Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Zero balance

There are unusual hazards associated with partial desolvation of crystalline solvated oxosalts, notably perchlorates. This may be because desolvation causes the oxygen balance to approach the zero balance point and maximum energy release potential. A similar effect has also been seen with an hydrated salt. [Pg.131]

Use HPLC grade solvent use freshly prepared eluent Fill with the same eluent Adjust zero balance... [Pg.28]

A calibration check of controllers should be made on a regular basis. The ISO 9000 standard reviews developing the frequency calibration checks. A visual examination should be made before proceeding with the check to determine that no damage exists. Some of the more common problems caused by a plant s hostile environment that can effect equipment such as sensors/transducers are noise interference, mounting holes (must be concentric and clean), installation, diaphragm considerations, and transducer calibration. Zero balance, full-scale sensitivity, and R-cal at 80% parameter reference points for calibration can be used. The sensor/transducer manufacturer provides these parameters.154... [Pg.176]

Set the bridge to zero the zero balance is adjusted with solvent on both thermistors by means of a potentiometer. For good reproducibility, the drop size should remain as uniform as possible. [Pg.513]

Place a small, zipper-closure plastic bag on the pan of a zeroed balance. Wearing gloves and using tongs, insert a 20- to 30-g piece of dry ice into the bag. [Pg.375]

After zero balancing the gauge circuits, a small, shallow hole is drilled through the geometric centre of the rosette. [Pg.367]

To solve this problem it is necessary to use zero balance radiometer with compensation of reflections between antenna and human body tissue. This principle is realized in most modem microwave radiometers An overview of microwave radiometry is given in a recent publication The balance multi-fiequency microwave radiometer has also been described These researchers used 5 frequencies in calculating the temperature profile in the brain. It is very important to use multi-frequency radiometer in order to visualize the temperature inside body. But the increase in tile munber of fiequencies increases the size and the weight of the radiometer and decreases the noise immunity of the device. The radiation from the human body is very small. So the noise immunity is one of the critical parameters of the microwave radiometer. [Pg.442]


See other pages where Zero balance is mentioned: [Pg.29]    [Pg.316]    [Pg.297]    [Pg.515]    [Pg.515]    [Pg.2511]    [Pg.270]    [Pg.650]    [Pg.515]    [Pg.515]    [Pg.3685]    [Pg.515]    [Pg.2420]    [Pg.239]    [Pg.282]    [Pg.308]    [Pg.414]    [Pg.553]    [Pg.581]    [Pg.5]    [Pg.345]    [Pg.346]    [Pg.391]    [Pg.291]    [Pg.655]    [Pg.223]    [Pg.161]   
See also in sourсe #XX -- [ Pg.581 ]




SEARCH



Zero nitrogen balance

Zero tracking, balances

© 2024 chempedia.info