Adiabatic calorimeter class

In this context, the term adiabatic refers to calorimetry conducted under conditions that minimize heat losses to the surrounding environment to better simulate conditions in the plant, where bulk quantities of stored or processed material tend to minimize cooling effects. This class of calorimetry includes the accelerating rate calorimeter (ARC), from Arthur D. Little, Inc., and PHI-TEC from Hazard Evaluation Laboratory Ltd. [Pg.406]

The thermochemical study of photochemical or photochemically activated processes is not amenable to most of the calorimeters described in this book, simply because they do not include a suitable radiation source or the necessary auxiliary equipment to monitor the electromagnetic energy absorbed by the reaction mixture. However, it is not hard to conceive how a calorimeter from any of the classes mentioned in chapter 6 (adiabatic, isoperibol, or heat flow) could be modified to accommodate the necessary hardware and be transformed into a photocalorimeter. [Pg.147]

For cases where the secondary reaction plays a role (class 5), or if the gas release rate must be checked (classes 2 or 4), the heat release rate can be calculated from the thermal stability tests (DSC or Calvet calorimeter). Secondary reactions are often characterized using the concept of Time to Maximum Rate under adiabatic conditions (TMRad). A long time to maximum rate means that the time available to take risk-reducing measures is sufficient. However, a short time means that the... [Pg.261]

This brief overview of offline measurements can be concluded by considering the measurements of the heat released by chemical reactions, which can be obtained via calorimetric measurements [7, 18]. The most diffused industrial calorimeters are the so-called reaction calorimeters, basically consisting in jacketed vessels in which the reaction takes place and the heat released is measured by monitoring the temperature of the fluid in the jacket. A class of alternative instruments are the scanning calorimeters (differential or adiabatic), in which the analysis is performed by linearly increasing the sample temperature with respect to time, in order to test the reactivity of potentially unstable chemical systems in a proper temperature range by measuring the released heat. [Pg.35]

Heat accumulation calorimeters allow a rise in temperature of the reaction system for exothermic reactions or a decrease in temperature for endothermic reactions. A reaction is followed by measurement of a temperature change as a function of time, although modern calorimeters allow the signal to be converted into power. An adiabatic solution calorimeter is typical of this class. [Pg.137]