Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Additives, determination infrared spectroscopy

Mass spectrometry, infrared spectroscopy, and nuclear magnetic resonance spectroscopy are techniques of structure determination applicable to all organic molecules. In addition to these three generally useful methods, there s a fourth—ultraviolet (UV) spectroscopy—that is applicable only to conjugated systems. UV is less commonly used than the other three spectroscopic techniques because of the specialized information it gives, so we ll mention it only briefly. [Pg.500]

Frequently, electrochemical information can be interpreted better in the presence of additional nonelectrochemical information. Typically, however, there is one significant restriction electrochemical and spectroscopic techniques often do not detect exactly the same mechanisms. With spectroscopic measurements (e.g., infrared spectroscopy), products that are formed by electrochemical processes may be detected. In other cases (luminescence techniques) mechanisms may be found by which charge carriers are trapped and recombine. Other techniques (electroreflection studies) allow the nature of electronic transitions to be determined and provide information on the presence or absence of an electric field in the surface of an electrode. With no traditional technique, however, is it... [Pg.435]

Composition and structure of newly developed additives are commonly examined by IR, NMR, MS and elemental analysis, e.g. recently developed higher MW antioxidants [115]. Infrared spectroscopy is also well suited to the direct verification of compound composition and quantitative determination of additives in polymers. Gray and Neri [116] have used Soxhlet... [Pg.316]

Previous authors have taught the principles of solving organic structures from spectra by using a combination of methods NMR, infrared spectroscopy (IR), ultraviolet spectroscopy (UV) and mass spectrometry (MS). However, the information available from UV and MS is limited in its predictive capability, and IR is useful mainly for determining the presence of functional groups, many of which are also visible in carbon-13 NMR spectra. Additional information such as elemental analysis values or molecular weights is also often presented. [Pg.220]

Near-infrared spectroscopy is quickly becoming a preferred technique for the quantitative identification of an active component within a formulated tablet. In addition, the same spectroscopic measurement can be used to determine water content since the combination band of water displays a fairly large absorption band in the near-IR. In one such study [41] the concentration of ceftazidime pentahydrate and water content in physical mixtures has been determined. Due to the ease of sample preparation, near-IR spectra were collected on 20 samples, and subsequent calibration curves were constructed for active ingredient and water content. An interesting aspect of this study was the determination that the calibration samples must be representative of the production process. When calibration curves were constructed from laboratory samples only, significant prediction errors were noted. When, however, calibration curves were constructed from laboratory and production samples, realistic prediction values were determined ( 5%). [Pg.77]

Hiller and Funke obtained easily dissolvable linear macromolecules of PVS by anionic polymerization of 1,4-DVB up to conversions of 80-90% [230,231]. In these experiments very low concentrations of n-butyl lithium (n-BuLi) were used and tetrahydrofuran (THF) as solvent. The reactions were carried out at -78 °C and for 7 min. The contents of pendant vinyl groups in the polymer were determined by infrared spectroscopy, mercury-II-acetate addition and catalytic... [Pg.196]

Fourier transform spectroscopy technology is widely used in infrared spectroscopy. A spectrum that formerly required 15 min to obtain on a continuous wave instrument can be obtained in a few seconds on an FT-IR. This greatly increases research and analytical productivity. In addition to increased productivity, the FT-IR instrument can use a concept called Fleggetts Advantage where the entire spectrum is determined in the same time it takes a continuous wave (CW) device to measure a small fraction of the spectrum. Therefore many spectra can be obtained in the same time as one CW spectrum. If these spectra are summed, the signal-to-noise ratio, S/N can be greatly increased. Finally, because of the inherent computer-based nature of the FT-IR system, databases of infrared spectra are easily searched for matching or similar compounds. [Pg.150]

For characterization, the polymer is dissolved in methylene chloride, precipitated again in methanol and dried at 50 °C in vacuum.The limiting viscosity number is determined in tetrahydrofuran at 20 °C and the molecular weight calculated (see Sect. 2.3.3.3.1). Additional information can be obtained by infrared spectroscopy.There should be no absorption of the OH-group at -3400 cm . [Pg.280]

