Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Box sizes

How large a simulation do we need Once more this depends on the system and properties of interest. From a spatial correlation fiinction (x(O)x(r) relating values computed at different points r apart, we may define a characteristic distance over which the correlation decays. The sumdation box size L should be significantly larger than in order not to influence the results. [Pg.2242]

If the simulated system uses periodic boundary conditions, the logical long-range interaction includes a lattice sum over all particles with all their images. Apart from some obvious and resolvable corrections for self-energy and for image interaction between excluded pairs, the question has been raised if one really wishes to enhance the effect of the artificial boundary conditions by including lattice sums. The effect of the periodic conditions should at least be evaluated by simulation with different box sizes or by continuum corrections, if applicable (see below). [Pg.9]

Prior to solvation, the solute is oriented according to its inertial axes such that the box size needed to accommodate it is minimized (minimizing the number of water molecules). The principal inertial axis is oriented along the viewer s Z axis, for example. Then water molecules are eliminated if any of the three atoms are closer to a solute atom than the contact distance you specify. [Pg.202]

External seals (Fig. 10-115) are installed with all seal components protected from the process fluid. The advantages of this arrangement are that (1) fewer critical materials of construction are required, (2) installation and setting are somewhat simpler because of the exposed position of the parts, and (3) stuffing-box size is not a hmiting factor. Hydraulic balancing is accomphshed by proper proportioning of the seal face and secondary seal diameters. [Pg.941]

Conduit size, wire, size, horsepower designation for motors, and trade sizes that do not reflect actual measurements, e.g., box sizes, will not be assigned dual designation SI units. [Pg.636]

Example 15.1 What will be the internal dimensions of a cold room to store 900 t of boxed frozen meat if the box size is 700 X 450 X 150 mm and the net weight 30 kg ... [Pg.170]

Box size for each PT (preferred adverse event term) is based on the nnmber of serious cases of the term across all drugs in the AERS database. Thus, the box size of each PT is stable over different displays of different drugs. [Pg.673]

Chemiefabrik in der Grojie eines Chips, Handdsblatt, May 1996 Vision of shoe box-sized micro reactors plant cells as model for micro-reactor development cost, performance, and safety advantages LIGA process numbering-up safety processing of hazardous substances [237]. [Pg.91]

There are several commercial packages that realise the above strategy for molecularly realistic systems. It is useful to discuss some of the limitations. Ideally, one would like to do simulations on macroscopic systems. However, it is impossible to use a computer to deal with numbers of degrees of freedom on the order of /Vav. In lipid systems, where the computations of all the interactions in the system are expensive, a typical system can contain of the order of tens of thousands of particles. Recently, massive systems with up to a million particles have been considered [33], Even for these large simulations, this still means that the system size is limited to the order of 10 nm. Because of this small size, one refers to this volume as a box, although the system boundaries are typically not box-like. Usually the box has periodic boundary conditions. This implies that molecules that move out of the box on one side will enter the box on the opposite side. In such a way, finite size effects are minimised. In sophisticated simulations, i.e. (N, p, y, Tj-ensembles, there are rules defined which allow the box size and shape to vary in such a way that the intensive parameters (p, y) can assume a preset value. [Pg.34]

From the above, one may be left with the impression that the MD technique has major problems. It is important to realise that there are relatively straightforward ways to systematically improve the method. In the future, the force fields will become more accurate, the computer power will increase and allow larger box sizes and longer (real-time) simulation times. Even today, MD simulations are the closest to this ideal situation as compared with other methods. [Pg.40]

This calculation is repeated over a range of box sizes, and a double - logarithmic plot of the lacunarity versns the size of the shding box is then produced. FracLac then outputs a text file containing the valnes of r and A for each image. [Pg.399]

The diaance term for all of the misclassified B samples is zero this indicates that the box size is not the problem. To graphically illustrate this point, a two-dimensioaal PCA plot for the class B samples is shown in Figure 4.74. It is clear that die class limits are adequate because the validation samples all fall within the boundary. The reason for the larger than expected F value for these four samples is the contribution from the PCA residual. However, the... [Pg.82]

For this example, the size of the box is manipulated to iliustrate a point. In general, the size of the box is set such that all samples arc correctly included and excluded during the validation phase. If the SIMCA model using a default box size includes samples from other classes, smaller bo.xcs can be used in an attemnt to cxc ui. e these antnles,... [Pg.84]

TABLE 4.23. Effect of Increasing the Box Size of Class C SMICA Model on Class A Samples = 1.2)... [Pg.263]

Distances between tube banks are of the order of 20 ft or so. A rough guide to box size is about 4cuft/sqft of radiant transfer surface, but the ultimate criterion is sufficient space to avoid impingement of flames on the tubes. Some additional notes on dimensions are stated with the design procedure of Table 8.18. [Pg.213]

COMMON BASE FOR PUMP AND MOTOR BY PACKING BOX TYPE - NO OF, BOXES — PACKING BOX SIZE OD - LENGTH... [Pg.788]

Information of the simulated systems the density, the box size, the dielectric... [Pg.166]

The four systems were simulated at T — 298K and were consisted of one /3-carotene molecule and 900 solvent molecules in a rectangular box with linear dimensions, which correspond to the solvent densities[49]. The solvent density, the box size, the dielectric constant and the normalized E Reichardt polarity [1] are shown in table 1. Note the variation of the dielectric constants of the selected solvents. These solvents also exhibit large variations of the normalized solvent polarity, changing from 0.006 (isopentane) to 0.762 (methanol) with the intermediate values of 0.355 (acetone) and 0.460 (acetonitrile)[42], The intermolecular interactions were described by the Lennard-Jones plus... [Pg.166]

Target Box size (A) No. of conformers3 Poses evaluated (millions) Poses savedc Best conformer found Best pose found6... [Pg.108]

FIGURE 2 Relationship between biological availability of autochthonously produced DOM (labile/recalcitrant) and (i) concentration in situ and (ii) uptake by heterotrophic microorganisms. Box sizes indicate ambient concentrations, whereas arrow thicknesses indicate transformation rates. [Pg.14]


See other pages where Box sizes is mentioned: [Pg.344]    [Pg.345]    [Pg.462]    [Pg.455]    [Pg.62]    [Pg.565]    [Pg.751]    [Pg.103]    [Pg.123]    [Pg.128]    [Pg.673]    [Pg.62]    [Pg.241]    [Pg.241]    [Pg.136]    [Pg.144]    [Pg.206]    [Pg.206]    [Pg.64]    [Pg.347]    [Pg.35]    [Pg.38]    [Pg.40]    [Pg.230]    [Pg.84]    [Pg.260]    [Pg.166]    [Pg.184]   
See also in sourсe #XX -- [ Pg.62 ]

See also in sourсe #XX -- [ Pg.62 ]




SEARCH



Fired heaters box size, rule

© 2024 chempedia.info