Detector capacitance

The pulse height can be computed if the capacitance, detector characteristics, and radiation are known. The capacitance is normally about 10 4 farads. The number of ionizing events may be calculated if the detector size and specific ionization, or range of the charged particle, are known. The only variable is the gas amplification factor that is dependent on applied voltage. [Pg.37]

Many devices for determining the level of a cryoliquid have been proposed there are acoustic, resistive and capacitive detectors. [Pg.134]

Fluorescence detection, because of the limited number of molecules that fluoresce under specific excitation and emission wavelengths, is a reasonable alternative if the analyte fluoresces. Likewise, amperometric detection can provide greater selectivity and very good sensitivity if the analyte is readily electrochemically oxidized or reduced. Brunt (37) recently reviewed a wide variety of electrochemical detectors for HPLC. Bulk-property detectors (i.e., conductometric and capacitance detectors) and solute-property detectors (i.e., amperometric, coulo-metric, polarographic, and potentiometric detectors) were discussed. Many flow-cell designs were diagrammed, and commercial systems were discussed. [Pg.129]

This includes drawn (intentional) capacitance, detector junction, and any stray capacitance. [Pg.217]

Figure C3.1.1. The basic elements of a time-resolved spectral measurement. A pump source perturbs tlie sample and initiates changes to be studied. Lasers, capacitive-discharge Joule heaters and rapid reagent mixers are some examples of pump sources. The probe and detector monitor spectroscopic changes associated with absorjDtion, fluorescence, Raman scattering or any otlier spectral approach tliat can distinguish the initial, intennediate and final... Figure C3.1.1. The basic elements of a time-resolved spectral measurement. A pump source perturbs tlie sample and initiates changes to be studied. Lasers, capacitive-discharge Joule heaters and rapid reagent mixers are some examples of pump sources. The probe and detector monitor spectroscopic changes associated with absorjDtion, fluorescence, Raman scattering or any otlier spectral approach tliat can distinguish the initial, intennediate and final...
The noise is expressed as noise density in units of V/(Hz), or integrated over a frequency range and given as volts rms. Typically, photoconductors are characterized by a g-r noise plateau from 10 to 10 Hz. Photovoltaic detectors exhibit similar behavior, but the 1/f knee may be less than 100 Hz and the high frequency noise roU off is deterrnined by the p—n junction impedance—capacitance product or the amplifier (AMP) circuit when operated in a transimpedance mode. Bolometers exhibit an additional noise, associated with thermal conductance. [Pg.422]

The primary reference method used for measuring carbon monoxide in the United States is based on nondispersive infrared (NDIR) photometry (1, 2). The principle involved is the preferential absorption of infrared radiation by carbon monoxide. Figure 14-1 is a schematic representation of an NDIR analyzer. The analyzer has a hot filament source of infrared radiation, a chopper, a sample cell, reference cell, and a detector. The reference cell is filled with a non-infrared-absorbing gas, and the sample cell is continuously flushed with ambient air containing an unknown amount of CO. The detector cell is divided into two compartments by a flexible membrane, with each compartment filled with CO. Movement of the membrane causes a change in electrical capacitance in a control circuit whose signal is processed and fed to a recorder. [Pg.196]

Generally two main types of foam detector are used. They work by detecting either changes in electrical capacitance or changes in electrical resistance. Table 4.2 shows the application of foam detectors based on various principles, such as conductance, thermal conductivity, capacitance, ultrasonic rotating disks. [Pg.78]

CCD detector designers try to increase the signal-to-noise ratio of an amplifier in two ways (1) increase the responsivity, or (2) decrease the random current fluctuation between source and drain. The responsivity can be increased by decreasing the amplifier size. Decreasing the amplifier size decreases the capacitance of the MOSFET. The responsivity of a MOSFET obeys the capacitor equation which relates voltage, V, to the charge Q on capacitance C V = QIC. [Pg.151]

Nonspectroscopic detection schemes are generally based on ionisation (e.g. FID, PID, ECD, MS) or thermal, chemical and (electro)chemical effects (e.g. CL, FPD, ECD, coulometry, colorimetry). Thermal detectors generally exhibit a poor selectivity. Electrochemical detectors are based on the principles of capacitance (dielectric constant detector), resistance (conductivity detector), voltage (potentiometric detector) and current (coulometric, polarographic and amperometric detectors) [35]. [Pg.179]

Another level detector is the capacitance gauge which relies on the difference of dielectric constant of liquid and vapour (1.057 and 1.001 for 4He). In most of these gauges, the capacitor is made of two concentric tubes. A review is reported in ref. [30],... [Pg.135]

Fig. 16.1. Capacitive transducer for resonant gravitational waves detectors. Fig. 16.1. Capacitive transducer for resonant gravitational waves detectors.
Microhotplates, however, are not only used for metal-oxide-based gas sensor applications. In all cases, in which elevated temperatures are required, or thermal decoupling from the bulk substrate is necessary, microhotplate-like structures can be used with various materials and detector configurations [25]. Examples include polymer-based capacitive sensors [26], pellistors [27-29], GasFETs [30,31], sensors based on changes in thermal conductivity [32], or devices that rely on metal films [33,34]. Only microhotplates for chemoresistive metal-oxide materials will be further detailed here. The relevant design considerations will be addressed. [Pg.6]

The photodiode array detector (PDAD) measures absorption of light waves by a sample. This is considered the most powerful of the ultraviolet spectrophotometric detectors. The optical system focuses light from a deuterium source through the sample flow cell onto several photodiodes. These act as capacitators by holding a fixed amount of charge. When light strikes the photodiodes, they discharge a certain amount of current. [Pg.21]

Two types of conductivity detectors exist the contact conductivity detector, where the electrodes are in direct contact with the electrolyte, and the contactless coupled conductivity detector (C D also called oscillometric detector). With this detector, two stainless-steel tubes that act as electrodes are mounted on a capillary at a certain distance from each other. By applying an oscillation frequency, a capacitive transition occurs between the actuator electrode and the liquid inside the capillary. After having passed the detection gap between the electrodes, a second capacitive transition between the electrolyte and the pickup electrode occurs (see Figures 7 and 8 which is an example of separation of cations). In different reviews, Zemann and Kuban and Hauser discuss the advantages of this technique which include rather simple mechanical parts and electronics, and Kuban et al. compared several C D detectors. This technique has also been used as a detector for analysis by microchip CE. C" D detectors are available to be mounted on existing CE instruments. [Pg.325]

Because the response time of the detector depends on the thermal time constant of the detector element / electrode assembly, coupled with the electrical time constant of the device capacitance and load resistor - the response versus modulation frequency (f shows a typical l//m form. [Pg.116]

Fluid-level detectors which use capacitive measurement ensure sufficient reagent and sample volumes. These detectors are integrated into the reagent probe and sample tip and require no maintenance. [Pg.40]


See other pages where Detector capacitance is mentioned: [Pg.6524]    [Pg.36]    [Pg.6523]    [Pg.6524]    [Pg.36]    [Pg.6523]    [Pg.2955]    [Pg.425]    [Pg.25]    [Pg.379]    [Pg.765]    [Pg.766]    [Pg.78]    [Pg.86]    [Pg.224]    [Pg.437]    [Pg.182]    [Pg.298]    [Pg.299]    [Pg.299]    [Pg.810]    [Pg.36]    [Pg.36]    [Pg.36]    [Pg.246]    [Pg.351]    [Pg.249]    [Pg.133]    [Pg.169]    [Pg.161]    [Pg.106]    [Pg.215]    [Pg.269]   