FIGURE 3.1 Scheme of classic trial-and-error approach toward the chemical model determination using general regression minimization methods. [Pg.62]

A new scheme for the chemical model determination in equilibria studies might include except statistical tests (1) the application of factor analysis to estimate directly the number of species in solution and (2) the method of direct computation of species stoichiometry via simultaneous calculation of stability constants and stoichiometric indices—the ESI approach. The ESI method might also be used as a new diagnostic tool when searching the best chemical model. The proposed novel scheme of CMD based on PCA and ESI is schematically given in Figure 3.6. [Pg.83]

The commonly used method for the determination of association constants is by conductivity measurements on symmetrical electrolytes at low salt concentrations. The evaluation may advantageously be based on the low-concentration chemical model (lcCM), which is a Hamiltonian model at the McMillan-Mayer level including short-range nonelectrostatic interactions of cations and anions [89]. It is a feature of the lcCM that the association constants do not depend on the physical... [Pg.465]

The determination of a realistic reaction network from experimental kinetics data may be difficult, but it provides a useful model for proper optimization, control, and improvement of a chemical process. One method for obtaining characteristics of the... [Pg.106]

Simulation and predictive modeling of contaminant transport in the environment are only as good as the data input used in these models. Field methods differ from laboratory methods in that an increase in the scale of measurement relative to most laboratory methods is involved. Determination of transport parameters (i. e., transmission coefficients) must also use actual contaminant chemical species and field solid phase samples if realistic values are to be specified for the transport models. The choice of type of test, e.g., leaching cells and diffusion tests, depends on personal preference and availability of material. No test is significantly better than another. Most of the tests for diffusion evaluation are flawed to a certain extent. [Pg.234]

The parameters of Hamiltonians (1) and (2) are determined in our approach by pure theoretical way using different quantum chemical models and calculations unlike the traditional fitting the experimental thermodynamic and dielectric data. Our method of the many-pseudospin clusters [ 1,4] seems to be the most reliable way of determination. The latter are obtained in this case within the static approximation from the system of equations for a typical crystal fragment (cluster) for all possible proton distributions on H-bonds. The left-hand side of any equation expresses the cluster total energy in terms of Jy, while the right-hand side is determined by means of the quantum chemical calculation of this energy. [Pg.581]

Q)S AR methods are based on the assumption that the variance in the endpoint for a group of similar chemicals is determined by the variance in their molecular structures. Consequently, when the values of the endpoint are available only for a part of the group, it is possible to interpolate the lacking data from an appropriate mathematical model. Such a model should correlate the endpoint (dependent... [Pg.202]

X-ray diffraction does not separate atoms that are Periodic Table neighbours well, as the scattering factors of these species are so similar. Thus, problems such as the distribution of Fe2+ and Fe3+ over the available sites in a crystal structure may be unresolved by conventional structure determination methods. The bond valence model is an empirical concept that correlates the strength of a chemical bond between two atoms and the length of the bond. Because crystal structure determinations yield accurate interatomic distances, precise values of the bond strength, called the experimental bond valence, can be derived. [Pg.182]

Now we turn to the single most important parameter estimation problem in chemical reactor modeling determining reaction-rate constants given dynamic concentration measurements. We devote the rest of the chapter to developing methods for this problem. [Pg.284]

The chemical mixtures composed of 32 probe compounds were prepared in aqueous solutions. The partition coefficients of chemicals were determined by PDMS membrane-coated fibers. The partition coefficient can be obtained by equilibrium or regression methods. In the equilibrium method, the absorption amount n° is determined at a predetermined equilibrium time. The partition coefficient of a chemical can be calculated from the equilibrium absorption amount n° and the initial concentration Q (Xia et al., 2003). The equilibrium absorption amount n° can also be obtained by regression of the absorption data sampled before the equilibrium with a kinetic model. The absorption experiment time can be reduced considerably with the regression method (Xia et al., 2004). [Pg.80]


See other pages where Chemical model determination methods is mentioned: [Pg.408]    [Pg.645]    [Pg.437]    [Pg.130]    [Pg.155]    [Pg.3]    [Pg.87]    [Pg.509]    [Pg.1]    [Pg.256]    [Pg.489]    [Pg.150]    [Pg.275]    [Pg.48]    [Pg.216]    [Pg.332]    [Pg.50]    [Pg.51]    [Pg.51]    [Pg.232]    [Pg.2590]    [Pg.571]    [Pg.267]    [Pg.27]    [Pg.327]    [Pg.615]    [Pg.189]    [Pg.5]    [Pg.2]    [Pg.308]    [Pg.411]    [Pg.164]    [Pg.455]    [Pg.61]    [Pg.379]    [Pg.461]    [Pg.6]    [Pg.129]    [Pg.42]   