Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Channel monitoring

A second source of cross talk occurs for mixtures of precursor-product ions with similar masses. Figure 6b shows the interference occurring when product and precursor ions within 1 Da of each other are monitored simultaneously for an analyte with the structure shown in Fig. 6a. The actual analyte signal should be observed only for a channel monitoring the 416.9-to-244.9 transition. Similar, although less intense, peaks are observed, however, for a precursor mass of 415.9 and/or a product ion mass of 243.9. This cross talk is caused by insufficient mass selectivity in the first quadrupole that allows the M — 1 to be transmitted. [Pg.150]

S. Metz, B. A. D. Bertrand, and P. Renaud, Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. Biosensors and Bioelectronics, 19(10), 1309-1318, 2004. [Pg.383]

The use of coincidence and fixed limit trips cem minimize these practices. Section VIII contains a special report in its entirety, HW-7565T "Logic For Reactor Safety Circuit Systems", which objectively discusses the relationship of continuity of operation and nuclear safety as system logic (multiple channel monitoring of a single parameter point) is applied to Reactor Safety Circtiits and Safety... [Pg.15]

It is necessary to monitor certain parameters of the process equipment to control damage or deterioration of parts or materials vhlch affect the life of a reactor. Ihstruments used for this application are classed as "Operating Instruments" and need lie only single channel monitors. [Pg.24]

At present the Barton-Mstrlsite transducer unit and the electronic monitoring system (Avien) used in the BSD Beactor could be ap[ ied to the older reactors successfully. However the cost is in excess of 1000 per channel monitored. [Pg.44]

Twenty-four in-core fission chambers located in the fuel channels monitor neutron flux and are used to... [Pg.14]

Samples with wild type sequence only had a signal in the channels monitoring masses representative of both wild type sense (ATA-s) and wild type antisense (ATA-as) alleles. A sample for an individual who is heterozygous at this locus has signals in the sense and antisense channels for both the wild type (ATA) and mutant (AAA) alleles. In a blind analysis of 16 individuals by SOMA and sequencing there was 1(X)% concordance. [Pg.82]

Methods for individual channel monitoring do not yet seem to be cost-effective. However, new methods for large-scale self-assembly of electronic components seem to offer an approach that may make individual channel monitoring possible at an affordable cost. The assumption is that early detection of device performance changes should allow more precise control of product quality. [Pg.1108]

The dual-path storage oscilloscope is a device fitted with two independent analog inputs, a two-channel AD converter, a two-channel monitor, two input memories and one output memory, and a DA converter with an integrated analog filter. [Pg.70]

The diagnosis partition performs local and cross-channel monitoring diagnosis... [Pg.9]

Additionally, a standard coincidence circuit with a 19 ns coincidence window monitors the rate of coincidences around null delay, while a delayed-coincidence channel monitors the accidental rate. It is then possible to check that the true coincidence rate obtained by substraction is equal to the signal in the peak of the time-delay spectrum. [Pg.119]


See other pages where Channel monitoring is mentioned: [Pg.76]    [Pg.234]    [Pg.284]    [Pg.225]    [Pg.145]    [Pg.323]    [Pg.1434]    [Pg.364]    [Pg.60]    [Pg.65]    [Pg.46]    [Pg.498]    [Pg.17]    [Pg.405]    [Pg.260]    [Pg.260]    [Pg.280]    [Pg.348]    [Pg.183]    [Pg.100]    [Pg.385]    [Pg.130]    [Pg.153]    [Pg.149]    [Pg.502]    [Pg.169]   
See also in sourсe #XX -- [ Pg.110 ]




SEARCH



Calcium channel blockers monitoring

Intrazeolite diffusion, dye molecules in zeolite channels, energy transfer monitoring

Monitor channel

Monitor channel

Multiple-reaction monitoring channels

Schematic diagram of the consecutive, simultaneous, exhaustive procedure for statistical decision-making in a multi-channel microwave-monitoring system

© 2024 chempedia.info