Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Allowable working pressures and

Each input source is protected by a PSV set no higher than the vessel s maximum allowable working pressure, and at least one of these PSVs cannot be isolated from the vessel. [Pg.403]

If more than one standard pipe size is indicated, calculate the wall thickness for each standard pipe size based on required maximum allowable working pressure and select a standard wall thickness for each -Size. [Pg.447]

The margin between the maximum allowable working pressure and the operating pressure must be considered in the selection of a rupture disk. [Pg.410]

Inspection and testing requirements are covered in detail. Most vessels are required to be hydrostatic-tested (generally with water) at 1.3 times the maximum allowable working pressure. Some enameled (glass-lined) vessels are permitted to be hydrostatic-tested at lower pressures. Pneumatic tests are permitted and are carried to at least IV4 times the maximum allowable working pressure, and there is provision for proof testing when the strength of the vessel or any of its parts cannot be computed with satisfactory assurance of accuracy. Pneumatic or proof tests are rarely conducted. [Pg.152]

Since these pressures (gas or vapor) are far above the maximum allowed working pressure, and even the test pressure of the reactor, the severity based on this criterion is rated as serious. ... [Pg.270]

Table L Comparison of Allowable Working Pressures and Weights for 3-Inch Steel High Pressure Pipe at 100 F... Table L Comparison of Allowable Working Pressures and Weights for 3-Inch Steel High Pressure Pipe at 100 F...
The first, 1914 edition of the ASME Code did basic things like defining the term maximum allowable working pressure, and defining the minimum allowable distance between rows of rivets. The 1914 Code stipulated that the maximum allowable pressure on cast iron boiler headers should not exceed 160 psig (about 10 atmospheres or 10 bar). Minimum capacities for boiler pressure relief valves were defined. [Pg.108]

These alloys are available in the cast form only. Pipe and fittings are cast with the upset ends being joined by split flanges. IntegraUy cast flanged pipe is also available. Allowable working pressures cannot be... [Pg.970]

Maximum Allowable Working Pressure -As defined in the construction codes for pressure vessels, the maximum allowable working pressure depends on the type of material, its thickness, and the service conditions set as the basis for design. The vessel or equipment may not be operated above this pressure, or its equivalent stress at any other metal, temperature. However, ANSI B31.3, Petroleum Refinery Piping Code, permits variations above the maximum allowable working pressure, as follows ... [Pg.116]

Manual Valve - Inadvertent operation of a block valve while the plant is onstream may expose equipment to a pressure that exceeds the maximum allowable working pressure. For the purpose of design, it is considered that only one manual valve is opened or closed and control devices are in their normal design position. A PR valve is required if the block valve is not locked or car sealed in the open position and if closure of such valve can result in overpressure. [Pg.136]

Pilot-operated valves have a pilot valve combined with the main valve. The spring of the main valve provides 75 percent loading on the disk and the remaining 25 percent is offered by the gas or vapor through the pilot valve. When the vessel reaches the maximum allowable working pressure, the pilot valve relieves the gas pressure, which contributes to the disk load. Thus the safety valve becomes wide open. This is illustrated in Figure 18. [Pg.319]

A 3,500-gal reaetor with styrene monomer undergoes adiabatie polymerization after being heated inadvertently to 70°C. The maximum allowable working pressure (MAWP) of the reaetor is 5 bar absolute. Determine the relief vent diameter required. Assume a set pressure of 4.5 bara and a maximum pressure of 5.4 bara. Other data and physieal properties are given as follows [12] ... [Pg.1002]

The design pressure for a vessel is called its Maximum Allowable Working Pressure (MAWP). In conversation this is sometimes referred to simply as the vessel s working pressure, The MAWP determines the setting of the relief valve and must be higher than the normal pressure of... [Pg.328]

Maximum allowable working pressure MAWP) Highest pressure to which the system can be subjected during operation. Thus, pressure is established by a relief device set pressure and must be less than or equal to the material strength limitations of equipment. This pressure e.stabli.sh-es piping class for fittings and pipe wall thickness requirements, both of which are discussed in Volume 1. [Pg.441]

Pressure relief must be adequate to prevent internal pressures from rising over 10% above the maximum allowable working pressure, except when the excess pressure is developed by external fire or other unforseen heat source. See design details in later paragraph. Papa [85] proposes an improved technique for relief sizing. Also see Figures 7-7A and 7-7B. [Pg.416]

When a pressure vessel is exposed to external heat or fire, supplemental pressure relieving devices are required for this excessive pressure. These devices must have capacity to limit the overpressure to not more than 21% above the maximum allowable working pressure of the vessel. (See Figures 7-7A and 7-7B.) A single relieving device may be used to handle the capacities of paragraph UG-125 of the code, provided it meets the requirements of both conditions described. [Pg.416]

The pressure at which the valve is expected to open (set pressure) is usually selected as high as possible consistent with the effect of possible high pressure on die process as well as the containing vessel. Some reactions have a rapid increase in temperature when pressure increases, and this may fix the maximum allowable process pressure. In other situations the pressure rise above operating must be kept to some differential, and the safety valve must relieve at the peak value. A set pressure at the maximum value (whether maximum allowable working pressure of vessel, or other, but insuring protection to the weakest part of the system) requires the smallest valve. Consult manufacturers for set pressure compensation (valve related) for temperatures >200°F. [Pg.425]

For a new installation, establish pressure vessel normal maximum operating pressure, and temperature, and then the safe increment above this for vessel design conditions and determine the maximum allowable working pressure (MAWP) of the new vessel. (Have qualified fabricator or designer establish this. See pretious discussion of topic.)... [Pg.438]

It is essential to select the type or style of rupture disk before making the final determination of the final burst pressure, and even this selection must recognize the pressure relationships between the disk s manufacturing range and the vessel s maximum allowable working pressure. (Also see Figures 7-31A and 31B.)... [Pg.456]

Safety valves are matched to a boiler s particular maximum allowable working pressure (MAWP), and a boiler failure may result if this pressure is greatly exceeded. Typically, boilers having more than 500 ft2 of surface area or exceeding more than 500 kW input are required to have two safety valves. [Pg.79]


See other pages where Allowable working pressures and is mentioned: [Pg.1024]    [Pg.116]    [Pg.847]    [Pg.327]    [Pg.328]    [Pg.1024]    [Pg.116]    [Pg.847]    [Pg.327]    [Pg.328]    [Pg.2318]    [Pg.7]    [Pg.406]    [Pg.117]    [Pg.319]    [Pg.6]    [Pg.399]    [Pg.421]    [Pg.425]    [Pg.455]    [Pg.399]    [Pg.421]    [Pg.425]    [Pg.455]    [Pg.191]   


SEARCH



Allowable Working Pressure and Temperature

Allowables

Allowances

Pressure work and

Pressure working

Work pressure

© 2024 chempedia.info