Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical techniques water analysis

The most popular device for fluoride analysis is the ion-selective electrode (see Electro analytical techniques). Analysis usiag the electrode is rapid and this is especially useful for dilute solutions and water analysis. Because the electrode responds only to free fluoride ion, care must be taken to convert complexed fluoride ions to free fluoride to obtain the total fluoride value (8). The fluoride electrode also can be used as an end poiat detector ia titration of fluoride usiag lanthanum nitrate [10099-59-9]. Often volumetric analysis by titration with thorium nitrate [13823-29-5] or lanthanum nitrate is the method of choice. The fluoride is preferably steam distilled from perchloric or sulfuric acid to prevent iaterference (9,10). Fusion with a sodium carbonate—sodium hydroxide mixture or sodium maybe required if the samples are covalent or iasoluble. [Pg.138]

The variety of AES techniques requires careful evaluation for selecting the proper approach to an analytical problem. Table 4 only suggests the various characteristics. More detailed treatment of detection limits must include consideration of spectral interferences (191). AES is the primary technique for metals analysis in ferrous and other alloys geological, environmental, and biological samples water analysis and process streams (192). [Pg.318]

Sodium and chloride may be measured using ion-selective electrodes (see Electro analytical techniques). On-line monitors exist for these ions. Sihca and phosphate may be monitored colorimetricaHy. Iron is usually monitored by analysis of filters that have had a measured amount of water flow through them. Chloride, sulfate, phosphate, and other anions may be monitored by ion chromatography using chemical suppression. On-line ion chromatography is used at many nuclear power plants. [Pg.363]

Since 1970, new analytical techniques, eg, ion chromatography, have been developed, and others, eg, atomic absorption and emission, have been improved (1—5). Detection limits for many chemicals have been dramatically lowered. Many wet chemical methods have been automated and are controlled by microprocessors which allow greater data output in a shorter time. Perhaps the best known continuous-flow analy2er for water analysis is the Autoanaly2er system manufactured by Technicon Instmments Corp. (Tarrytown, N.Y.) (6). Isolation of samples is maintained by pumping air bubbles into the flow line. Recently, flow-injection analysis has also become popular, and a theoretical comparison of it with the segmented flow analy2er has been made (7—9). [Pg.230]

Visual inspection techniques are stressed as the most important tools used to study failures. This text is not a substitute for rigorous failure analysis conducted by experts, but it will help the reader identify and eliminate many cooling water system problems. Still, on occasion, the experienced, skilled, failure analyst using sophisticated analytical techniques and specialized equipment may be required to solve complex or unusual problems. Common sense, appropriate experience, and systematic investigation are, however, often superior to the more elaborate, but less effective, techniques used by some. [Pg.463]

A primary goal of this chapter is to learn how to achieve control over the pH of solutions of acids, bases, and their salts. The control of pH is crucial for the ability of organisms—including ourselves—to survive, because even minor drifts from the optimum value of the pH can cause enzymes to change their shape and cease to function. The information in this chapter is used in industry to control the pH of reaction mixtures and to purify water. In agriculture it is used to maintain the soil at an optimal pH. In the laboratory it is used to interpret the change in pH of a solution during a titration, one of the most common quantitative analytical technique. It also helps us appreciate the basis of qualitative analysis, the identification of the substances and ions present in a sample. [Pg.565]

High-resolution GC equipped with an appropriate detector is the most common analytical technique for determining the concentrations of 1,2-dibromoethane in air, water, wastewater, soil, leaded gasoline, and various foods (e.g., grains, grain-based foods, beverages, and fruits). The choice of a particular detector will depend on the nature of the sample matrix, the detection limit, and the cost of the analysis. Because volatile organic compounds in environmental samples may exist as complex mixtures or at very low concentrations, concentrations of these samples prior to quantification are... [Pg.100]

