Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data analysis degradation

Recall that, in order to generate an ILS calibration, we must have at least as many samples as there are wavelengths used in the calibration. Since we only have 15 spectra in our training sets but each spectrum contains 100 wavelengths, we were forced to find a way to reduce the dimensionality of our spectra to 15 or less. We have seen that principal component analysis (PCA) provides us with a way of optimally reducing the dimensionality of our data without degrading it, and with the added benefit of removing some noise. [Pg.99]

An additional consideration for sample preparation is to ensure that the final sample solution is miscible with the HPLC eluent and will not alter or degrade the column.62 The total time needed for sample preparation may be longer than that required to conduct chromatographic separation and therefore becomes is the rate-determining step for the analysis.63 A survey cited by several authors indicated that on average chromatography separation accounts for about 15% of the total analysis time, sample preparation, about 60%, and data analysis and reporting, 25%.64 66... [Pg.350]

The concentration profile during the dissolution testing of melphalan tablets in water and simulated gastric fluid was determined by HPLC. A method of data analysis was developed to take into account the spontaneous drug degradation [111]. [Pg.295]

The structure of Cypridina luciferin was established by analysis of spectroscopic data, chemical degradations, extensive MS analysis, and total synthesis [41—44]. Cypridina luciferin is biosynthesized from L-tryptophan, L-arginine, and L-isoleudne [45,46]. Distomadines A (24) and B (25) have been isolated from the asddian Pseudodistoma aureum and were not adive in antifungal, antiviral, anti-inflammatory, and anti-mycobacterial bioassays [47]. [Pg.309]

Kalahalide D (41) has been isolated from the marine mollusk Elysia rufescens and from the alga Bryopsis sp. and identified by analysis of spectroscopic data, chemical degradations, and chiral HPLC, GC, and TEC [65]. [Pg.312]

Porter (2) and Coscia (3) described the structures of six dendrobine alkaloids and one dendrobium salt. Although the structures of the dendrobines are less complex than those of most other picrotoxanes, their structure determination became feasible only after spectroscopic methods became generally available in the 1960s. Thus, in 1964, no less than three Japanese research groups completed independently the structure determination of dendrobine (82), the main alkaloid of D. nobile, using a combination of degradation reactions and spectroscopic data analysis (136-138). [Pg.129]

Inflation of Type I and Type II error rates, bias parameter estimates, and the degradation of the performance of confidence intervals are possible consequences of improperly addressing the issue of missingness in data analysis. Because a loss of... [Pg.259]

C-metolachlor used in the sorption and degradation studies. Finally, we appreciate Ms. Linda Lee s assistance in data analysis and in drafting the figures. [Pg.116]

Kinetic studies of materials degradation have long history, and there exists a long list of data analysis techniques employed for the purpose. Often, TGA is the method of choice for acquiring experimental data for subsequent kinetic calculations, and namely this technique... [Pg.9]

The repetition rate of Ti Sapphire lasers is fixed by the resonator length. Rates from 78 to 92 MHz are common. The high repetition rate helps to minimise classic pile-up effects in TCSPC measurements. However, it can cause problems if fluorescence lifetimes longer than 3 or 4 ns have to be measured, since the fluorescence does not decay completely within the pulse period. Data analysis can account for incomplete decay to a certain degree. However, if the lifetime becomes equal to or longer than the pulse period, the accuracy of the obtained lifetime degrades. The pulse repetition rate must therefore be reduced by a pulse picker. [Pg.266]


See other pages where Data analysis degradation is mentioned: [Pg.148]    [Pg.88]    [Pg.465]    [Pg.283]    [Pg.410]    [Pg.433]    [Pg.5]    [Pg.157]    [Pg.16]    [Pg.148]    [Pg.80]    [Pg.316]    [Pg.460]    [Pg.380]    [Pg.83]    [Pg.428]    [Pg.306]    [Pg.149]    [Pg.1]    [Pg.8]    [Pg.15]    [Pg.20]    [Pg.312]    [Pg.286]    [Pg.129]    [Pg.225]    [Pg.1097]    [Pg.66]    [Pg.753]    [Pg.370]    [Pg.99]    [Pg.54]    [Pg.2121]    [Pg.8275]   
See also in sourсe #XX -- [ Pg.68 , Pg.69 , Pg.70 , Pg.71 , Pg.72 , Pg.73 , Pg.74 , Pg.75 , Pg.76 , Pg.77 , Pg.78 ]




SEARCH



Data Analysis of DSC Heat Effects for the Most Representative (Bio)-degradable Polymers

Degradation analysis

© 2024 chempedia.info