Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analyte quantitative analysis

DNA adducts with PAA, at concentrations of the order of 1 per 107 bases, can be determined after hydrolysis of the DNA to adducts such as 33 and 34 (Section n.B.2), by HPLC with tandem ESI-MS-MS detection. The LOD are in the order of 50 fmol on the column, for both analytes. Quantitative analysis of DNA adducts with PAA requires investigation of the MS of each individual adduct to be obtained after hydrolysis of DNA. For example, adducts 33 and 34, formed on enzymatic condensation of benzidine (7b) and 1-aminofluorene (10a) with adenine residues of DNA, can be determined by tandem ESI-MS-MS analysis, following the fragmentations depicted in 105 and 106, which gives optimum intensities when operating under suitable conditions. Additional support for the assignments can be obtained from adducts derived from deuteriated 7b and 10a28. [Pg.679]

There is a unique chapter on how to correctly use spectral processing to tackle the thorny problem of mixture analysis. Half the battle in obtaining a good infrared spectrum is proper sample preparation learn to win that battle by reading the Preparing Samples Properly chapter covering in detail the most important development in infrared sample preparation in decades diamond ATRs. The final chapters examine single analyte quantitative analysis and how infrared microscopy is used to catch criminals and solve industrial problems. [Pg.183]

It is relatively difficult to provide an exact quantitative analysis of compounds that are unstable and occur only in traces in foods. Serious errors are possible, particularly when the volatile flavor compounds are present in extremely small amounts, are unstable, and/or are reactive, and the workup conditions selected often result in considerable losses. It is known that quantitative results obtained for flavor compounds in foods can be significantly affected by the isolation method and the structure of the analyte. Quantitative analysis can readily give erroneous results, particularly when the internal standards that are used differ from the analytes in terms of their chemical and physical properties, as is usually the case. Although the method of quantifying volatile compounds with the aid of internal standards has been in use for quite some time, the literature repeatedly... [Pg.179]

This table lists values of /3, the cubical coefficient of thermal expansion, taken from Essentials of Quantitative Analysis, by Benedetti-Pichler, and from various other sources. The value of /3 represents the relative increases in volume for a change in temperature of 1°C at temperatures in the vicinity of 25°C, and is equal to 3 a, where a is the linear coefficient of thermal expansion. Data are given for the types of glass from which volumetic apparatus is most commonly made, and also for some other materials which have been or may be used in the fabrication of apparatus employed in analytical work. [Pg.1182]

Perhaps the most common type of problem encountered in the analytical lab is a quantitative analysis. Examples of typical quantitative analyses include the elemental analysis of a newly synthesized compound, measuring the concentration of glucose in blood, or determining the difference between the bulk and surface concentrations of Cr in steel. Much of the analytical work in clinical, pharmaceutical, environmental, and industrial labs involves developing new methods for determining the concentration of targeted species in complex samples. Most of the examples in this text come from the area of quantitative analysis. [Pg.9]

Current research in the areas of quantitative analysis, qualitative analysis, and characterization analysis are reviewed biannually (odd-numbered years) in Analytical Chemistry s Application Reviews. ... [Pg.10]

In a quantitative analysis, we measure a signal and calculate the amount of analyte using one of the following equations. [Pg.130]

Troost and Olavesen investigated the application of an internal standardization to the quantitative analysis of polynuclear aromatic hydrocarbons. The following results were obtained for the analysis of the analyte phenanthrene using isotopically labeled phenanthrene as an internal standard... [Pg.133]

Second, the majority of analytical techniques, particularly those used for a quantitative analysis, require that the analyte be in solution. Solid samples, or at least the analytes in a solid sample, must be brought into solution. [Pg.198]

In an ideal separation = I, Rj = 0, and Sj a = 0. In general, the separation factor should be approximately 10 for the quantitative analysis of a trace analyte in the presence of a macro interferent, and 10 when the analyte and interferent are present in approximately equal amounts. [Pg.203]

A sample contains a weak acid analyte, HA, and a weak acid interferent, HB. The acid dissociation constants and partition coefficients for the weak acids are as follows Ra.HA = 1.0 X 10 Ra HB = 1.0 X f0 , RpjHA D,HB 500. (a) Calculate the extraction efficiency for HA and HB when 50.0 mF of sampk buffered to a pH of 7.0, is extracted with 50.0 mF of the organic solvent, (b) Which phase is enriched in the analyte (c) What are the recoveries for the analyte and interferent in this phase (d) What is the separation factor (e) A quantitative analysis is conducted on the contents of the phase enriched in analyte. What is the expected relative erroi if the selectivity coefficient, Rha.hb> is 0.500 and the initial ratio ofHB/HA was lO.O ... [Pg.229]

