Counter flow system

FIGURE 24.12 In order to prevent electrolysis products from entering the capillary at the connection of the capillary to high-pressure counter flow system, metal surfaces must he floating and isolated from the path of the electrophoretic current. (Reprinted from Henley, W. H., PhD Dissertation, University of North Carolina, Chapel Hill, 2005. Copyright 2005. With permission.)... [Pg.740]

Solvent extraction is used on both analytical and industrial scales and utilizes the high solubility of uranium in many organic solvents, in contrast to the low solubility of elements such as iron, thorium, radium, and rare earth elements. Uranium must be present in an ionic form in an aqueous solvent (see sample digestion) as solvent extraction will not extract colloids or complexes. Separation funnels or counter-flow systems can be used, with a higher efficiency and throughput possible using the counter-flow approach. [Pg.4159]

In fluid dynamics the behavior in this system is described by the full set of hydrodynamic equations. This behavior can be characterized by the Reynolds number. Re, which is the ratio of characteristic flow scales to viscosity scales. We recall that the Reynolds number is a measure of the dominating terms in the Navier-Stokes equation and, if the Reynolds number is small, linear terms will dominate if it is large, nonlinear terms will dominate. In this system, the nonlinear term, (u V)u, serves to convert linear momentum into angular momentum. This phenomena is evidenced by the appearance of two counter-rotating vortices or eddies immediately behind the obstacle. Experiments and numerical integration of the Navier-Stokes equations predict the formation of these vortices at the length scale of the obstacle. Further, they predict that the distance between the vortex center and the obstacle is proportional to the Reynolds number. All these have been observed in our 2-dimensional flow system obstructed by a thermal plate at microscopic scales. ... [Pg.250]

Any container or a flow system with three electrodes closely placed can be used for electrochemical studies. Some electrochemical cells are shown in Fig. 18b. 1. Most electrochemical cells contain three electrodes. These are the working electrode (W), counter electrode (C), and the reference electrode (R). Table 18b.2 shows the materials and properties of W, R, and C. [Pg.663]

Various mass spectrometer configurations have been used for the detection of explosives, such as ion traps, quadrupoles and time-of flight mass analyzers and combinations as MS/MS systems. The ionization method is usually APCI with corona discharge [24, 25]. An example is given in Figure 20, which shows the schematic diagram of an explosive mass spectrometer detector [25]. It is based on an ion trap mass analyzer, an APCI source with corona discharge and a counter-flow introduction (CFI) system. The direction of the sample gas flow introduced into the ion source is opposite to that of the ion flow produced by the ion source. [Pg.166]

Stripping can equally be done in single-stage, cross-flow, or counter-current systems. To illustrate how the overall concepts remain valid, the performance of a countercurrent cascade accepting as feed the scrubbed extract... [Pg.357]

The portable instrumentation and low power demands of stripping analysis satisfy many of the requirements for on-site and in situ measurements of trace metals. Stripping-based automated flow analyzers were developed for continuous on-line monitoring of trace metals since the mid-1970s [16,17]. These flow systems involve an electrochemical flow detector based on a wall-jet or thin-layer configuration along with a mercury-coated working electrode, and downstream reference and counter electrodes. [Pg.138]

Insert an immunosensor into the thin-layer cell flow system setup shown in Fig. 35.3. The cell is configured as a three-electrode system with a Ag/AgCl reference and stainless-steel counter electrode. The gasket thickness should be >500 pm. Details are given in Ref. [2]. [Pg.1189]

Figure 11. Variation of water vapor concentration in the cathode and the anode channel of the PEMFC with the MPL under the counter-flow mode at a setting of 0.5 A/cm2 measured using the TDLAS system. Figure 11. Variation of water vapor concentration in the cathode and the anode channel of the PEMFC with the MPL under the counter-flow mode at a setting of 0.5 A/cm2 measured using the TDLAS system.
The cross-, co- and counter-flow schemes are illustrated in Figure 4.17, together with the concentration gradient across a median section of the membrane. It follows from Figure 4.17 that system performance can be improved by operating a module in an appropriate flow mode (generally counter-flow). However, such improvements require that the concentration at the membrane permeate surface equals the bulk concentration of the permeate at that point. This condition cannot be met with processes such as ultrafiltration or reverse osmosis in which the permeate is a liquid. In these processes, the selective side of the membrane faces the... [Pg.183]

Tonkovich et al. [123] claimed a 90% size reduction due to the introduction of micro channel systems into their device, which made use of the hydrogen off-gas of the fuel cell anode burnt in monoliths at palladium catalyst to deliver the energy for the fuel evaporation. A metallic nickel foam 0.63 cm high was etched and impregnated with palladium to act as a reactor for the anode effluent It was attached to a micro structured device consisting of liquid feed supply channels and outlet channels for the vapor, the latter flowing counter-flow to the anode effluent... [Pg.370]

The availability of and improvement in membranes has rekindled some interest in dialysis in aroma research. Benkler and Reineccius (19, 20) initially published studies on the use of Nafion (Dupont) membranes for the separation of fat from flavor isolates. This would permit solvent extraction to be used in the isolation of aroma compounds from fat containing foods. Chang and Reineccius (21) later used a continuous tubular counter current flow system to accomplish this fat/aroma separation more efficiently. These membranes can be obtained commercially and have been improved in terms of membrane thickness and purity. While the aroma isolate obtained using this membrane may not perfectly reproduce the aroma being studied, this is an alternate technique for aroma isolation. [Pg.47]


See other pages where Counter flow system is mentioned: [Pg.214]    [Pg.486]    [Pg.212]    [Pg.225]    [Pg.232]    [Pg.281]    [Pg.214]    [Pg.486]    [Pg.212]    [Pg.225]    [Pg.232]    [Pg.281]    [Pg.124]    [Pg.15]    [Pg.315]    [Pg.10]    [Pg.308]    [Pg.381]    [Pg.207]    [Pg.820]    [Pg.872]    [Pg.713]    [Pg.321]    [Pg.209]    [Pg.120]    [Pg.56]    [Pg.258]    [Pg.1431]    [Pg.210]    [Pg.305]    [Pg.151]    [Pg.768]    [Pg.257]    [Pg.260]    [Pg.245]    [Pg.264]    [Pg.203]    [Pg.75]    [Pg.207]    [Pg.441]    [Pg.48]    [Pg.107]    [Pg.141]   
See also in sourсe #XX -- [ Pg.212 ]