Adjusted length

Hotter and Balannec published one of the first real proposals to use SMB as a production tool for the pharmaceutical industry, and thus to scale down a process already used on a production scale [29]. The first commercially available plant (Licosep) SMB system was offered by Separex in 1991 and was exhibited for the first time in June 1991 during the Achema Exhibition. The system consisted of 24 stainless steel columns with adjustable lengths between a few centimeters up to almost 1 meter, HPLC pumps, and mulitpositional valves. To improve the robustness of the system, a rotary valve replaced two-way valves and the pumps were modified. [Pg.257]

Length of plume/cloud in a canyon (Ligure 2.15 Adjustment length for mean flow to adjust as it enters the porous canopy ... [Pg.85]

Case Trim mer. (Cartridges.) An implement or muchiiie, one or the other, used for trimming the mouths of shells for cartridges. These are im by a funnel to the tool, which has a knife to cut them to an adjusted length. [Pg.145]

From Eq. 6.26 we see that this is the number of pipe diameters needed to have the same friction loss as the fittings. Thus, the equivalent length is 1085[(3.068/ 12) ft] = 277 ft. Therefore, the adjusted length of the pipe is... [Pg.207]

Use a latex-free, adjustable length head strap - without the irritating staples to scratch wearers. [Pg.51]

L = adjusted length, m (add 30.5 m to length of belt between terminal pulleys for standard bearings add 46 m for antifriction bearings)... [Pg.503]

Eguchi A, Ochi M, Adachi N, Deie M, Nakamae A, Usman MA (2014) Mechanical properties of suspensory fixation devices for anterior cmciate ligament reconstruction comparison of the fixed-length loop device versus the adjustable-length loop device. Knee 21 743-748. doi 10. 1016/j.knee.2014.02.009... [Pg.220]

We shall see that adsorption can detect fractality only if Dp > D. A compact object Dp > D ) cannot penetrate in the smaller pores and one can picture the surface coverage as a tiling of the surface with objects of size R, The adjustable length is the size R. On the other hand, if Dp < Dp the fractal object adjust easily to the surface heterogeneity and is not equal to R, but to the size a of a subunit. [Pg.142]

Mismatched brake adjuster length. (393.47(c)) Defective Lining Conditions... [Pg.572]

A fimctional, easily assembled, operated and cleaned microbioreactor packed with immobilized Candida antarctica lipase B (Novozyme 435) was recently developed by Pohar et al. (2010). So far, microbioreactor was used for studying continuous mode ester synthesis within bis(trifluoromethylsulfonyl)imide - based ionic liquid media. Ionic liquid containing substrates was pumped into the microbioreactor at various flow rates, and at the outlet of the reactor the product was collected and analyzed. With fuUy adjustable length, width and depth, the developed packed bed microbioreactor was proven to be a very successful and versatile tooling for biocatalytic reactions such as isoamyl acetate or butyl butyrate synthesis (Cvjetko et al, 2010 Pohar et al., 2010). [Pg.693]


See other pages where Adjusted length is mentioned: [Pg.389]    [Pg.242]    [Pg.254]    [Pg.10]    [Pg.142]    [Pg.326]    [Pg.494]    [Pg.8]    [Pg.170]    [Pg.206]    [Pg.207]    [Pg.207]    [Pg.40]    [Pg.91]    [Pg.137]    [Pg.316]    [Pg.134]    [Pg.216]    [Pg.283]    [Pg.224]    [Pg.297]    [Pg.7]    [Pg.824]    [Pg.26]    [Pg.245]    [Pg.573]    [Pg.48]   
See also in sourсe #XX -- [ Pg.206 ]




SEARCH



Adjust the Tempo to Fill a Length of Time

Length adjustment

Length adjustment

Pulse, length adjustment