Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Variation signals

A clue to the nature of the third itt MO can be found in the placement of electrons in the two resonance structures for ozone, which are shown with color highlights in Figure 10-36a. Notice that in one resonance structure, the left outer atom has three lone pairs and a single bond, while the right outer atom has two lone pairs and a double bond. In the other resonance structure, the third lone pair is on the right outer atom, with the double bond to the left outer atom. The double bond appears in different positions in the two stmctures, and one of the lone pairs also appears in different positions. These variations signal delocalized orbitals. [Pg.707]

The systematic variation (signal), which is associated with or is in response to changes in the predictors... [Pg.2269]

Anumber of defects with manual inspection indications clarified by AUGUR 4.2 records have been accepted for further operation in 1996 with prescription of next year AUGUR 4 2 inspection. Based on two consecutive inspections (1996-97 years) comparative analysis of AUGUR 4.2 data was executed. It was shown that the flaw configurations, reproduced by AUGUR 4.2 are stable and the small differences are conditioned only by system thresholds of linear coordinate and signal amplitude as well as variations in local conditions of in-site inspection. [Pg.196]

Fig. 1 shows the block diagram of the vibrometer, in which the most sensible to small phase variations interferometric scheme is employed. It consists of the microwave and the display units. The display unit consists of the power supply 1, controller 2 of the phase modulator 3, microprocessor unit 9 and low-frequency amplifier 10. The microwave unit contains the electromechanical phase modulator 3, a solid-state microwave oscillator 4, an attenuator 5, a bidirectional coupler 6, a horn antenna 7 and a microwave detector 11. The horn antenna is used for transmitting the microwave and receiving the reflected signal, which is mixed with the reference signal in the bidirectional coupler. In the reference channel the electromechanical phase modulator is used to provide automatic calibration of the instrument. To adjust the antenna beam to the object under test, the microwave unit is placed on the platform which can be shifted in vertical and horizontal planes. [Pg.655]

The CCF is sensitive to variations in all the signal parameters carrier frequencies, phases, pulse forms, durations and amplitudes. Both signal amplitudes A, and J in formula (1) can factor outside the integral sign and do not define its value. Hence we let the CCF as N= MIA or in normalized form N = NIN . ... [Pg.828]

So the correlative processing gives additional (to the amplitude) variation of output signal and makes the signal processing a multiparamctric one. Such processing increases the sensitivity and reduces the noises. [Pg.828]

After amplification both signals change their initial phases due to the delay r of the amplifier unblank (r = 0.1 - 0.5 ms), phase shift in it and wave propagation in passive vibrator s elements. All the mentioned phase changes are proportional to the frequency. The most contribution of them has unblank delay z. Thus frequency variations changes the initial phases) f/, and j(/c) of both signals and their difference A - Vi ... [Pg.828]

To increase the sensitivity, direction of amplitude variation of probe output signal in defective area must coincide with the one after CCF processing. If the defect decreases the probe signal (single contact probe) A((/should be set Ai// = 0, in the opposite case (twin contact probe) it should be set Aif/= n. So the instrument should be supplied with a device to adjust A((/ and to sustain it constant. [Pg.832]

By defining a norm defining the distance between two signals, one can easily spot its variations. This distance provides an image of the signal evolution. Signals are typically Lissajous ( orbits ), i.e. arrays 2 of successive complex-valued points... [Pg.1025]

SFIG or SFG from a medium that has a strong response in a separate detection anu. By this means, one may fiilly compensate for variations not only in pulse energy, but also in the temporal and spatial substructure of the laser pulses. Some experiments may require measurement of the phase of the nonlinear signal [57]. [Pg.1281]


See other pages where Variation signals is mentioned: [Pg.227]    [Pg.230]    [Pg.47]    [Pg.894]    [Pg.142]    [Pg.192]    [Pg.1149]    [Pg.104]    [Pg.382]    [Pg.161]    [Pg.227]    [Pg.230]    [Pg.47]    [Pg.894]    [Pg.142]    [Pg.192]    [Pg.1149]    [Pg.104]    [Pg.382]    [Pg.161]    [Pg.54]    [Pg.57]    [Pg.65]    [Pg.164]    [Pg.173]    [Pg.261]    [Pg.283]    [Pg.364]    [Pg.395]    [Pg.585]    [Pg.723]    [Pg.830]    [Pg.877]    [Pg.877]    [Pg.991]    [Pg.1023]    [Pg.1063]    [Pg.264]    [Pg.813]    [Pg.1284]    [Pg.1425]    [Pg.1475]    [Pg.1566]    [Pg.1716]    [Pg.611]    [Pg.116]    [Pg.179]    [Pg.49]    [Pg.384]    [Pg.468]   
See also in sourсe #XX -- [ Pg.433 ]




SEARCH



© 2024 chempedia.info