API 3000 triple quadrupole mass spectrometer

Sample analysis was performed by using an Applied Biosystems (Foster City, CA) API 3000 triple quadrupole mass spectrometer equipped with a TurboIonSpray source and an Agilent 1100 capillary HPLC system (Palo Alto, CA). The capillary HPLC system included a binary capillary pump with an active micro flow rate control system, an online degasser, and a microplate autosampler. The analytical column was a 300 pm I.D.x 150 mm Zorbax C18 Stablebond capillary column (pore size 100 A and particle size 3.5 pm). The injection volume was 5 pL, and a needle ejection rate of 40 pL/min was used. The pLC flow rate was 6 pL/min. In order to minimize dead volume before the column, the autosampler was programmed to bypass the 8 pL sample loop 1.5 min after injection. The mobile phase consisted of (A) 2 mM ammonium acetate (adjusted to pH 3.2 with formic acid) in 10 90 acetonitrile-water, and (B) 2 mM ammonium acetate in 90 10 acetonitrile-water. The percentage of mobile phase B was held at 32 % for the first minute, increased to 80 % over 8 min, and then increased tol00% over the following 1 min. [Pg.85]

Instrumentation LC/MS/MS analysis is carried out on a Perkin-Elmer SCIEX API 3000 triple quadrupole mass spectrometer (Toronto, Canada) interfaced to an HPLC system consisting of a Perkin-Elmer Series 200... [Pg.469]

MS Detection The experiments were conducted on an API 3000 triple quadrupole mass spectrometer (Applied Biosystems, Foster City, CA) equipped with its Turbolonspray interface operated... [Pg.142]

Mass Spectrometry and Other Analytical Procedures. Liquid chromatography electrospray mass spectrometry (LC-ESMS) was performed on approximately 1 pg protein samples with a Perkin Elmer Sciex API-300 triple quadrupole mass spectrometer fitted with an articulated ion spray source and set to scan over a range of 400-3000... [Pg.440]

The LIT introduced as part of a triple-quadrupole mass spectrometer is marketed under the name QTRAP. As shown in Fig. 1.26, the ion path and the differentially pumped region of QTRAP are similar to a triple quadrupole (API 3000, API 4000, and API 5000), except the Q3 is capable of functioning as a linear trap. QTRAP and its capabilities are described in detail in Chapter 3. Table 1.2 compares some of the advantages and limitations of QTRAP and LTQ mass spectrometers. [Pg.41]

Figure 1.14. MRM chromatograms of SCH 29851 (383.0. 337.0) and SCH 34117 (311.1 259.1) obtained using Sciex API 3000 (triple-stage quadrupole) and Sciex QSTAR pulsar (Q-TOF). Comparison of MRM chromatograms of SCH 29851 and SCH 34117 obtained at the LOQ (1 ng/mL) using the API 3000 mass spectrometer with those from the Q-TOF mass spectrometer indicated that the S/N ratio is at least 10-20 times better on the API 3000 mass spectrometer. However, the MRM chromatograms from the API 3000 mass spectrometer do not provide the option to further examine the MS/MS spectra whereas the full-scan MS/MS spectra from a Q-TOF based quantitative bioanalysis assay allows one to easily eliminate any questions about false-positive data. (Rephnted with permission from Yang et a ., 2001b.)... Figure 1.14. MRM chromatograms of SCH 29851 (383.0. 337.0) and SCH 34117 (311.1 259.1) obtained using Sciex API 3000 (triple-stage quadrupole) and Sciex QSTAR pulsar (Q-TOF). Comparison of MRM chromatograms of SCH 29851 and SCH 34117 obtained at the LOQ (1 ng/mL) using the API 3000 mass spectrometer with those from the Q-TOF mass spectrometer indicated that the S/N ratio is at least 10-20 times better on the API 3000 mass spectrometer. However, the MRM chromatograms from the API 3000 mass spectrometer do not provide the option to further examine the MS/MS spectra whereas the full-scan MS/MS spectra from a Q-TOF based quantitative bioanalysis assay allows one to easily eliminate any questions about false-positive data. (Rephnted with permission from Yang et a ., 2001b.)...

See other pages where API 3000 triple quadrupole mass spectrometer is mentioned: [Pg.310]    [Pg.346]    [Pg.604]    [Pg.629]    [Pg.310]    [Pg.346]    [Pg.604]    [Pg.629]    [Pg.166]   
See also in sourсe #XX -- [ Pg.142 ]