Minimum Uploading Concentration and Cell Detection Concentration... [Pg.551]

Path length (m) Absorbence Minimum Detectable Concentration (ppm) " (20 metre cell)... [Pg.336]

It is instructive to compare the sensitivity which may be achieved by absorption and fluorescence methods. The overall precision with which absorbance can be measured is certainly not better than 0.001 units using a 1 cm cell. Since for most molecules the value of emax is rarely greater than 105, then on the basis of the Beer-Lambert Law the minimum detectable concentration is given by cmin> 10 3/105= 10 8M. [Pg.732]

The flow sensitivity of a detector will also be one of the factors that determines the long term noise and thus will influence the sensitivity or minimum detectable concentration of the detector.lt is usually measured as the change in detector output for unit change in flow rate through the sensor cell. Again, the refractive index detector is the most sensitive to flow rate changes. [Pg.165]

Studies of the effects of in vitro exposure to a range of concentrations (encompassing environmentally relevant concentrations of monobutyltin, dibutyltin, and tributyltin) on human natural killer lymphocytes obtained from adult male and female donors revealed the presence of detectable concentrations of the butyltins in all the donors, indicating possible exposure of natural killer cells to butyltins in the blood. It was suggested that the study provided evidence that butyltin compounds significantly inhibit natural killer cell function and possible natural killer cell-mediated potential in humans (Whalen etal, 1999). [Pg.27]

The BioView sensor includes a software package (CAMO ASA, Norway) for data analysis and on-Une estimation of different bioprocess variables simultaneously. Thus, the instrument is able to predict the trends of the concentration courses of different variables during a cultivation and is used to give information about important process steps (e.g., feeding time, harvesting time, etc.). The instrument is able to monitor on-line several fluorophores in situ and non-invasively during cultivation processes and permits an estimation of different bioprocess variables simultaneously. The increasing of cell mass concentration and the product formation as well as the actual metabolic state of the cells is simultaneously detectable by this fluorescence technique. [Pg.30]

The human cell mutagenicities of several mono- and dinitropyrenes were determined by Busby and coworkers (1994b) in a forward mutation assay using a metabolically competent line of MCL-5 cells. Minimum detectable mutagen concentrations (MMC, in nmol ml-1 the smaller the detectable concentration, the greater the potency) were as follows 1,6-dinitropyrene, 0.8 1,8-dinitropyrene, 1.5 4-nitropyrene, 3.1 1-nitro-pyrene, 9.1. Other PACs tested, 2-nitropyrene, 1,3-dinitropyrene, and pyrene, were nonmutagens in this... [Pg.485]

Detectable concentrations of various antibacterials in milk attained by different microbiological tests are presented in Table 27.2. Milk constitutes a matrix that, apart from heating to destroy natural inhibitory substances, does not generally necessitate further sample treatment. Some antibiotics, however, exhibit some instability to heat treatment (54-56) and, therefore, if further confirmation is required reference frozen samples should always be available. When raw milk is directly analyzed, critical evaluation is generally required because natural inhibitors such as somatic cells, immunoglobulins, and metabolites may cause zones of inhibition (56, 57). Furthermore, several factors including marked pH-devia-tions, use of paper disks that contain inhibitory substances, and work with forceps that are too hot or have not been cleaned properly can readily lead to falsepositive readings (56, 58). [Pg.806]

A reorganization of microtubules and actin fibrils occurs, probably in response to an altered gradient of Ca2+. The morphology of the cells changes, and they begin immediately to crawl toward the chemoattractants. It appears that these ameboid cells detect a gradient of attractant concentration between one end of the cell... [Pg.1122]

Lucifer Yellow probes are water-soluble to at least 1.5%. The absorbance maximum of the derivatives occurs at about 426—428 nm with an emission peak at about 530—535 nm, in the yellow region of the spectrum. The quantum yield of Lucifer dyes is about 0.25. The good intensity of luminosity from these dyes makes possible detection of small quantities of labeled molecules intracellularly. The fluorescent conjugates are readily visible in living cells at concentrations that are nontoxic to cell viability. The low molecular weight and water solubility of these dyes allow passage of labeled compounds from one cell to another, potentially revealing molecular relationships... [Pg.379]

A121a cells were exposed to paclitaxel at concentrations of 0.2, 0.8, 2, and 5 ng/mL. Paclitaxel uptake by cells was able to be quantified at each time point under four treatment conditions. The lowest measured intracellular accumulation was 6.5 pg/106 cells, observed 10 min after the addition of 0.2 ng/mL paclitaxel to cells. The detected concentration in this sample corresponded to approximately 9.6 pg/mL drug in the cell lysate, which is nearly twice the LOQ. Foremost concentrations of paclitaxel, it appeared that the intracellular drug concentrations increased rapidly with exposure time and reached a plateau within 1-3 h. However, for cells exposed to the lowest concentration (0.2 ng/mL), the maximum intracellular drug concentration apparently was not achieved within 6 h, which was longest time interval investigated. In future studies, these data will be expanded to include additional concentrations and exposure times, and analyzed according to cellular pharmacokinetic models such as those published previously [12],... [Pg.100]

We now brought our chemist, T. Krigas, in to isolate and identify these products. He clearly identified it as a platinum-containing compound, probably ammonium chloroplatinate [NH4]2[PtCl6]. We were somewhat nonplussed, however, when addition of this compound at the detected concentration to bacterial cells in test-tube cultures led, not to filamentation, but to bacteriocidal activity. Many experiments later we found that a solution of this compound, after standing on our laboratory shelf for a few weeks, was able to produce a small amount of short filaments. [Pg.9]

However, a detectivity of 10 9 g/mL for a concentration detector means that this concentration is the smallest one that can be detected at that concentration in the detector cell. Consequently if a sample of this concentration is introduced into a chromatograph and run, its concentration will be somewhat less when it reaches the detector, because we have seen that an analyte is diluted and its zone becomes wider as it passes through the column. Thus, the amount of analyte that can actually be run and detected can differ from the MDQ. This situation has produced other terms like minimum detectable concentration, MDC, which will depend on the peak width (in milliliters). Analogously, for the mass flow rate detectors, the minimum detectable mass, MDM, will depend on the peak width in time units. In both cases, the quantity to be injected depends on... [Pg.205]

There are other examples of the influence of PolyPs on the expression of some genes omitting rpoS. If the level of cellular PolyP in E. coli was reduced to a barely detectable concentration by overproduction of exopolyphosphatase (Shiba et al., 1997), the cells were more sensitive to UV or mitomycin C than the control cells. PolyP accumulation was observed after treatment with mitomycin C, whereas the PolyP level was below the detectable level... [Pg.109]


See other pages where Cell detection concentration is mentioned: [Pg.550]    [Pg.550]    [Pg.334]    [Pg.312]    [Pg.163]    [Pg.414]    [Pg.415]    [Pg.416]    [Pg.418]    [Pg.334]    [Pg.302]    [Pg.425]    [Pg.458]    [Pg.240]    [Pg.64]    [Pg.244]    [Pg.213]    [Pg.213]    [Pg.30]    [Pg.322]    [Pg.183]    [Pg.358]    [Pg.242]    [Pg.158]    [Pg.610]    [Pg.395]    [Pg.88]    [Pg.446]   