Internal calibrations

With the FT-ICR mass spectrometer it is possible to obtain high mass accuracy (about 1-5 ppm calibrated externally, 0.5-1-0 ppm if calibrated internally here an external calibration has been carried out using a tune mix containing compounds with m/z from... [Pg.190]

Decide which instmments can be calibrated internally and which have to be calibrated by subcontractors. [Pg.118]

A single measurement of a calibration sample can give the concentration of the test solution by a simple ratio. This is often done in techniques where a calibration internal standard can be measured simultaneously (within one spectrum or chromatogram) with the analyte and the system is sufficiently well behaved for the proportionality to be maintained. Examples are in quantitative nuclear magnetic resonance with an internal proton standard added to the test solution, or in isotope dilution mass spectrometry where an isotope standard gives the reference signal. For instrument responses As and /sample for internal standard and sample, respectively, and if the concentration of the internal standard is Cjs, then... [Pg.63]

The images are calibrated to the inner diameter of the 10-mm NMR tube, which is 8.9 mm [4]. The total volume for each cross-sectional slice is determined by first calculating the area of the coke bean, and then multiplying the area by the 300 pm slice thickness. The mean intensity was calculated, and the image intensity calibrated internally such that the brightest... [Pg.513]

Marty, B. 1992. Volcanic Fluxes of Volatiles. Preliminary Estimates Based on Rare Gas and Major Volatile Calibration. International Atomic Energy Agency, Vienna. [Pg.227]

Figure 6 Structures of some Pd-PEPPSI complexes used in this study. Rate of formation of 67 by using catalysts 29 ( ), 63 (m), 64 (a.) and PdCI (y control). Conversion was determined by using GC/MS against a calibrated internal standard (undecane)... Figure 6 Structures of some Pd-PEPPSI complexes used in this study. Rate of formation of 67 by using catalysts 29 ( ), 63 (m), 64 (a.) and PdCI (y control). Conversion was determined by using GC/MS against a calibrated internal standard (undecane)...
Three primary methods are used for calibration external standard calibration, internal standard calibration, and standard addition. Figs. 1-3 show the typical response curves for each method. [Pg.96]

Quantitative analysis using external calibration, internal standard calibration, and the method of standard additions are all possible with SPME. Calibration is discussed in Section 1.5.2 and at greater length in Chapter 2. [Pg.50]

Infrared spectra were obtained on a Digilab FTS-15/B spectrometer. Four hundred scans at a resolution of 2 cm l were signal averaged and the spectra were stored on a magnetic disc system. The frequency scale was calibrated internally with a helium-neon laser to an accuracy of 0.2 cm l. Spectra recorded at elevated temperatures were obtained using a SPECAC high temperature cell and controller mounted in the spectrometer. [Pg.809]

Quantification methods can be based on standard additions or external calibration. Internal standards may be used to correct for some losses of material but for many analyses suitable compounds are unavailable. In LC-MS and LC-MS/MS the ideal internal standards are stable isotope analogs of the target compounds as these behave exactly as the native compound used but can be distinguished by their different masses. For LSD-related compounds with slightly different structures such as methysergide have been used, but trideuterated LSD is available commercially. [Pg.4404]

The graph in Fig. 1 shows a separating efficiency measurement, in which the number of theoretical stages per metre is entered over the vapour load in the form of the F-factor. When the column packings are used with actual material systems, reference can be made to this calibration. Miniplant columns with calibrated internal fittings then make it possible to increase the scale of the equipment directly from the miniplant scale to the production scale. This offers the advantage of a fast and cost-effective process development. [Pg.156]

Calibration Internal standards Toluene-d8, fluorobenzene, 4-bromofluorobenzene, 1,2-dichloroethane-d4 Solvent for all standard solutions is methanol... [Pg.521]

Calibration Internal standard NDPA added to each... [Pg.597]

Calibration Internal standards Calibration range d-Naphthalene, 2,4,5-trichloroaniline Representing 5,30 and 100 ppm in the textile... [Pg.633]

Calibration Internal standard Range C labelled internal standards... [Pg.662]

Calibration Internal standard Calibration range Recovery and quantitation ISTDs 0.05-100 ng/mL... [Pg.677]

Calibration Internal standard Isotope dilution method, C-labelled... [Pg.697]

Calibration Internal standard THC-COOH-d9-HFBA-PFPOH... [Pg.738]

As with external calibration, internal calibration relies on the plotting of a response function over a given concentration range, then using the response function to establish the concentrations of the dosed samples in analytes. The fundamental difference between the two dosage methods is based on the fact that in internal calibration, a molecule (standard) is added systematically at a known concentration to the solution to be analyzed. [Pg.118]


See other pages where Internal calibrations is mentioned: [Pg.63]    [Pg.231]    [Pg.55]    [Pg.84]    [Pg.297]    [Pg.180]    [Pg.269]    [Pg.86]    [Pg.3]    [Pg.392]    [Pg.47]    [Pg.47]    [Pg.231]    [Pg.527]    [Pg.231]    [Pg.509]    [Pg.509]    [Pg.532]    [Pg.553]    [Pg.591]    [Pg.380]    [Pg.231]   
See also in sourсe #XX -- [ Pg.112 ]

See also in sourсe #XX -- [ Pg.235 ]

See also in sourсe #XX -- [ Pg.46 ]

See also in sourсe #XX -- [ Pg.117 ]




SEARCH



Calibration internal double-spike

Calibration internal standards used

Calibration of Internal Standard

Calibration of Internal Standard to Acyl-ACP

Calibration surrogate internal standard

Calibration volumetric internal standard

Calibration with an Internal Standard

Calibration with internal correction

High-resolution (a) raw data spectrum and (b) accurate masses calculated from internal calibration table

Inductively coupled plasma mass internal standard calibration

Instrument internal calibration

Internal calibrant

Internal calibrant

Internal calibration deposition

Internal calibration of PNP

Internal calibration tests

Internal calibrator

Internal calibrator

Internal mass calibration

Internal standard calibration

Isotope internal calibration

Isotope internal correction, calibration with

Primary Calibrants and Internal Standards