Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatography apparatus for

Rudolph, J., Bachmann, K. Gas-chromatography apparatus for the investigation and separation of radioactively labeled incnganic-compounds at high-temperatures. Mikrochim. Acta 1, 477-493 (1979)... [Pg.306]

H. Yamamoto, T. Manabe and T. Okuyama, Apparatus for coupled high-performance liquid chromatography and capillary electrophoresis in the analysis of complex protein mixtures , 7. Chromatogr. 515 659-666 (1990). [Pg.214]

Gamma, of a photographic emulsion 769 Gas chromatography 235 apparatus for, 235 column packing for, 238 derivatisation in, 236 detectors for, 240 elemental analysis by, 247 of metal chelates 237, 248 pyrolysis, 237... [Pg.864]

The first part of the book consists of a detailed treatment of the fundamentals of thin-layer chromatography, and of measurement techniques and apparatus for the qualitative and quantitative evaluation of thin-layer chromatograms. In situ prechromatographic derivatization techniques used to improve the selectivity of the separation, to increase the sensitivity of detection, and to enhance the precision of the subsequent quantitative analysis are summarized in numerous tables. [Pg.4]

Figure 4-1. Components of a simple liquid chromatography apparatus. R Reservoir of mobile phase liquid, delivered either by gravity or using a pump. C Glass or plastic column containing stationary phase. F Fraction collector for collecting portions, called fractions, of the eluant liquid in separate test tubes. Figure 4-1. Components of a simple liquid chromatography apparatus. R Reservoir of mobile phase liquid, delivered either by gravity or using a pump. C Glass or plastic column containing stationary phase. F Fraction collector for collecting portions, called fractions, of the eluant liquid in separate test tubes.
Figure 8.45 Apparatus for pyrolysis gas chromatography. A, filament or ribbon-type pyrolyzer and B, Curie-point pyrolyzer. (Reproduced with perm.i ion from ref. 848. Copyright American Chemical society). Figure 8.45 Apparatus for pyrolysis gas chromatography. A, filament or ribbon-type pyrolyzer and B, Curie-point pyrolyzer. (Reproduced with perm.i ion from ref. 848. Copyright American Chemical society).
Size-exclusion chromatography (SEC) has been used to characterize the unimer-micelle distribution. However, SEC is not an absolute method and thus requires calibration. Since it is practically impossible to calibrate a SEC apparatus for the unimers and micelles formed by a block copolymer, only indicative MW values can be obtained. Moreover, several authors have noted a strong perturbation of the unimer-micelle equilibrium during SEC experiments even when interaction of the material with the SEC column was minimized [4,61,62],... [Pg.92]

Commonly used methods for the determination of petroleum hydrocarbon contamination in soil are modifications of Environmental Protection Agency method 418.1, which use sonication or a Soxhlet apparatus for analyte extraction and either infrared spectrometry [5] or gas chromatography with flame ionization detection [6-7] for extract analysis. Regardless of the analytical method following the extraction, both modifications use Freon-113, which has been implicated as a cause of ozone depletion. Therefore, alternative methods are being sought for the determination of hydrocarbon contamination in environmental samples that reduce the need for this halogenated solvent. [Pg.119]

Ellin, R. I., Earrand, R. L., Oberst, E. W., etal. (1974). An apparatus for the detection and quantitation of volatile human effiuents. Journal of Chromatography 100,137-152. [Pg.457]

Fig. 16.3 Apparatus for gas chromatography-olfactometry of static headspace samples (from [60])... Fig. 16.3 Apparatus for gas chromatography-olfactometry of static headspace samples (from [60])...
A gel permeation chromatography apparatus was adapted for use in pumping and fractionating samples in order to study the adsorption characteristics of the XAD-4 quaternary resin in the OH" form. [Pg.534]

Analysis of Volatile Matter Evolved. An attempt was made to establish the particular volatile component or components responsible for decrepitation by using a Beckman gas chromatography apparatus as described below. It was considered that comparing the analyses obtained at different temperatures with the corresponding rate of volatile matter evolution from the experimental work described previously would perhaps indicate the presence of a thermal decomposition reaction of controlling importance. [Pg.598]

A. Solid -liquid Adsorption Chromatography or Column Chromatography. An apparatus for conducting this technique consists of the following parts(See Fig) ... [Pg.73]

DH Spackman, WH Stein, S Moore. Automatic recording apparatus for use in the chromatography of amino acids. Anal Chem 30 1190-1206, 1958. [Pg.94]


See other pages where Chromatography apparatus for is mentioned: [Pg.124]    [Pg.71]    [Pg.63]    [Pg.124]    [Pg.71]    [Pg.63]    [Pg.21]    [Pg.195]    [Pg.780]    [Pg.68]    [Pg.109]    [Pg.865]    [Pg.554]    [Pg.27]    [Pg.202]    [Pg.209]    [Pg.476]    [Pg.479]    [Pg.39]    [Pg.85]    [Pg.80]    [Pg.279]    [Pg.96]    [Pg.466]    [Pg.106]    [Pg.279]    [Pg.19]    [Pg.20]    [Pg.596]    [Pg.174]   
See also in sourсe #XX -- [ Pg.158 ]




SEARCH



Apparatus for

Chromatography apparatus

Chromatography, apparatus for continuous

© 2024 chempedia.info