In some situations the rate at which a precipitate forms can be used to separate an analyte from a potential interferent. For example, due to similarities in their chemistry, a gravimetric analysis for Ca + may be adversely affected by the presence of Mg +. Precipitates of Ca(01T)2, however, form more rapidly than precipitates of Mg(01T)2. If Ca(01T)2 is filtered before Mg(01T)2 begins to precipitate, then a quantitative analysis for Ca + is feasible. [Pg.240]

Quantitative Calculations The result of a quantitative analysis by particulate gravimetry is just the ratio, using appropriate units, of the amount of analyte to the amount of sample. [Pg.264]

Quantitative Analysis for a Single Analyte The concentration of a single analyte is determined by measuring the absorbance of the sample and applying Beer s law (equation 10.5) using any of the standardization methods described in Chapter 5. The most common methods are the normal calibration curve and the method of standard additions. Single-point standardizations also can be used, provided that the validity of Beer s law has been demonstrated. [Pg.400]

Minimizing Chemical Interferences The quantitative analysis of some elements is complicated by chemical interferences occurring during atomization. The two most common chemical interferences are the formation of nonvolatile compounds containing the analyte and ionization of the analyte. One example of a chemical interference due to the formation of nonvolatile compounds is observed when P04 or AP+ is added to solutions of Ca +. In one study, for example, adding 100 ppm AP+ to a solution of 5 ppm Ca + decreased the calcium ion s absorbance from 0.50 to 0.14, whereas adding 500 ppm POp to a similar solution of Ca + decreased the absorbance from 0.50 to 0.38. These interferences were attributed to the formation of refractory particles of Ca3(P04)2 and an Al-Ca-O oxide. [Pg.419]

Molecular fluorescence and, to a lesser extent, phosphorescence have been used for the direct or indirect quantitative analysis of analytes in a variety of matrices. A direct quantitative analysis is feasible when the analyte s quantum yield for fluorescence or phosphorescence is favorable. When the analyte is not fluorescent or phosphorescent or when the quantum yield for fluorescence or phosphorescence is unfavorable, an indirect analysis may be feasible. One approach to an indirect analysis is to react the analyte with a reagent, forming a product with fluorescent properties. Another approach is to measure a decrease in fluorescence when the analyte is added to a solution containing a fluorescent molecule. A decrease in fluorescence is observed when the reaction between the analyte and the fluorescent species enhances radiationless deactivation, or produces a nonfluorescent product. The application of fluorescence and phosphorescence to inorganic and organic analytes is considered in this section. [Pg.429]

Samples of analyte are dissolved in a suitable solvent and placed on the IR card. After the solvent evaporates, the sample s spectrum is obtained. Because the thickness of the PE or PTEE film is not uniform, the primary use for IR cards has been for qualitative analysis. Zhao and Malinowski showed how a quantitative analysis for polystyrene could be performed by adding an internal standard of KSCN to the sample. Polystyrene was monitored at 1494 cm- and KSCN at 2064 cm-. Standard solutions were prepared by placing weighed portions of polystyrene in a 10-mL volumetric flask and diluting to volume with a solution of 10 g/L KSCN in... [Pg.453]

Quantitative Analysis Using External Standards To determine the concentration of analyte in a sample, it is necessary to standardize the electrode. If the electrode s response obeys the Nernst equation. [Pg.486]

Quantitative Analysis Using the Method of Standard Additions Because of the difficulty of maintaining a constant matrix for samples and standards, many quantitative potentiometric methods use the method of standard additions. A sample of volume, Vx) and analyte concentration, Cx, is transferred to a sample cell, and the potential, (ficell)x) measured. A standard addition is made by adding a small volume, Vs) of a standard containing a known concentration of analyte, Cs, to the sample, and the potential, (ficell)s) measured. Provided that Vs is significantly smaller than Vx, the change in sample matrix is ignored, and the analyte s activity coefficient remains constant. Example 11.7 shows how a one-point standard addition can be used to determine the concentration of an analyte. [Pg.488]

Controlled-potential coulometry also can be applied to the quantitative analysis of organic compounds, although the number of applications is significantly less than that for inorganic analytes. One example is the six-electron reduction of a nitro group, -NO2, to a primary amine, -NH2, at a mercury electrode. Solutions of picric acid, for instance, can be analyzed by reducing to triaminophenol. [Pg.502]

