The thermocycle system can be operated only when condensing water is available at a temperature lower than the required chilled-water-supply temperature. Modifications for a centrifugal refrigeration unit include the installation of a small liqmd-refrigerant pump, cooler spray header nozzles, and a vapor bypass line between the cooler and the condenser. Without the compressor operating, a thermocycle capacity up to 35 percent of the refrigeration-unit rating can be produced. [Pg.1167]

Let s say we have a centrifugal refrigeration compressor, driven by a motor. The motor is tripping off because of high amperage. Should we open or close the suction throttle valve shown in Fig. 22.2 Answer— close it. Of course, both the evaporator vapor outlet temperature and the process fluid outlet temperature will increase. But that is the price we pay for having too small a motor driver on the compressor. Does this mean that when our home air conditioner gets low on freon, our electric bill drops Correct. But the price we pay is a hot home. [Pg.295]

Centrifugal Refrigeration Units - + 40 to -40°F 75 tons 133k to 161k... [Pg.272]

Filter (0.45mm) or centrifuge (refrigerated, lOOOOg) sample. [Pg.69]

Other alternatives to counteract haze include the adsorbants silica hydrogels, bentonite and polyvinylpolypyrrolidone (PVPP), the precipitant, tannic acid, and the proteolytic enzyme, papain. These additives, unfortunately, may leave residues in the beer and each may then be associated with problems in the finished product, for example, papain and bentonite may lessen foam stability and some hydrogels have been implicated in the formation of solid materials in the beer (Nelson and Young, 1986 Bamforth, 1988). Suggested physical alternatives are centrifugation, refrigeration and filtration (Hashimoto, 1981 Mathews, 1990). [Pg.223]

Most large centrifugal refrigeration compressors are driven by steam turbines. A gradual loss in refrigeration duty can be due to a reduction in turbine horsepower. An approximate method for calculating small changes in compressor horsepower is ... [Pg.116]

To be successful, Liz and I have to understand in a fundamental way how the equipment actually works. It s true that I do a lot of work with centrifugal refrigeration compressors. However, contrary to what my mother told Mrs. Goldberg, I am not a Frigidaire repairman. [Pg.777]

The Mam2en process uses ethylene gas as a direct refrigerant in a two-stage process (77,78). The first stage slurry is centrifuged, partially remelted, and fed to the second centrifuge. [Pg.419]

Crea.m Yeast. At a 5% soHds concentration in the fermentor, the yeast occupies about 12% of the fermentor volume. It is harvested by centrifugation in nozzle centrifuges and washed several times with water. The final centrifugate is cooled and stored in refrigerated tanks. This yeast cream (so called because of its off-white color) may be sold directly in this form, since in large baking faciHties, it may be piped directly to any desired location. [Pg.389]

Low cholesterol egg products are formed by extraction of cholesterol from the egg. Attempts have been made to extract cholesterol by using hexane or by supercritical CO2 extraction methods (24,25). A whole egg product in which 80% of the cholesterol is removed by a process using beta-cyclodextrin, a starch derivative, added to egg yolks has been introduced. The cyclodextrin binds up to 80% of the cholesterol, the mixture is centrifuged, and the Hquid separated. The cholesterol-reduced yolk is then blended with egg white, pasteurized, and packed in asceptic containers to give a Hquid whole egg product having a shelf Hfe of 60 days under refrigeration (see Eood packaging). [Pg.460]

A 7.7 mg portion of band 5 was taken up in a minimum of acetone and refrigerated until crystals separated. This cold acetone mixture was centrifuged and the supernatant liquid removed by pipette. To the remaining crystals, a few drops of ice-cold ether-acetone, three to one mixture, were added, shaken, recentrifuged and the supernatant wash liquid removed by pipette. The ether-acetone wash was repeated. The resulting crystals were dried under vacuum yielding 3.3 mg of pure compound F, 17-hvdroxycorticosterone. [Pg.777]


See other pages where Centrifuge refrigerated is mentioned: [Pg.1167]    [Pg.384]    [Pg.990]    [Pg.21]    [Pg.203]    [Pg.1171]    [Pg.188]    [Pg.1167]    [Pg.384]    [Pg.990]    [Pg.21]    [Pg.203]    [Pg.1171]    [Pg.188]    [Pg.252]    [Pg.374]    [Pg.417]    [Pg.418]    [Pg.361]    [Pg.458]    [Pg.529]    [Pg.67]    [Pg.194]    [Pg.327]    [Pg.329]    [Pg.334]    [Pg.335]    [Pg.335]    [Pg.1105]    [Pg.1110]    [Pg.1110]    [Pg.1113]    [Pg.515]    [Pg.451]    [Pg.99]    [Pg.137]    [Pg.198]    [Pg.457]    [Pg.1118]    [Pg.1050]    [Pg.25]    [Pg.308]   