Another calibration

We are leaving this application as an exercise for you, dedicated reader. Table 5A.6 shows the zinc ion concentrations of aqueous solutions and their [Pg.243]


The calibration graph should cover the dilution range likely to be used in the determination of the concentration of the unknown solution. If the solution of unknown concentration has an absorbance value outwlth those used in the calibration graph, another calibration graph should be prepared using more appropriate concentrations of the standard solutions. [Pg.89]

Another calibration technique - standard addition - minimizes matrix effects because analytes with well defined increasing concentrations are added to a set of sample solutions to be analyzed. The measured calibration curve in the standard addition mode plots the measured ion intensities of analytes versus the concentration added to the sample solution. The concentration of analytes in the undoped sample is then determined by extrapolation of the calibration curve with the x-axis. Matrix matching is subsequently performed and the matrix effects (signal depression or interference problems) are considered. An example of the standard addition technique is described in Section 6.2.6 using solution based calibration in LA-ICP-MS. [Pg.194]

Inject 20pi of the calibration solution until the peak areas (or heights) of two successive injections agree to within 5%. Inject the sample solution. The peak area (or height) for the sample solution must not differ by more than 20% from the peak area (or height) for the deltamethrin calibration solution. If it differs, adjust the volume of the sample to meet this requirement or prepare another calibration solution with an adapted deltamethrin content. If not, inject the calibration solution and the sample solution in duplicate. [Pg.59]

Two-Dimensional Position Sensitive DACecCor, Calibration. A number of tests were performed to assure the accuracy ot the data collected by the system. These Included testing the detector uniformity to Insure that all the photo-diodes on the chip are of equivalent sensitivity. Another calibration of the device was to determine the magnifying affects of the camera. This was done to allow conversion of the x-y pixel grid Into the dimensions of reciprocal space. Finally, the contrast setting was adjusted so that a S6 value of 0 was produced when the screen was not Illuminated, with the gain set at maximum and the f-stop wide open. Further details of the system calibration can be found In Effler s M.S. thesis (17). [Pg.231]

When the piston reaches the extreme downstream portion of the flow tube, a motor driven ball valve in the return line is opened and the gas is returned to the upstream side of the sealed piston while the piston is being moved to its original starting position. It is then ready for another calibration run. [Pg.177]

The main requirement in the use of membranes in the construction of oxygen sensors is that the membrane must be permeable to oxygen, while restricting the passage of water and electrolyte. On this basis, the use of a single point calibration method based on the use of air, with the assumed linearity of response for other measurement, is feasible. Another calibration method involves the use of solutions previously verified by the Winkler oxygen titrimetric method. [Pg.88]

Description As soon as measurement conditions have been changed, it is a matter of reproducibility and no longer of repeatability. This is valid for the same individual sample measured under altered conditions (e.g., another day, another calibration, another operator), and also the measurement of different subsamples under the same or under varying conditions. Reproducibility may also be expressed in terms of dispersion characteristics of the result (e.g., standard deviation) and is often referred to as external standard deviation. [Pg.142]

The major drawback ofthis method is that since transitions are very temperature specific, one substance might be suitable for only one temperature range, hence the need to use more than one calibrant (or one must assume that the calibration will hold for the entire range being studied). Another calibration method is with the use of radioactive materials... [Pg.9]

However another calibration technique is available when the Calvet type DSC is used. The principle is to apply a known amount of power in a dedicated calibration vessel. To reach this target, a resistance is embedded in the crucible. A known current I is delivered and the corresponding tension U measured, providing the power P = UI that is applied. The corresponding Joule effect provides a DSC exothermic deviation in microvolt (Fig. 2.8). Such an electrical calibration is very interesting as it can apply at any temperature, even at constant temperature. This will be more detailed in paragraph 5 for the calorimetric techniques. [Pg.61]

The most important ingredient in ELF seems to be the curvature of the Fermi hole (respectively the value of Pauli kinetic energy density). However, the respective functions itself do not show the rich structure so typical for ELF. It is exclusively the calibration with respect to the unifonn electron gas that generates all the desired features. Thus, the ELF values depend on the function used for the calibration, which was arbitrarily chosen to be the kinetic energy density of the uniform electron gas. This arbitrariness of the choice was often criticized, e.g., by Bader [73]. Another calibration function was examined by Ayers [54]. He used nearly free electron gas, but found the results much less satisfactory. [Pg.136]

Cleveland et al. [225, 226] introduced another calibration method, which includes dimensional data but without the need to know the cantilever thickness. The Cleveland method requires knowledge of cantilever length L and width w, elastic modulus E, and density q of the cantilever material. From the measured resonance frequency Vq, one can calculate the spring constant ... [Pg.70]


See other pages where Another calibration is mentioned: [Pg.122]    [Pg.156]    [Pg.247]    [Pg.355]    [Pg.134]    [Pg.234]    [Pg.291]    [Pg.92]    [Pg.274]    [Pg.345]    [Pg.243]    [Pg.57]    [Pg.76]    [Pg.213]    [Pg.171]    [Pg.96]    [Pg.169]    [Pg.11]   