Thus, the limiting current, is a linear function of the concentration of O in bulk solution, and a quantitative analysis is possible using any of the standardization methods discussed in Chapter 5. Equations similar to equation 11.35 can be developed for other forms of voltammetry, in which peak currents are related to the analyte s concentration in bulk solution. [Pg.514]

Correcting for Residual Current In any quantitative analysis the signal due to the analyte must be corrected for signals arising from other sources. The total measured current in any voltammetric experiment, itot> consists of two parts that due to the analyte s oxidation or reduction, and a background, or residual, current, ir. [Pg.521]

Amperometry is a voltammetric method in which a constant potential is applied to the electrode and the resulting current is measured. Amperometry is most often used in the construction of chemical sensors that, as with potentiometric sensors, are used for the quantitative analysis of single analytes. One important example, for instance, is the Clark O2 electrode, which responds to the concentration of dissolved O2 in solutions such as blood and water. [Pg.533]

Quantitative Calculations In a quantitative analysis, the height or area of an analyte s chromatographic peak is used to determine its concentration. Although peak height is easy to measure, its utility is limited by the inverse relationship between the height and width of a chromatographic peak. Unless chromatographic conditions are carefully controlled to maintain a constant column efficiency, variations in... [Pg.572]

The earliest examples of analytical methods based on chemical kinetics, which date from the late nineteenth century, took advantage of the catalytic activity of enzymes. Typically, the enzyme was added to a solution containing a suitable substrate, and the reaction between the two was monitored for a fixed time. The enzyme s activity was determined by measuring the amount of substrate that had reacted. Enzymes also were used in procedures for the quantitative analysis of hydrogen peroxide and carbohydrates. The application of catalytic reactions continued in the first half of the twentieth century, and developments included the use of nonenzymatic catalysts, noncatalytic reactions, and differences in reaction rates when analyzing samples with several analytes. [Pg.623]

A final requirement for a chemical kinetic method of analysis is that it must be possible to monitor the reaction s progress by following the change in concentration for one of the reactants or products as a function of time. Which species is used is not important thus, in a quantitative analysis the rate can be measured by monitoring the analyte, a reagent reacting with the analyte, or a product. For example, the concentration of phosphate can be determined by monitoring its reaction with Mo(VI) to form 12-molybdophosphoric acid (12-MPA). [Pg.625]

One important application of the variable-time integral method is the quantitative analysis of catalysts, which is based on the catalyst s ability to increase the rate of a reaction. As the initial concentration of catalyst is increased, the time needed to reach the desired extent of reaction decreases. For many catalytic systems the relationship between the elapsed time, Af, and the initial concentration of analyte is... [Pg.628]

If the rate is measured at a fixed time, then both k and are constant, and a calibration curve of (rate)f versus [A]o can be used for the quantitative analysis of the analyte. [Pg.630]

Noncatalytic Reactions Chemical kinetic methods are not as common for the quantitative analysis of analytes in noncatalytic reactions. Because they lack the enhancement of reaction rate obtained when using a catalyst, noncatalytic methods generally are not used for the determination of analytes at low concentrations. Noncatalytic methods for analyzing inorganic analytes are usually based on a com-plexation reaction. One example was outlined in Example 13.4, in which the concentration of aluminum in serum was determined by the initial rate of formation of its complex with 2-hydroxy-1-naphthaldehyde p-methoxybenzoyl-hydrazone. ° The greatest number of noncatalytic methods, however, are for the quantitative analysis of organic analytes. For example, the insecticide methyl parathion has been determined by measuring its rate of hydrolysis in alkaline solutions. [Pg.638]

Analytical and Test Methods. Gas chromatography is used for the quantitative analysis of malonates. Typical analysis conditions are 5% Reoplex 400 on Chromosorb G 80—100 mesh 2 m, 0.3 cm diameter metal column temperature for column = 120° C detector, 150°C and injector, 120°C. [Pg.467]


See other pages where Analyte quantitative analysis is mentioned: [Pg.212]    [Pg.296]    [Pg.450]    [Pg.212]    [Pg.296]    [Pg.450]    [Pg.262]    [Pg.2674]    [Pg.2]    [Pg.21]    [Pg.51]    [Pg.60]    [Pg.117]    [Pg.181]    [Pg.201]    [Pg.215]    [Pg.313]    [Pg.341]    [Pg.368]    [Pg.376]    [Pg.573]    [Pg.653]    [Pg.486]   
See also in sourсe #XX -- [ Pg.18 ]




SEARCH



Analyte quantitation

Analytical Analyses

Analytical Quantitation

© 2024 chempedia.info