Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analyte incorporation

Further research is required in this relatively new field to establish definitive data regarding differentiation between internal incorporation (ingestion) and external contamination (environmental), effect of hair type on analyte incorporation, time course of analyte appearance, dose vs. analyte concentration relationships, and the mechanism of drug entry into hair. Already this novel technique has proved useful in a wide variety of applications, and will unquestionably become more popular in future years. [Pg.177]

Fig. 21.2. Typical BET isotherm with specific analyte incorporation within the linear slope of the adsorption curve number of moles chloroform n in a QCM layer as a function of the partial pressure p. Fig. 21.2. Typical BET isotherm with specific analyte incorporation within the linear slope of the adsorption curve number of moles chloroform n in a QCM layer as a function of the partial pressure p.
Biomolecular immobilisation remains the primary challenge to commercialisation of immunosensors. Many successful sensors have been produced for numerous analytes, incorporating many different immobilisation methods, but most never make it past a laboratory, with very few ever making it to manufacturing prototypes. The transfer of a laboratory-based sensor to a mass-produced product while still retaining stabiUty, reUabil-ity and sensitivity requires simple and reproducible procedures. Complex multistep immobilisation procedures that require a trained operator to perform in a laboratory will not be easy to transfer to a manufacturing situation and would probably result in a poor quality product when compared to its laboratory-based prototype. [Pg.244]

The retention factor, k, is defined as the ratio of the number of analytes incorporated into the micelle, nic5 and that in the surrounding aqueous solution. [Pg.3019]

Nevertheless, further prerequisites for successfiil analyte inclusion/incorporation presumably must be fulfilled. Krueger et al. found clear proof for homogeneous analyte incorporation by using colored pH indicators [31], whereas HornefFer et al. have shown in a systematic study of different position isomers of dihydroxy-benzoic acids that only 2,5-DHB incorporates homogeneously and quantitatively, whereas other isomers such as 2,6-DHB do not incorporate at all, while some others incorporate only randomly [32]. Confocal laser scanning images of the protein avidin, labeled with the fluorochrome Texas Red for single crystals of... [Pg.5]

DHB and 2,6-DHB, are shown in Figure 1.1. No obvious correlation between analyte incorporation and the crystal structure of these isomers was found. [Pg.5]

Krueger, R., Pfenninger, A., Fournier, L, Gliickmann, M., and Karas, M. (2001) Analyte incorporation and ionization in matrix-assisted laser desorption/ ionization visualized by pH indicator molecular probes. Anal. Chem., 73, 5812-5821. [Pg.33]

The type and quality of solvents can influence the MALDI analysis of polymer samples. For example, the dryness and purity of tetrahydrofuran (THF) used to prepare polymer samples play a central role in the success of detecting high-molecular mass polymers [29]. The solvent system used can affect analyte incorporation and distribution in matrix crystals. As has been shown in MALDI biopolymer analysis, analyte distribution in matrix crystals can significantly affect the signal reproducibility, detection sensitivity, and relative intensities of individual components in a mixture [40]. However, unlike biopolymer analysis-where a... [Pg.320]

Risk-based analysis, described further in Ghapter 11, is defined as an approach to evaluation and decision-making that explicitly, and to the extent practical, analytically incorporates considerations of risk and uncertainty. Risk-based analysis shall be used to compare plans in terms of the likelihood and variability of their physical performance, economic success, and residual risks. A risk-based approach to water resources planning captures and quantifies the extent of risk and uncertainty in the various planning and design... [Pg.51]

The HORSM, HDMR, and EDSD-SVM approaches use MCS to estimate the underlying reliability. They may not be suitable for reliability evaluation of large structural systems where dynamic loadings need to be applied in time domain and several important features like PR coimections, several sources of nonlinearities and energy dissipation features must be explicitly analytically incorporated in the formulation satisfying the underlying physics. [Pg.3634]


See other pages where Analyte incorporation is mentioned: [Pg.113]    [Pg.216]    [Pg.155]    [Pg.1345]    [Pg.463]    [Pg.4]    [Pg.5]    [Pg.5]    [Pg.2033]    [Pg.2848]    [Pg.310]    [Pg.1294]   
See also in sourсe #XX -- [ Pg.4 , Pg.6 ]




SEARCH



Matrix analyte incorporation

© 2024 chempedia.info