MODE CAUSE(S) OPERATIONAL MODE FAILURE EFFECTS FAILURE DETECTION METHOD COMPENSATING PROVISIONS SEVERITY CLASS REMARKS/ ACTIONS... [Pg.67]

Matrix effect is a phrase normally used to describe the effect of some portion of a sample matrix that causes erroneous assay results if care is not taken to avoid the problem or correct for it by some mechanism. The most common matrix effects are those that result in ion suppression and subsequent false negative results. Ion enhancement may lead to false positive results.126 127 Several reports about matrix effects include suggestions on what can cause them and how to avoid them.126-147 While various ways to detect matrix effects have been reported, Matuszewski et al.140 described a clear way to measure the matrix effect (ME) for an analyte, recovery (RE) from the extraction procedure, and overall process efficiency (PE) of a procedure. Their method is to prepare three sets of samples and assay them using the planned HPLC/MS/MS method. The first set is the neat solution standards diluted into the mobile phase before injection to obtain the A results. The second set is the analyte spiked into the blank plasma extract (after extraction) to obtain the B results. The third set is the analyte spiked into the blank plasma before the extraction step (C results) these samples are extracted and assayed along with the two other sets. The three data sets allow for the following calculations ... [Pg.220]


See other pages where Detection methods effective is mentioned: [Pg.811]    [Pg.1982]    [Pg.44]    [Pg.49]    [Pg.224]    [Pg.10]    [Pg.96]    [Pg.147]    [Pg.140]    [Pg.17]    [Pg.651]    [Pg.288]    [Pg.271]    [Pg.496]    [Pg.62]    [Pg.92]    [Pg.96]    [Pg.211]    [Pg.400]    [Pg.8]    [Pg.554]    [Pg.62]    [Pg.276]    [Pg.477]    [Pg.128]    [Pg.24]    [Pg.543]    [Pg.70]    [Pg.207]    [Pg.459]    [Pg.501]    [Pg.124]    [Pg.5]    [Pg.355]    [Pg.71]    [Pg.25]   
See also in sourсe #XX -- [ Pg.299 , Pg.300 , Pg.301 ]




SEARCH



Detection methods

© 2024 chempedia.info