Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical fitting procedure

Model-fitting procedures are usually based on analytical solutions of the model however, model parameters may be estimated by fitting the differential equations describing the model. Since the numerical solution of the differential equations introduces another source of error, fitting of differential equations is usually limited to cases where nonlinearities are present. [Pg.91]

In this chapter, we have advocated the use of a computer for plotting the standard curve and performing the least squares fit procedure. Indeed, computers play a central role in the analytical laboratory for acquiring and manipulating data generated by instruments and for information management. [Pg.166]

The Ba of the motor-vehicle component appears to come mainly from diesel trucks. In part because of Its use as a smoke suppressant (14). Thus, the Ba associated with the component may be quite variable with time and traffic mix. If Br were Included, Its relative concentration In the component should probably be reduced by about 10% to account for losses of this volatile element between the time of release and Its collection at a receptor site. These elements could probably be used as markers If the fitting procedure had provision for weighting based on uncertainties of relative concentrations of elements In the components (21). For the present tests, we have not Included this feature, but have Included weighting factors of 1/a for each element In the samples, where a Includes uncertainties of the analytical measurements and filter blank values. If the additional weighting were Included, the Importance of Ba and Br In determining the strength of the motor-vehicle component would be reduced relative to that of Pb because of their greater uncertainties. [Pg.58]

With known analyte concentrations, the processed data provide calibration points, and Immusoft comprises fitting procedures to deduce the corresponding calibration curve that can be stored in the program for further experiments. Different calibration curves can be stored depending for instance on the assay protocol, on the specific features of the chip used or on the medium in which the assay is performed. In most cases, the calibration is performed with six independent chips of eight channels and cumulated in order to get a stable batch calibration. Then the results can be referred to this internal batch calibration. For routine control, one calibration each week is recommended to be sure that the chemistry is still in the specifications (e.g. + 10% of inter-assay standard deviation). [Pg.900]

Most recent data sets are accompanied by either estimates of errors of the measurements or observed sample-to-sample fluctuations which were entered into the library, as modern CMB programs (e.g., 13) use uncertainties of the source compositions and in ambient samples in weighted least-squares fitting procedures. Many older data sets do not include estimates of analytical errors or fluctuations of particle composition, so we attached estimates based on the... [Pg.298]

In the limit X—>oo we get the JKR equations, whereas in the opposite limit A—>0 the DMT equations are obtained. In practice, the JKR regime may be defined by the condition X>5 and the DMT regime by /L<0.1 [105]. In the intermediate range, the transition region, the M-D model has to be applied. The quasi-analytic M-D model, however, does not provide closed formulas and its application for curve-fitting procedures is rather cumbersome due to the fact that a system of equations has to be solved. This is why the development of a direct relation between force and contact deformation is a matter of current efforts [105-107]. [Pg.109]

As computers became faster, especially with the development of parallel and cluster computing, MD using direct dynamics became feasible. In direct dynamics, an analytic potential is never employed. Rather, the energy and its derivatives are computed as needed for each trajectory point. No error is introduced in a fitting procedure—the derivatives are accurately computed given the quantum mechanical method employed. [Pg.510]

This relation shows how the two-dimensional pressure may be determined through measurements of F at a sequence of equilibrium gas pressures F at a fixed temperature, either by graphical integration, or analytically, by curve fitting procedures. [Pg.299]

For common adsorbates the equilibrium constants of reactions involving only solution species are available from literature for less common adsorbates they can be determined in separate experiments that do not involve the adsorbent. The equilibrium constants of (hypothetical) surface reactions are the adjustable parameters of the model, and they are determined from the adsorption data by means of appropriate fitting procedure. With simple models (e.g. the model leading to Langmuir equation which has two adjustable parameters) the analytical equations exist for least-square best-fit model parameters as the function of directly measured quantities, but more complicated models require numerical methods to calculate their parameters. [Pg.586]

For all but the very smallest systems, (such as HeH and even there it is very expensive), it is not possible in practice to calculate the full potential surface, with a grid fine enough that it can be directly used for solving the (nuclear) dynamical problem in Van der Waals molecules (or for scattering calculations). Moreover, such a numerical potential would not be convenient for most purposes. Therefore, one usually represents the potential by some analytical form, for instance, a truncated spherical expansion (1) or another type of model potential (cf. sect. 2). The parameters in this model potential can be obtained by fitting the ab initio results for a limited set of intermolecular distances and molecular orientations. Since we have encountered some difficulties in this fitting procedure which we expect to be typical, we shall describe our experience with the ( 2114)2 and (N2)2 cases in some detail. At the same time, we use the opportunity to make a few comments about the convergence of the spherical expansion used for (Njjj and about the validity of the atom-atom model potential applied to both ( 2114)2 and (Njjx. [Pg.30]

Note that we have imitated Johnson s notation in which the quantity / is a constant factor that appears in the determination of the density p, and the parameters ro, and o are other parameters that are determined through the fitting procedure. Once the density function and the pair potentiai have been specified, fhe determination of the embedding function is complete in principle. In this case, because of the choice of functions, the relevant equations can be solved analytically with the result that the embedding energy is given by... [Pg.170]

Reference materials certified by international organizations are available for judging the accuracy of an analytical procedure. As far as NMR spectroscopy is concerned, systematic errors which are frequently related to the lack of accuracy arise mainly during the acquisition step and in the treatment of the FID s. In order to minimize bias in signal acquisition, oversampling and very stable decoupling procedures are recommended, and, to obtain very reproducible intensity values, an operator independent curve fitting procedure should be implemented in the analytical sequence. [Pg.510]


See other pages where Analytical fitting procedure is mentioned: [Pg.223]    [Pg.184]    [Pg.223]    [Pg.184]    [Pg.167]    [Pg.59]    [Pg.167]    [Pg.175]    [Pg.4]    [Pg.135]    [Pg.137]    [Pg.485]    [Pg.164]    [Pg.112]    [Pg.603]    [Pg.804]    [Pg.252]    [Pg.344]    [Pg.510]    [Pg.121]    [Pg.123]    [Pg.18]    [Pg.277]    [Pg.95]    [Pg.307]    [Pg.112]    [Pg.625]    [Pg.82]    [Pg.210]    [Pg.804]    [Pg.30]    [Pg.132]    [Pg.248]    [Pg.207]    [Pg.236]    [Pg.223]    [Pg.286]    [Pg.1060]    [Pg.2]    [Pg.247]   
See also in sourсe #XX -- [ Pg.184 ]




SEARCH



Analytic Procedures

Analytical Fitting

Analytical procedures

Fit Procedure

© 2024 chempedia.info