Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Valid function

If the comparison shows that the measurement is inconsistent with the comparison information, the measurement is considered suspecl. If a measurement can be compared to more than one set of information and found to be inconsistent with all, it is likely that the measurement is in error. The measurement should then be excluded from the measurement set. In this section, validation is extended to include comparison of the measurements to the constraints and initial adjustment in the measurements. Validation functions as an initial screening procedure before the more comphcated procedures begin. Oftentimes, vahdation is the only measurement treatment required prior to interpretation. [Pg.2566]

Thus, Staphylococcus aureus produces a golden yellow pigment, Serratia marcescens a bright red pigment. There appears to be no valid function for these pigments but they may afford the cell some protection from the toxic effects of sunlight. [Pg.10]

In summary, it is worthwhile to continue the installation of a vapor barrier that serves as the added valid function of moisture barrier. More comprehensive installation measures and more expensive materials may be merited in areas where the radon source is strong because of either high radon concentrations or high soil gas how rates. [Pg.1284]

Remark 2 Note that since x and y are not separable, then the GOS cannot provide theoretically valid functions in the general case, but only if the u(y) is convex (see v2-GBD). [Pg.137]

Qualification activities are usually undertaken in order to characterize a facility s services and utilities as well as the equipment that would be used as part of a manufacturing process. As indicated earlier, these activities will include installation and operational activities as part of the validation function. Most companies will issue a report that documents the features of the facility s processing rooms, such as the electrical, water, gas, and HVAC services, for the installation qualification. Table 5 is a generic outline of the items that would be found in the IQ report. Whenever the process equipment is permanendy fixed in these rooms, the report will also list the equipment as well as its operating requirements and features. See Table 6 for an outline of questions that would be used to complete a report, which includes equipment qualification. It is preferred that qualification occur as soon as the equipment or facility is ready for routine operation so that any unexpected results will be corrected by the equipment vendor and/or construction contractor. [Pg.800]

The discovery of MPTP as a potential toxin has precipitated three major lines of research first into the development of more valid functional animal models of human PD, which has been undertaken in particular in primates second, into the mechanisms of toxicity, studied particularly in mice and third, into the development of novel therapeutics from each of these first two lines of animal research, that are feeding back into developing clinical practice. [Pg.267]

Unfortunately, the partition coefficient is sensitive to the values of n independently of any structure in the data. We cannot therefore select the best fuzzy partition with C(P). A validity functional that is the dual of the... [Pg.338]

The elassification entropy may be interpreted as measuring the ambiguity assoeiated with a fuzzy partition. A good cluster identification would be indicated by an entropy value close to 0. Various transformations of the validity functionals C and E have been proposed to mitigate their monotonic tendencies. Here we consider a normalization that reduces the validity functional s range of variation to [0,1]. Normalized expressions of C and E assume the forms... [Pg.339]

S-Plus The validate ( ) function (19) is particularly appropriate for use during the QQ. As with NQNMEM, the system settings and systemwide user parameter files (20) should be identified and implemented during the IQ. As with any statistical package, it is highly recommended that appropriate statistical analyses from standards organizations (15) be utilized as appropriate to the organization. [Pg.66]

When a value is inserted into this table, the valid function will be called by the RDBMS. If the function returns true, then the value will be allowed into the column smi. Otherwise, an SQL error will be reported and the value will not be allowed. [Pg.86]


See other pages where Valid function is mentioned: [Pg.2]    [Pg.167]    [Pg.467]    [Pg.222]    [Pg.268]    [Pg.280]    [Pg.639]    [Pg.787]    [Pg.799]    [Pg.805]    [Pg.6]    [Pg.6373]    [Pg.6378]    [Pg.338]    [Pg.339]    [Pg.141]    [Pg.76]    [Pg.78]    [Pg.439]    [Pg.63]    [Pg.28]    [Pg.134]    [Pg.1255]    [Pg.117]    [Pg.133]    [Pg.445]    [Pg.6372]    [Pg.6377]    [Pg.483]    [Pg.146]    [Pg.146]    [Pg.105]   


SEARCH



Extension functions validation

Probability density function valid

Response function validation

Valid function SMILES

Validation Reviews Functional Specification

Validation functional control

Validation of Density Functionals

Validation of the Best Functions

Validation of the predicting function

Validity functionals

© 2024 chempedia.info