Figure 9.7 Vibrational energy levels determined from solution of the one-dimensional Schrodinger equation for some arbitrary variable 6 (some higher levels not shown). In addition to the energy levels (horizontal lines across the potential curve), the vibrational wave functions are shown for levels 0 and 3. Conventionally, the wave functions are plotted in units of (probability) with the same abscissa as the potential curve and an individual ordinate having its zero at the same height as the location of the vibrational level on the energy ordinate - those coordinate systems are explicitly represented here. Note that the absorption frequency typically measured by infrared spectroscopy is associated with the 0 —> 1 transition, as indicated on the plot. For the harmonic oscillator potential, all energy levels are separated by the same amount, but this is not necessarily the case for a more general potential... Figure 9.7 Vibrational energy levels determined from solution of the one-dimensional Schrodinger equation for some arbitrary variable 6 (some higher levels not shown). In addition to the energy levels (horizontal lines across the potential curve), the vibrational wave functions are shown for levels 0 and 3. Conventionally, the wave functions are plotted in units of (probability) with the same abscissa as the potential curve and an individual ordinate having its zero at the same height as the location of the vibrational level on the energy ordinate - those coordinate systems are explicitly represented here. Note that the absorption frequency typically measured by infrared spectroscopy is associated with the 0 —> 1 transition, as indicated on the plot. For the harmonic oscillator potential, all energy levels are separated by the same amount, but this is not necessarily the case for a more general potential...
Mossoba, M.M., Kramer, J.K.G., Fritsche, J., Yurawecz, M.P., Eulitz, K., Ku, Y., and Rader, J.I. 2001 a. Application of standard addition to eliminate conjugated linoleic acid and other interferences in the determination of total trans fatty acids in selected food products by infrared spectroscopy.. /. Am. Oil Chem. Soc. 78 631-634. [Pg.511]

Many studies use infrared spectroscopy for quality control and quality analysis in polymer production. It is particularly used for the determination of the composition of copolymers and polymer blends and also for determination of additive and filler contents [90, 91, 92]. [Pg.216]

The remaining useful life evaluation routine (RULER) is a useful monitoring program for used engine oils. The RULER system is based on a voltammetric method (Jefferies and Ameye, 1997 Kauffman, 1989 and 1994). The data allows the user to monitor the depletation of two additives ZDDP and the phenol/amineH+ antioxidant. The RULER results were compared to other standard analytical techniques, differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), total base number (TBN), total acid number (TAN), and viscosity to determine any correlation between the techniques (Jefferies and Ameye, 1997 and 1998). The test concluded that the RULER instrument can... [Pg.220]

The concentration of the siloxane introduced into the copolymer is most easily determined by proton NMR for soluble systems, as briefly referred to in Sect. 3.1. This was demonstrated by Summers et al. [45] and Arnold and coworkers [46-50], as well as Rogers et al. [52]. Others have routinely conducted these experiments to establish the copolymer composition. Infrared spectroscopy has been particularly useful for demonstrating the transformation of the amic acid, which is often an intermediate for the final imide form. The assignments have been noted in many of the polyimide reviews referred to earlier [1-8]. In addition, it is useful to conduct an elemental analysis for silicon as complementary proof of copolymer composition. Solid-state NMR can be used even for intractable polyimide systems to provide a good estimate of the copolymer composition. [Pg.76]


See other pages where Additives, determination infrared spectroscopy is mentioned: [Pg.9]    [Pg.49]    [Pg.555]    [Pg.190]    [Pg.82]    [Pg.311]    [Pg.260]    [Pg.40]    [Pg.315]    [Pg.401]    [Pg.610]    [Pg.196]    [Pg.152]    [Pg.42]    [Pg.180]    [Pg.188]    [Pg.841]    [Pg.242]    [Pg.267]    [Pg.383]    [Pg.254]    [Pg.46]    [Pg.193]    [Pg.230]    [Pg.87]    [Pg.65]    [Pg.263]    [Pg.166]    [Pg.693]    [Pg.138]    [Pg.168]    [Pg.14]    [Pg.227]    [Pg.192]    [Pg.235]    [Pg.1596]   
See also in sourсe #XX -- [ Pg.248 ]




SEARCH



Additives Infrared spectroscopy

Additives, determination

Additives, determination spectroscopy

© 2024 chempedia.info