The SCREEN model will then read the responses to its prompts from the EXAMPLE.DAT file rather than from the keyboard. The output from this run will be stored in a file called SCREEN, which can then be compared with the EXAMPLE.OUT file provided on the program. The file containing the redirected input data may be given any valid DOS pathname. To facilitate the creation of the input file for the SCREEN model, SCREEN has been programmed to write out all inputs provided to a file called SCREEN.DAT during execution. Therefore, at the completion of a run, if the user types the following, the last run will be exactly duplicated ... [Pg.300]

Alternatively, the SCREEN.DAT file may be edited as an ASCII file using a text or line editor, and selected input parameters changed before rerunning the model. Since the original SCREEN.DAT file will be overwritten each time the model is run, it is advisable to save the modified inputs under a different file name. [Pg.300]

Some cautions are needed regarding the use of redirected input with SCREEN. Because of the way some input errors are handled by SCREEN, the SCREEN.DAT file may contain some of the errors from the original input. [Pg.300]

More importantly, since the inputs requested by SCREEN depend on the options selected, it is not advisable to edit the SCREEN.DAT file and try to change the options selected. An experienced user may be able to do this, but it may be easier simply to rerun SCREEN with the new options. [Pg.300]

Data file FILLTUBE.xls.dat contains a set of 20 in-process controls (IPC) of n = 50 simulated weighings each. The first 10 vectors are for EU conditions (/i = 20.02 g), the others for Swiss regulations (/r = 20.35 g) a = 0.75 g. The default settings can be changed. Pressing [F9] initiates a new simulation. The results can be captured and incorporated into a. dat file, see program DATA, option (Import Data from Excel). For one specific simulation, the results were as follows. [Pg.241]

As. dat files (some programs, like DATA and SIMILAR, create or add to data files). The data structure is such that a. dat file can easily be imported into Excel by invoking (Open. ) and choosing the (Separated by Comma) option. [Pg.361]

This represents a slice through the two-dimensional potential energy surface defined by the two constrained torsion angles. The energy values and the associated torsion angles are recorded in the . dat file. This file should be copied to a new file and kept. [Pg.267]

Now change the Start value for the Co-N-C-C torsion angle to 40° and repeat the calculations. This generates the next slice of the potential energy surface and the results from the . dat file should be added to the file containing the previous slice. [Pg.267]

During the MultiCASE prediction, the output of the prediction is displayed in a text window on the screen (Figure 4c). This text will be automatically saved in an ASCII-file with a dat-file format. In parallel a second ASCII-file with a dat-file format will be saved when the prediction for a batch of molecules is performed, containing a short summary of all molecules (Figure 5). [Pg.812]

PURE.LST This file has a list of available polymers in this data base with their associated line number in the PURE.DAT file. [Pg.134]

First line number at which data for the polymer can be found in PURE.DAT file... [Pg.134]

The Registry is broken down into a series of separate areas called hives (see Figure 12.29). These keys are divided into two basic sections—user settings and computer settings. In Windows 9x, Registry information is stored in the user. dat and system. dat files, while in Windows 2000 a number of files are created corresponding to each of the different hives. The basic hives of the Registry include ... [Pg.510]

The Windows 9x emergency disk is a simple bootable disk that contains some basic utilities, like EDISK, ATTRIB, CHKDSK, DEBUG, EDH, EORMAT, RESTART, SCANDISK, and SYS. These files are used to correct basic disk problems as well as file boot problems. However, the Windows 9x emergency disk CANNOT be used to restore a corrupt Registry (apart from copying the USER.DAT and SYSTEM.DAT files from their backup locations). [Pg.705]

The awlOO.dat file contains isothermal VLE data for the acetone-water binary system at 100" C.)... [Pg.140]

Name of the diagram and comments COMM Ce02 Size Strain Round Robin ESRF Data Files = > DAT-file massonsh, PCR-file Ce02... [Pg.187]

EMBL-FORMAT= LibFormat [syntax EMBL SYNTAX contains DNASEQ DATA f ileType DAT-FILE SEQ FILE fields ... [Pg.452]

The MSEED solvation energy program uses the JRF.dat file, which defines the solvation parameters a, and evaluates the solvation energy at the current local minimum structure. [Pg.421]

C Store array of "I s" traced by particles in "MARK.DAT" file. [Pg.75]

PRESIX module prepares cross section for SIXTUS-2 module by reading (1) dependent input data, e.g. reactor power, core loading pattern, and number of fuel elements of each type from PRES.INP file (2) fuel element burnup history from ELEM.DAT file and (3) group constants for major materials used in the reactor from PRESIX.LIB If the fission products poisoning is considered. The corrections are calculated as equation (1)... [Pg.118]