Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analyzer repaired

To obtain a clear picture of larger, more complex, offline WT boilers, in addition to visual inspections, it is common practice to trepan or cut sections out of some of the tubes. The deposits found are weighed, reported as a weight per unit surface area, and analyzed. Repairs are then made to the tubes. [Pg.622]

Six independent groups of technical personnel provide prooftesting services. Prooftesting is performed by electricians, critical-metering mechanics, refrigeration mechanics, analyzer-repair technicians, instrument-maintenance personnel, and chemical process operators. [Pg.247]

Accident progression scenarios are developed and modeled as event trees for each of these accident classes. System fault trees are developed to the component level for each branch point, and the plant response to the failure is identified. Generic subtrees are linked to the system fault trees. An example is "loss of clcciric power" which is analyzed in a Markov model that considers the frequencies of lo,sing normal power, the probabilities of failure of emergency power, and the mean times to repair parts of the electric power supply. [Pg.418]

Set up a mechanism for analyzing service reports so as to determine response times, time to repair, and total downtime. [Pg.544]

In one incident, the laboratory staff were asked to analyze the atmosphere in a tanker to see if any hydrocarbon was present. The staff regularly analyzed the atmosphere inside LPG tank trucks to see if any oxygen was present. Owing to a misunderstanding they assumed that an oxygen analysis was required on this occasion and reported over the phone that "none had been detected." The worker assumed that no hydrocarbon had been detected and sent the tank truck for repair. Fortunately the garage carried out their own check analysis. [Pg.144]

Repair and maintenance records were analyzed to determine failure rates and distribution of failure modes. Preliminary findings are reported which include the Weibull distribution characteristics. Failure mode distributions are approximate. Overall mean-time-between-failure is given for the kiln, leach tank, screwfeeder, tank pump, tank gearbox, and kiln gearbox. The study was confined to an analysis of unscheduled repairs and failures. [Pg.54]

A passive film is stable in the region between the passivation and breakdown potentials if any part of the film is broken, it is rapidly repaired. Therefore it is necessary to derive a model that depicts the processes by which such local destruction and restoration are continuously repeated. This process can be regarded as a kind of nonequilibrium fluctuation concerning passivity. Using energetics, Sato7 analyzed such fluctuation processes as follows. [Pg.238]

If data will be summarized or analyzed as part of the protocol-defined statistical analysis, they should be cleaned first. Cleaned in this context means that erroneous data entered into a variable are repaired before data analysis. Under the direction of the statistics group, the data management group is responsible for cleaning the clinical data. [Pg.20]

The Polymerase Chain Reaction. In the past, a major drawback of hybridization assays was their need for relatively large amounts of sample DNA to compensate for their low sensitivity. This problem has been surmounted in recent years by the development of powerful enzymatic techniques that can exponentially replicate specific DNA sequences in the test tube. With these techniques it is now possible to analyze vanishingly small samples that initially contain fewer than 10 copies of the sequence of interest. The new methods take advantage of the chemical properties of nucleic acids and of highly specialized enzymes that can repair and replicate DNA in vitro. [Pg.225]

Field Sampling. An opportunity arose where actual field samples could be analyzed by both the infrared and gas chromatographic methods. At Robins AFB, Georgia, workers were inspecting and repairing the interior and exterior of C-141 aircraft fuel tanks. They were exposed only to JP-4 fuel fumes. Duplicate charcoal tubes or vapor monitors were attached to each worker, one on each lapel. Samples were drawn through the charcoal tubes at 0.20 to 0.26 1pm by portable pumps attached to the worker s belt. Because of slight variations, the total volumes collected for the duplicates were close, but not exactly the same in all cases. Samples were then labeled and shipped to our Laboratory for analysis by both methods. [Pg.41]

Why is the editing mechanism of the polymerase unable to achieve the necessary accuracy by itself why does it need the postreplicative mismatch repair mechanism The answer comes from analyzing the cost of editing. [Pg.535]

The MSI is used as a diagnostic criterion of replication errors caused by various mutations in at least five mismatch repair genes (Lynch and Smyrk, 1996). Therefore, MSI analysis is useful in clinical practice to identify patients with hereditary nonpolyposis colorectal cancer. Raedle et al. (1999) have presented a rapid DNA extraction method (rapid microsatellite analysis) for analyzing replication errors in paraffin-embedded tissues. [Pg.18]

Damage to analyzers and instrumentation from the intrusion of acid gases into the instrument air system was extensive. Repair costs were about 300,000. [Pg.155]


See other pages where Analyzer repaired is mentioned: [Pg.177]    [Pg.177]    [Pg.37]    [Pg.259]    [Pg.182]    [Pg.316]    [Pg.128]    [Pg.35]    [Pg.147]    [Pg.86]    [Pg.404]    [Pg.263]    [Pg.348]    [Pg.27]    [Pg.112]    [Pg.610]    [Pg.199]    [Pg.61]    [Pg.374]    [Pg.6]    [Pg.139]    [Pg.501]    [Pg.260]    [Pg.133]    [Pg.78]    [Pg.201]    [Pg.432]    [Pg.125]    [Pg.125]    [Pg.271]    [Pg.83]    [Pg.83]    [Pg.632]    [Pg.839]   
See also in sourсe #XX -- [ Pg.209 ]




SEARCH



Explosion Occurs after an Analyzer Is Repaired