Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensors amines

BORONIC ACID SUBSTITUTED SELF-DOPED POLY ANILINE [Pg.198]

4 Molecular Level Processing for Controlled Release ofRNA [Pg.199]


In this work the results of seai eh of sensor systems suitable for analysis of liquid and solid media for eontent of volatile aliphatie amines ai e presented. The most suitable proeedure of analysis is gas extraetion - deteetion . [Pg.331]

It has been demonstrated that dendrimers can be used also as fluorescent sensors for metal ions. Poly(propylene amine) dendrimers functionalized with dansyl units at the periphery like 34 can coordinate metal ions by the aliphatic amine units contained in the interior of the dendrimer [80]. The advantage of a dendrimer for this kind of application is related to the fact that a single analyte can interact with a great number of fluorescent units, which results in signal amplification. For example, when a Co ion enters dendrimer 34, the fluorescence of all the 32 dansyl units is quenched with a 32-fold increase in sensitivity with respect to a normal dansyl sensor. This concept is illustrated in Fig. 3. [Pg.187]

BIAlite system. Sensor Chip CMS, HBS buffer (lOmM H es, pH 7.4, 150 mM NaCl, 0.005% v/v surfactant p20 in distilled water), amine coupling kit were fi-om Pharmacia Biosensor (Uppsala, Sweden). [Pg.776]

PGIP, purified fi om P.vulgaris hypocotyls [11], was immobilized to the sensor ch via amine coupling. A continuous flow of HBS buffer (5 pl/min) was mantained over the sensor surface. The carboxylated dextran matrix of the sensor surface was first activated by a 6-min injection of a mixture of N-hydroxy-succinimide and N-ethyl-N - (3-diethylaminopropyl) carbodiimide, followed by a 7-min injection of PGIP (lOng/pl in 10 mM acetate, pH 5.0). Hie immobilization procedure was con leted by a 7-min injection of 1 M ethanolamine hydrochloride to block the remaining ester groups. [Pg.776]

The sensor ch consists of a glass de on to which a SO-nm thick gold film has been deposited. The gold film is then covered with a linker-layer to which a matrix of carboxylated dextran is attached. The dextran, which extends typically 100 nm out fi om the sur6ce, provides a hydrophilic, activatable and flexible polymer to which biomolecules can be coupled throu amine, sulphydryl, carboxyl and other groups. [Pg.777]

Probes based on macrocyclic amines include dansylamidoethylcyclen, which can detect zinc at sub-nanomolar concentrations and probes containing xanthene as the chromophore with an ideal wavelength range for intracellular studies.953,962 It is also important that the sensors can differentiate between the alkali metals, which are present at higher concentrations, and zinc. 2, 7-dichlorofluorescein-based sensors have been used in biological systems and reveal concentrations up to ca. 0.3 mM in hippocampal nerve synaptic vesicles.963... [Pg.1232]

Anon., CISHC Chem. Safety Summ., 1984, 55(218), 34-35 Diethylamine fumes from a reactor were usually absorbed in a glass scrubber through which sulfuric acid was circulated, but an unresolved fault in the level sensor caused the acid circulation pump to operate intermittently. While the pump was not running, amine fumes condensed in the dip pipe, forming a sohd crust (of the sulfate) which allowed a quantity of condensed amine to accumulate out of contact with the acid. When the pump was restarted, the neutralisation exotherm was sufficient to shatter the scrubber and distort the mesh guard around it. [Pg.1646]

Mohr G. Citterio D., Demuth C., Fehlmann M., Luzi J., Lohse C., Moradian A., Nezel T., Rothmaier M. Spichiger U.E., Reversible chemical reactions as the basis for optical sensors used to detect amines, alcohols and humidity, Journal of Materials Chemistry 1999 9 2259. [Pg.97]

Sensors for acidic (HC1, SO2, CO2, acetic acid) or basic gases (NH3, amines) often make use of pH indicator dyes immobilised in polymers. Lipophilic Bromophenol Blue (see section 4.2) dissolved in silicone is... [Pg.316]

D. Moscone, D. D Ottavi, D. Compagnone, G. Palleschi, and A. Amine, Construction and analytical characterization of Prussian Blue-based carbon paste electrodes and their assembly as oxidase enzyme sensors. Anal. Chem. 73, 2529—2535 (2001). [Pg.461]

Thioureas are most commonly prepared from reaction of isothiocyanates with amines. Also there are some reports on reactions of anime or carbodiimides with several thionating reagents. AA -Disubstituted thioureas bearing double NH groups have been developed as sensors, and as catalysts because of their hydrogen bonding ability. A,A -Disubstituted thiourea-linked sugar chains have been prepared by the reaction of isothiocyanate with amine. [Pg.160]

Advances have been achieved in recent years, such as the use of CL reagents as labels to derivatize and sensitively determine analytes containing amine, carboxyl, hydroxy, thiol, and other functional groups and their application in HPLC and CE [35, 36], the synthesis and application of new acridinium esters [37], the development of enhanced CL detection of horseradish peroxidase (HRP) labels [38], the use of immobilization techniques for developing CL-based sensors [39-42], some developments of luminol-based CL in relation to its application to time-resolved or solid-surface analysis [43], and the analytical application of electrogenerated CL (ECL) [44-47], among others. [Pg.59]


See other pages where Sensors amines is mentioned: [Pg.376]    [Pg.377]    [Pg.278]    [Pg.354]    [Pg.83]    [Pg.53]    [Pg.196]    [Pg.44]    [Pg.200]    [Pg.201]    [Pg.425]    [Pg.380]    [Pg.376]    [Pg.377]    [Pg.278]    [Pg.354]    [Pg.83]    [Pg.53]    [Pg.196]    [Pg.44]    [Pg.200]    [Pg.201]    [Pg.425]    [Pg.380]    [Pg.287]    [Pg.538]    [Pg.304]    [Pg.1219]    [Pg.1232]    [Pg.67]    [Pg.917]    [Pg.940]    [Pg.146]    [Pg.316]    [Pg.511]    [Pg.38]    [Pg.304]    [Pg.491]    [Pg.587]    [Pg.300]    [Pg.386]    [Pg.201]    [Pg.657]   
See also in sourсe #XX -- [ Pg.173 , Pg.182 , Pg.225 , Pg.313 ]




SEARCH



Chemical sensors amines

Sensors for Phenols and Amines

© 2024 chempedia.info