Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conductivity range

Most of these compounds react readily with available oxygen, including H2O. These compounds have simple stoichiometries, iategral values of x,y, and exhibit conductivities ranging from iasulatiag to metal-like. [Pg.53]

Fig. 1. Logarithmic scale of the electrical conductivities of materials categorized by magnitude and carrier type, ie, ionic and electronic, conductors. The various categories and applications ate given. The wide conductivity range for the different valence/defect states of Ti oxide is highlighted. MHD is... Fig. 1. Logarithmic scale of the electrical conductivities of materials categorized by magnitude and carrier type, ie, ionic and electronic, conductors. The various categories and applications ate given. The wide conductivity range for the different valence/defect states of Ti oxide is highlighted. MHD is...
Table 2. Electrical Conductivity Ranges for Conductive Polymers... Table 2. Electrical Conductivity Ranges for Conductive Polymers...
The oxide solid elecU olytes have elecuical conductivities ranging from lO Q cm to 10 cm at 1000°C and these can be converted into diffusion coefficient data, D, for die oxygen ions by the use of the Nernst-Einstein relation... [Pg.160]

See 2-3.1. Typical laboratory conductivity meters have insufficient sensitivity to measure semiconductive and nonconductive liquids, in Appendix B, some tabulated conductivities appear as < suggesting that the instmment used was inappropriate. Some liquids listed as conductive might fall instead into the semiconductive category (e.g., cymene). Eor conductivities less than 100 pS/m especially, highly sensitive picoammeters are required to measure the small currents involved and great care is needed to avoid contamination of both the sample and the test cell. Several ASTM methods are available according to the conductivity range involved [143-146]. [Pg.63]

Graphite Low cost (5-15 cents per square foot) easy application excellent ESD (electrostatic discharge) performance. Less conductivity (ranging from 2 ohms to the thousands per square foot, depending upon the amount of graphite) modest shielding capability (up to 30-40 dB). [Pg.393]

Boiler performance is determined by the conductivity of the BW. The optimum conductivity range is dependent on the specific boiler design. [Pg.577]

FIGURE 4-21 Conductivity range of common conducting polymers, along with their chemical structure. (Reproduced with permission from reference 72.)... [Pg.127]

Recently Butler et al. [4] reported the deposition of nanocrystalline diamond films with the conventional deposition conditions for micrometer-size polycrystalline diamond films. The substrate pretreatment by the deposition of a thin H-terminated a-C film, followed by the seeding of nanodiamond powder, increased the nucleation densities to more than 10 /cm on a Si substrate. The resultant films were grown to thicknesses ranging from 100 nm to 5 fim, and the thermal conductivity ranged from 2.5 to 12 W/cm K. [Pg.2]

As might be expected, the properties of polythiophene show many similarities with those of polypyrrole. As with polypyrrole, polythiophene can be prepared via other routes than electrochemical oxidation both as the neutral material [390-392] or in the p-doped form [393]. This material is produced as an infusible black powder which is insoluble in common solvents (and stable in air up to 360°C), with conductivities ranging from approximately 10 11 Scm-1 in the neutral form [390] to 102 Scm-1 when doped [19, 393, 394]. Early work on thiophene polymers showed that the p-doped material is air-sensitive in that the conductivity decreases on exposure to the atmosphere [20, 395] although no evidence of oxygen-containing species was seen in XPS measurements [19],... [Pg.51]

The oxide solid electrolytes have electrical conductivities ranging from 10 1 1 cm-1 to 10 6 1 cm-1 at 1000°C and these can be converted... [Pg.160]

FIGURE 1.43 Conductivity range for LSGM, YSZ, and GDC. The range is plotted after Fergus with data estimated from Figures 2, 5, and 7 in reference [12]. [Pg.60]

The nonstationary theory deals with the thermal balance of the whole reaction vessel and assumes the temperature to be the same at all points. This assumption is, of course, incorrect in the conduction range where the temperature gradient is by no means localized at the wall. It is, however, equivalent to a replacement of the mean values of all temperature-dependent magnitudes by their values at a mean temperature, and involves relatively minor error. [Pg.392]

This process of creating electronic defects is called valence induction, and it increases the conductivity range of NiO tremendously. Indeed, at high Li concentrations, the conductivity approaches that of a metal (although it still exhibits semiconductor behaviour in that its conductivity increases with temperature). [Pg.275]

In the presence of liquid HF, graphite is found to be reversibly intercalated by fluorine. First-stage materials have the composition Ci2(HF)F (l < n < 5), and the ultimate salt is the second-stage bifluoride C,2HF2. Extensive studies on these intercalates by Mallouk et al, (1985) have shown conductivities ranging from the metallic to the insulator regime. [Pg.493]

Table 4 summarizes the conductivity ranges reported for various PEO-salt systems and suggests that the conductivities depend on (a) polymer molecular weight (b) polymer-salt ratio (c) temperature. As expected, the polymer-salt ratio is one of the most significant factors. [Pg.120]

Dia-Log Co. manufactures p-jump units with optical conductivity detection capabilities. A photograph of the p-jump unit with conductivity detection is shown in Fig. 4.6. Relaxation times of 50 >Lts—100 s can be measured. The conductivity range is 200 S m-1 to 0.05 S m-1, the temperature range is 273-343 K, and a sample volume of 0.5 ml or more can be used with a readout digitizer that has a memory of up to 256 values. It provides automatic data processing and data reduction with a microprocessor. The data can also be evaluated with PET, HP 67, or Wang 600 and 720 hand-held calculators. [Pg.79]

Distilled laboratory water has a conductivity range of 0.5-3 pmho/cm. The conductivity of drinking water in the USA ranges from 50 to 1500 pmho/cm (APHA, 1998). Conductivity of groundwater varies depending on the concentration of dissolved solids. That is why total dissolved solids (TDS) content can be estimated from a conductivity measurement. We can approximate the TDS in milligram per liter (mg/1) by dividing the conductivity value in pS/cm by a factor of two. [Pg.171]

M 4] [P 3] EKI mixing was demonstrated for mixers made of polymer materials such as PDMS or PMMA and of glass [25], Processing with various electrolytes could be successfully applied, including deionized water and borate and HEPES buffers, with electrical conductivities ranging from 5 to 250 pS cm4. [Pg.23]


See other pages where Conductivity range is mentioned: [Pg.354]    [Pg.532]    [Pg.185]    [Pg.338]    [Pg.612]    [Pg.512]    [Pg.124]    [Pg.274]    [Pg.275]    [Pg.282]    [Pg.291]    [Pg.41]    [Pg.62]    [Pg.458]    [Pg.139]    [Pg.359]    [Pg.69]    [Pg.70]    [Pg.16]    [Pg.25]    [Pg.147]    [Pg.30]    [Pg.199]    [Pg.337]    [Pg.354]    [Pg.1347]    [Pg.259]    [Pg.344]    [Pg.183]    [Pg.52]   


SEARCH



© 2024 chempedia.info