Early workers had to strnggle with serious lithium fractionation effects during mass spectrometric analysis. Today most workers use the multicollector sector ICP-MS technique first described by Tomascak et al. (1999). Improvements of the analytical techniques in recent years have lead to an accuracy better than 0.3%o. Unfortunately, there are no internationally accepted Li isotope values for rocks or waters. James and Palmer (2000) have determined nine international rock standards ranging from basalt to shale relative to the so-called NIST L-S VEC standard. [Pg.43]

Brand W (2002) Mass spectrometer hardware for analyzing stable isotope ratios. In P de Groot (ed.) Handbook of stable isotope analytical techniques. Elsevier, Amsterdam Brandriss ME, O Neil JR, Edlund MB, Stoermer EF (1998) Oxygen isotope fractionation between diatomaceous silica and water. Geochim Cosmochim Acta 62 1119-1125 Bremner JM, Keeney DR (1966) Determination and isotope ratio analysis of different forms of nitrogen in soils. III. Soil Sci Soc Am Proc 30 577-582 Brenninkmeijer CAM (1993) Measurement of the abundance of CO in the atmosphere and the and 0/ 0 ratio of atmospheric CO with applications in New Zealand and Australia. J Geophys Res 98 10595-10614... [Pg.234]

If the size of the literature is a reliable indicator, the analysis of compo-uents fotmd In nvironmfntnl samples has not been developed t the same extent as clinical applications of re versed-phase chromatography. More attention has been paid to the analysis of volatile species by gas phase chromatography. This is due in part to the difficulty in identifying large molecular weight complex molecules which are present in water at trace levels. However, determination of a variety of analytes in water, soil, or other matrices has been reported and the wider use of RPC in the evaluation of water quality especially can be expected. The apolar phases used in RPC may be a boon in the determination of dilute analytes. Frei (4M) has discussed how relatively unpolar compounds dissolved in water can be concentrated at the top of a reversed-phase column and then eluted as a narrow band with an appropriate solvent. This technique can be used for the analysis of environmental samples in which the analyte of interest is in exceedingly low concentration. [Pg.149]

S.2.2.2 ICLS Example 2 This example discusses the determination of sodium hydroxide (caustic) concentration in an aqueous sample containing sodium hydroxide and a salt using NIR spearoscopy. An example of this problem in a chemical process occurs in process scrubbers where CO, is converted to Na,CO and H,S is converted to Na,S in the presence of caustic. Although caustic and salts have no distinct bands in the NIR, it has been demonstrated that they perturb the shape of the water bands (Watson and Baughman, 1984 Phelan et al., 1989)-Near-infrared spectroscopy is therefore a viable measurement technique. This method also has ad tages as an analytical technique for process analysis because of the stability of the instrumentation and the ability to use fiber-optic probes to multiplex tlie interferometers and Icx ate them rcm< >tely from the processes. [Pg.297]


See other pages where Analytical techniques water analysis is mentioned: [Pg.301]    [Pg.9]    [Pg.134]    [Pg.324]    [Pg.174]    [Pg.357]    [Pg.244]    [Pg.836]    [Pg.837]    [Pg.408]    [Pg.18]    [Pg.130]    [Pg.144]    [Pg.748]    [Pg.12]    [Pg.1253]    [Pg.267]    [Pg.33]    [Pg.146]    [Pg.69]    [Pg.42]    [Pg.687]    [Pg.148]    [Pg.71]    [Pg.121]    [Pg.541]    [Pg.295]    [Pg.188]    [Pg.223]    [Pg.131]    [Pg.59]    [Pg.116]    [Pg.31]    [Pg.1253]    [Pg.749]    [Pg.243]    [Pg.255]    [Pg.334]    [Pg.437]    [Pg.437]   
See also in sourсe #XX -- [ Pg.24 ]




SEARCH



Analysis Analytical technique

Analysis techniques

Analytical Analyses

Analytical techniques

Water analysis

© 2024 chempedia.info