Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Automated mechanism analysis

One may determine the Tafel constants, orders of reaction with respect to each reactant and product, the response to potential pulse jabs, and the results of attempts to introduce higher values of a s in favor of a specific mechanism. These criteria can then be compared with expected trends for the types of reactions concerned. From such data, an r.d.s. can sometimes be worked out or the number of possible r.d.s. s reduced to two or three possible sequences can be determined. If one can reduce the possible r.d.s. s to a low number, it is often possible to devise specific tests to distinguish between them. Such distinction methods may include the analysis of predicted and determined isotopic effects. Further, sometimes an r.d.s. can be eliminated on the basis of model calculations of the heat of reaction impractical high values showing a pathway that is too difficult. [Pg.16]

The idea of automating experiments that are programmed to show up a behavior typical of certain mechanisms and pathways, having experiments being carried out in the control of a computer program, and then comparing the results with those calculated theoretically for each supposed model is attractive and reduces time demand greatly. [Pg.16]


Auger electron spectroscopy (AES), 787 Automated mechanism analysis in... [Pg.30]

Thermal analysis iavolves techniques ia which a physical property of a material is measured agaiast temperature at the same time the material is exposed to a coatroUed temperature program. A wide range of thermal analysis techniques have been developed siace the commercial development of automated thermal equipment as Hsted ia Table 1. Of these the best known and most often used for polymers are thermogravimetry (tg), differential thermal analysis (dta), differential scanning calorimetry (dsc), and dynamic mechanical analysis (dma). [Pg.149]

This chapter provides a complementary perspective to that provided by Kramer and Mah (1994). Whereas they emphasize the statistical aspects of the three primary process monitoring tasks, data rectification, fault detection, and fault diagnosis, we focus on the theory, development, and performance of approaches that combine data analysis and data interpretation into an automated mechanism via feature extraction and label assignment. [Pg.10]

Mathematical modeling of the cure process coupled with the automation of various thermal analytical instruments and Fourier Transform Infrared Spectroscopy (FT-IR) have made possible the determination of quantitative cure and chemical reaction kinetics from a single dynamic scan of the reaction process. This paper describes the application of FT-IR, differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) in determining cure and reaction kinetics in some model organic coatings systems. [Pg.377]

I-DEAS master series SDRC s mechanical design automation (MDA) software, used by manufacturers for the design, analysis, testing, and manufacturing of mechanical products. [Pg.608]

With the development of HPLC, a new dimension was added to the tools available for the study of natural products. HPLC is ideally suited to the analysis of non-volatile, sensitive compounds frequently found in biological systems. Unlike other available separation techniques such as TLC and electrophoresis, HPLC methods provide both qualitative and quantitative data and can be easily automated. The basis for the HPLC method for the PSP toxins was established in the late 1970 s when Buckley et al. (2) reported the post-column derivatization of the PSP toxins based on an alkaline oxidation reaction described by Bates and Rapoport (3). Based on this foundation, a series of investigations were conducted to develop a rapid, efficient HPLC method to detect the multiple toxins involved in PSP. Originally, a variety of silica-based, bonded stationary phases were utilized with a low-pressure post-column reaction system (PCRS) (4,5), Later, with improvements in toxin separation mechanisms and the utilization of a high efficiency PCRS, a... [Pg.66]

The character and the degree of automation in chemical control may have been covered in the above treatment of semi-automatic or completely automatic, and of discontinuous or continuous analysis, but something more should be said about the means by which automation proper has been performed in recent times. Whereas in the past automated analysis involved the use of merely, mechanical robots, to-day s automation is preferably based on computerization in a way which can best be explained with a few specific examples. Adjustment knobs have been increasingly replaced with push-buttons that activate an enclosed fully dedicated microcomputer or microprocessor in line with the measuring instrument the term microcomputer is applicable if, apart from the microprocessor as the central processing unit (CPU), it contains additional, albeit limited, memory (e.g., 4K), control logics and input and output lines, by means of which it can act as satellite of a larger computer system (e.g., in laboratory computerization) if not enclosed, the microcomputer is called on-line. [Pg.327]

Automatic analysis consists essentially of the same steps as the corresponding manual method (p. 4). In some cases this may be simple, the requirements amounting to a mechanical device for presenting the sample to the detector, a timer to control the time of measurement and a data recorder. However, if sample pretreatment and separations are necessary a variety of wet chemical stages needs to be automated. Such automated steps may be included in what remains essentially as an operator procedure. For... [Pg.516]


See other pages where Automated mechanism analysis is mentioned: [Pg.446]    [Pg.16]    [Pg.446]    [Pg.16]    [Pg.128]    [Pg.276]    [Pg.220]    [Pg.6]    [Pg.117]    [Pg.53]    [Pg.361]    [Pg.324]    [Pg.145]    [Pg.727]    [Pg.309]    [Pg.417]    [Pg.38]    [Pg.81]    [Pg.208]    [Pg.262]    [Pg.392]    [Pg.429]    [Pg.440]    [Pg.876]    [Pg.34]    [Pg.201]    [Pg.322]    [Pg.706]    [Pg.249]    [Pg.169]    [Pg.31]    [Pg.51]    [Pg.75]    [Pg.324]    [Pg.40]    [Pg.269]    [Pg.271]    [Pg.300]    [Pg.419]    [Pg.429]   
See also in sourсe #XX -- [ Pg.16 ]




SEARCH



Automated analysis

Mechanical analysis