Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Continuous polarization measurements

Advantages. Polarization measurements permit continuous binding analysis with subsecond resolution if required. When applied in stop-flow mixing conditions the technique has the best time resolution of the methods presently available. [Pg.67]

It would be preferable to measure the pH continuously as the column is being eluted, instead of measuring the pH of the fractions. One or two laboratories have equipment for such work, for example, Rilbe and Pettersson (43). It must be pointed out, however, that such continuous pH measurements involve great experimental difficulties. The electrodes in the column affect the measurements (polarization effects, etc.). The electrolyte system in the column,and in the capillary tubes also intro-... [Pg.56]

Potentiodynamic polarization measurements are quite appropriate for determination of the pitting susceptibility of aluminum coatings, and/or the corrosion current density/ corrosion rate of coated steel products in general. ASTM G 102, Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements, describes the calculation of corrosion rates and other information from electrochemical measurements. Another example of the use of DC electrochemical methods to examine the corrosion performance of coated sheet materials is a study by D. A. Jones et al. [48]. The study used polarization resistance measurements to examine the mechanism of steel and coated sheet degradation under conditions of alternate immersion. Jones compared the polarization resistance of samples of low-carbon steel, unpainted galvanized, aluminum-coated, and Zn-Ni alloy coated steel during continuous immersion and alternate immersion. Alternate immersion cyclic exposure produced a thick oxide that led to significant underfilm attack. Jones found that phosphate pretreatment tends to increase the resistance of these materials to underfilm attack. This study is an excellent example of the way electrochemical measurements can be used as a complement to other techniques to elucidate mechanistic information. [Pg.628]

The molecular beam and laser teclmiques described in this section, especially in combination with theoretical treatments using accurate PESs and a quantum mechanical description of the collisional event, have revealed considerable detail about the dynamics of chemical reactions. Several aspects of reactive scattering are currently drawing special attention. The measurement of vector correlations, for example as described in section B2.3.3.5. continue to be of particular interest, especially the interplay between the product angular distribution and rotational polarization. [Pg.2085]


See other pages where Continuous polarization measurements is mentioned: [Pg.519]    [Pg.538]    [Pg.544]    [Pg.545]    [Pg.550]    [Pg.557]    [Pg.562]    [Pg.519]    [Pg.538]    [Pg.544]    [Pg.545]    [Pg.550]    [Pg.557]    [Pg.562]    [Pg.2788]    [Pg.763]    [Pg.112]    [Pg.61]    [Pg.61]    [Pg.587]    [Pg.936]    [Pg.147]    [Pg.213]    [Pg.183]    [Pg.330]    [Pg.2788]    [Pg.941]    [Pg.519]    [Pg.767]    [Pg.48]    [Pg.283]    [Pg.59]    [Pg.261]    [Pg.88]    [Pg.447]    [Pg.252]    [Pg.2754]    [Pg.683]    [Pg.530]    [Pg.247]    [Pg.472]    [Pg.734]   


SEARCH



Continuous measurements

Nonlinear optics continuous polarization measurements

Polarization continued)

Polarization measurement

Polarized measurements

© 2024 chempedia.info