Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cells differential temperature

A 52-year-old man was admitted to the hospital for abdominal surgery. He developed complications postoperatively and was intubated 6 days ago. The nurses note an increase in the amount and purulence of his sputum. Attempts yesterday and today to wean the patient off the ventilator have failed. He is sedated but does respond to commands. His temperature is 38.4°C, his blood pressure is 120/84 mm Hg, and his white blood cell (WBC) count is 14.2/mm3 with a cell differential of 76% neutrophils, 4% bands, 16% lymphocytes, and 4% monocytes. [Pg.1051]

We use differential scanning calorimetry - which we invariably shorten to DSC - to analyze the thermal properties of polymer samples as a function of temperature. We encapsulate a small sample of polymer, typically weighing a few milligrams, in an aluminum pan that we place on top of a small heater within an insulated cell. We place an empty sample pan atop the heater of an identical reference cell. The temperature of the two cells is ramped at a precise rate and the difference in heat required to maintain the two cells at the same temperature is recorded. A computer provides the results as a thermogram, in which heat flow is plotted as a function of temperature, a schematic example of which is shown in Fig. 7.13. [Pg.150]

At the end of the sixties, Godovsky 64 71> developed a fully automatic deformation microcalorimeter based on the Tiang-Calvet principle for simultaneous recording of thermomechanical behaviour of rubbers and solids (films, fibres) at uniaxial deformation. The device consists of two parts a microcalorimeter and a mechanical loading system with dynamometric assembly. The differential microcalorimeter includes the working and the reference cells. The temperature difference between the... [Pg.56]

Equation (12.31) gives the relation between the emf of a cell and the change of the Gibbs energy for the cell reaction. Temperature differentiation gives... [Pg.340]

This work is a continuation of our earlier study [1] of the hydrogen interaction with intermetallic compound (IMC) AB2-type Tio.9Zro.1Mn . 3V0.5. The measurements were carried out in twin-cell differential heat-conducting Tian-Calvet type calorimeter connected with the apparatus for gas dose feeding, that permitted us to measure the dependencies of differential molar enthalpy of desorption (AHdes.) and equilibrium hydrogen pressure (P) on hydrogen concentration x (x=[H]/[AB2]) at different temperatures simultaneously. The measurements were carried out at 150°C, 170°C and 190°C and hydrogen pressure up to 60 atm. [Pg.443]

There are several basic types of fuel cells, differentiated by their electrolytes and by the temperature ranges in which they operate12 ... [Pg.156]

DTA Instrumentation. The differential thermograph used in this study has been described in detail (1, 2, 3). The microcalorimeter cell which used 0.005 gram of sample was used. The thermograms were recorded on an x-y recorder with the differential temperature, A T, on the y-axis and the sample temperature, T, on the x-axis. The sample temperature was measured with the same thermocouple as the AT. This produces thermograms with peak locations independent of heating rate. The heating rate was 4°C./minute. The calorimeter was calibrated with zone-purified dotriacontane, AHr + AHf = 51.7 cal./gram. [Pg.9]

Differential pressure in fuel cell stack Range 0-1 psi or (0-10 or 1-3 psi, depending on the design ofthe fuel cell system) Temperature range 30-100 C Survivability -40 0 Response time <1 sec Accuracy 1% offull scale Size <1 in, usable in any orientation Other Withstand and measure liquid and gas phases... [Pg.634]

Several modifications of differential scanning calorimeters, DSC, have been developed during the last few years for the measurement of enthalpies of phase changes [194-197] and Knudsen cells have been used as calorimetric cells. Modulated temperature thermogravimetry has also been proposed for the measurement of enthalpies of sublimation [198]. [Pg.560]

Differential Temperature Cells. Components of these cells are electrodes of the same metal, each of which is at a different temperature, immersed... [Pg.14]

Nandkumar, M. A., Yamato, M., Kushida, A., Konno, C., Hirose, M., Kikuchi, A., et al. (2002). Two-dimensional ceU sheet manipulation of heterotypically co-cultured lung cells utilizing temperature-responsive culture dishes results in long-term maintenance of differentiated epithelial ceU functions. Biomaterials, 23, 1121-1130. [Pg.39]

In order to determine molecular weight by light scattering, the refractive index Hq of the solvent and the refractive index increment dn/dc) for the solution at a constant temperature must be known. The former is readily measured with a simple laboratory refractometer such as the Abbe type. Determination of dnjdc) of the solution with high accuracy can be achieved by using two types of refractometers divided-cell differential refractometers and interferometers. [Pg.132]

The first differential scanning calorimeter was introduced by Watson et al. (1964) (Fig. 10.2(a)). A number of new developments in the instrumentation have since been made. The temperature scan is controlled, and data are collected and analysed by computers in today s instruments. Simultaneous measurements of differential temperature (AT) and sample weight, i.e. combined DTA and TG as well as combined DTA and TO A, are now commercially available. High-pressure DTA instruments have been in use since the early 1970s. In 1966, Cohen and co-workers constructed a DTA cell which could be... [Pg.218]

Differential Refractometry This relies on the image displacement AX of beams from the light source, which traverse pure solvent and polymer solution in a divided cell. Adequate temperature control is necessary and it is essential to utilize a stoppered cell to prevent solvent creep . The method is not an absolute one and necessitates calibration with solutions of accurately known (n - hq), so that the calibration constant k can be determined for the apparatus ... [Pg.2025]


See other pages where Cells differential temperature is mentioned: [Pg.173]    [Pg.235]    [Pg.365]    [Pg.225]    [Pg.218]    [Pg.348]    [Pg.443]    [Pg.444]    [Pg.23]    [Pg.348]    [Pg.444]    [Pg.583]    [Pg.86]    [Pg.72]    [Pg.217]    [Pg.101]    [Pg.427]    [Pg.509]    [Pg.55]    [Pg.288]    [Pg.379]    [Pg.15]    [Pg.232]    [Pg.123]    [Pg.331]    [Pg.133]    [Pg.1004]    [Pg.10]    [Pg.2848]    [Pg.502]    [Pg.712]    [Pg.486]    [Pg.12]    [Pg.692]   
See also in sourсe #XX -- [ Pg.14 ]




SEARCH



Cell differentiation

Cell differentiation cells)

Differentiated cells

Temperature cells

Temperature differential

© 2024 chempedia.info