Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control and Automation

Small but environrrientallyjnendly. The Chemical Engineer, March 1993 Huge increases in technology in the past distributed manufacturing in small-scale plants miniaturization of processes domestic methanol plant point-of-sale chlorine simpler and cheaper plants economy of plant manufacture process control and automation start-up and shut-down sensor demand [145],... [Pg.90]

To achieve such properties and to maintain them under practical service conditions it is essential that all phases are synthesized to high qualitative homogeneity and that the structural arrangement shown in Fig. 9.1 prevails homogeneously throughout the macroscopic body of the part. Synthesis is thus a critical step since not only chemical precision but also macroscopic homogeneity are critical properties requiring carefully controlled and automated unit operations. [Pg.259]

G. Olsson, M.K. Nielsen, Z.Yuan, A. Lynggaard-Jensen, and J.P. Steyer. Instrumentation, control and automation in wastewater systems. Technical Report 15, IWA, 2005. [Pg.199]

An advantage to precolumn derivatization is that there are no limitations with respect to reaction kinetics. Of course, rapid reaction is always desirable, but need not be the principal factor when choosing a derivatizing reagent. This means that a wide variety of chemistries are available for derivatization. However, it is important that very stable derivatives be formed. The limited stability of OPA derivatives is the reason why OPA is most commonly employed for postcolumn reaction. If it is to be used in the precolumn fashion, very well-controlled and automated (mechanized) sample/reagent handling immediately prior to injection must be employed. [Pg.80]

OPA (ortho-phthalaldehyde) Aex = 340 nm, Aem = 455 nm. Derivatives are not stable (minutes). OPA is best used as a postcolumn derivatizing reagent. Precolumn use necessitates well-controlled and automated (mechanized) handling of the sample/reagents to ensure uniformity of time elapsed from reaction to injection. It reacts with primary amines only. Proline can be detected only if first converted to primary amine by oxidative reagents like chloramine T or sodium hypochlorite. Conversely, the concomitant reaction with OPA followed by FMOC obviates this problem and is the basis of the AminoQuant system marketed by Hewlett-Packard... [Pg.83]

Figure 14.4 is the three-dimensional view of the process. The figure illustrates the relative water head at different stages. Because of flexible design, Ultrox UV/oxidation treatment systems have a number of advantages (1) very few moving parts (2) operation at low pressure (3) minimum maintenance (4) full-time or intermittent operation in either a continuous or batch treatment mode (5) use of efficient, low-temperature, and long-life UV lamps and (6) use of a microprocessor to control and automate the treatment process (Zeff and Barich, 1992). [Pg.550]

Manufacturing process control and automation systems can be divided into two main categories [3]. [Pg.588]

Automation and control — handles efforts in the area of process control and automation of process equipment. This group or person may also include IT expertise to the project. [Pg.19]

Two different software applications have been developed for this complex reaction system (1) Hardware control and automation this application enables one to set and control the pressure, liquids and gas flow and pressure, as well as the position of the mechanical parts of the system. It also allows one to program the variation of the different reaction conditions (64 variables in each reaction step) (2) Analysis and reaction monitoring this application enables the on-line monitoring of the GC analysis results and reporting, which facilitates the off-line data analysis and leads to nohuman data manipulations in the transfer to the genetic algorithm application. [Pg.142]

Performance of a stack of cells is limited by performance of the weakest cell in stack. It is therefore important to achieve high uniformity in performance of the individual cells in the stack, through stack design, mass production techniques, quality control, and automated stack assembly process. Optimum flow field design may be obtained by careful Computational Fluid Mechanic techniques and experimental validation including flow visualization techniques. [Pg.115]

ISA) and from the Scientific Apparatus Makers Association [now Measurement, Control, and Automation Association (MCAA)], both of which are updated periodically. An appreciation of accuracy and repeatability is especially important. Some applications depend on the accuracy of the instrument, but other applications depend on repeatability. Excellent accuracy implies excellent repeatability however, an instrument can have poor accuracy but excellent repeatability. In some applications, this is acceptable, as discussed below. [Pg.54]

In recent years, however, there has been a vertical integration of process systems-related engineering services. Computer software firms have purchased or merged with control and automation companies and process control consulting firms. It is now becoming feasible to use the same software, or have relatively transparent links that allow a smooth transition between simulation models for design, data reconciliation, and parameter estimation, online optimization, and control. [Pg.144]

Advanced consumables are needed for avoiding complicated and costly optimization techniques and replacing them by direct CMP. Reduction in consumable consumption is also desired, as slurry and polishing pad costs alone account for more than 50% of COO. Better control and automation techniques are required for the improved stability of the polishing process, most important of which are more accurate and reliable end-point detection systems. Further improvements in throughput and post-CMP cleaning procedures as well as defect density reduction are also desired. [Pg.364]

Johnson, M. (1997). Remote Turbidity Measurement with a Laser Reflectometer. Water Science Technol. Proc. 7th Int Workshop on Instrumentation, Control and Automation of Water and Wastewater Treatment and Transport Syst, July 6-9, Brighton, England, 37, 12, 255-261. Elsevier Science Ltd., Exeter. England. [Pg.226]


See other pages where Control and Automation is mentioned: [Pg.397]    [Pg.398]    [Pg.417]    [Pg.240]    [Pg.1143]    [Pg.88]    [Pg.135]    [Pg.547]    [Pg.547]    [Pg.120]    [Pg.161]    [Pg.22]    [Pg.300]    [Pg.202]    [Pg.561]    [Pg.169]    [Pg.169]    [Pg.574]    [Pg.332]    [Pg.1]    [Pg.144]    [Pg.81]    [Pg.27]    [Pg.238]    [Pg.356]    [Pg.200]   


SEARCH



And automation

Controllers automation

© 2024 chempedia.info