Uric acid detection

Uric acid (2,6,8-trihydroxypurine, UA) and other oxypurines are the principal products of purine metabolism. The normal concentration of UA in the urine of a healthy human is in the low millimolar range, whereas in the blood micromolar levels are normal. UA is electroactive and can be oxidatively detected, but a major problem is interference from other [Pg.225]

Marcel Dekker, Inc. 270 Madison Avenue, New York, New York 10016 [Pg.225]


Z. Wang, Y. Wang, and G. Luo, A selective voltammetric method for uric acid detection at (3-cyclodextrin modified electrode incorporating carbon nanotubes. Analyst 127, 1353-1358 (2002). [Pg.520]

Perez DM, Ferrer ML, Mateo CR (2003) A reagent less fluorescent sol-gel biosensor for uric acid detection in biological fluids. Anal Biochem 322 238-242... [Pg.148]

Another application of Zinc oxide nanostructure is immobilization of uricace onto ZnO nanorod and fabrication a sensitive biosensor for uric acid detection [167], The biosensor successfully used for micromolar detection of uric acid in the presence serious interferences, glucose, ascorbic acid, and 1-cysteine. The apparent KM value for the uric acid biosensor is 0.238 mM, showing high affinity of the biosensor. Direct electron transfer of SOD at a physical vapor deposited zinc oxide nanoparticles surface was investigated [168], In comparison to SOD immobilized onto ZnO nanodisks [169], the electron transfer rate constant is small and a quasi- reversible electrochemical behavior observed. A novel... [Pg.167]

Ascorbic Acid, Dopamine, and Uric Acid Detection... [Pg.1425]

T. Seki, K. Yamaji, Y. Orita, S. Moriguchi and A. Sliinoda, Simultaneous determination of uric acid and creatinine in biological fluids by column-switching liquid cliromatogra-phy with ulti aviolet detection , 7. Chromatogr. A 730 139-145 (1996). [Pg.294]

Thus, the presence of uric acid crystals in joints triggers a vicious cycle, resulting in an extremely painful inflammation. A typical localization of acute gouty arthritis is the first metatarsal joint of the foot (podagra). The diagnosis of acute gouty arthritis is confirmed by the detection of urate crystals in the joint or tophus. [Pg.136]

The detection limits per chromatogram zone are 100-200 ng for gallic acid andl aminophenazone [8, 14] and 10-15 ng for uric acid [6]. ... [Pg.165]

Mei, D.A., Gross, G.J., and Nithipatikom, K., Simultaneous determination of adenosine, inosine, hypoxanthine, xanthine and uric acid in microdialysis samples using microbore column liquid chromatography with diode array detection, Analyt. Biochem., 238,34,1996. [Pg.42]

Figure 15.14 illustrates a typical voltammetric result for the determination of dopamine in the presence of ascorbic acid with a CNT-modified electrode. The selective voltammetric detection of uric acid [82] or norepinephrine [83] in the presence of ascorbic acid has been demonstrated with a (3-cyclodextrin-modified electrodes incorporating CNTs. Ye et al. [84] have studied the electrocatalytic oxidation of uric acid and ascorbic acid at a well-aligned CNT electrode, which can be used for the selective determination of uric acid in the presence of ascorbic acid. The simultaneous determination of dopamine and serotonin on a CNT-modified GC electrode has also been described [85],... [Pg.500]

Kamei et al. [45] separated spermine, spermidine, putrescine, and cadav-erine in an ion-pair reversed-phase LC system and detected the hydrogen peroxide formed in the reaction catalyzed by the enzymes putrescine oxidase and polyamine oxidase with POCL. The same analytes were determined in a later study [46], together with the acetyl derivatives. The sensitive determination of uric acid, selectively converted to hydrogen peroxide by uricase, has been investigated by several authors [37, 47],... [Pg.158]

On the other hand, several oxidases are known to generate hydrogen peroxide, acting as an oxidant in the CL system, from corresponding substrates. IMERs in which the oxidases are immobilized on adequate supporting materials such as glass beads have been developed. IMERs are often used for flow injection with CL detection of uric acid and glucose, and are also applicable to the CL determination of acetylcholine, choline, polyamines, enzyme substrates, etc., after online HPLC separation. [Pg.403]

For the assay of uric acid, a sensor based on KMn04-octylphenyl polyglycol ether is proposed [88], Uric acid can be assayed directly in urine in the 0.10— 600- ag/mL concentration range with a detection limit of 55 ng/mL. The system is free of interferences. [Pg.584]

Figure 3.9 Elution volumes (ml) of alternative void volume markers. Column, 5 im octadecyl-bonded silica gel, 15 cm x 4.5 mm i.d. eluents A and B, 10-90% aqueous acetonitrile, eluents C and D, 10-90% aqueous acetonitrile containing 50 mMphosphoric acid flow rate, 1 ml min temperature, 30 °C detection, UV 210 nm and refractometer. Sample a, acetonitrile b, methanol c, fructose d, 2,4-dinitronaphthol e, sodium nitrate, f, tetrahydrofuran g, deuterium oxide, and h, uric acid. Figure 3.9 Elution volumes (ml) of alternative void volume markers. Column, 5 im octadecyl-bonded silica gel, 15 cm x 4.5 mm i.d. eluents A and B, 10-90% aqueous acetonitrile, eluents C and D, 10-90% aqueous acetonitrile containing 50 mMphosphoric acid flow rate, 1 ml min temperature, 30 °C detection, UV 210 nm and refractometer. Sample a, acetonitrile b, methanol c, fructose d, 2,4-dinitronaphthol e, sodium nitrate, f, tetrahydrofuran g, deuterium oxide, and h, uric acid.
Conditions columns, Asahipak GS320 (vinyl alcohol copolymer gel), 50 cm x 7.6 mm i.d. eluent, 0.1 M sodium phosphate containing 0.3 M sodium chloride pH 7.0 flow rate, 1 ml min-1 detection, UV 250 nm direct injection of sample. Peaks l, protein, 2, orotidine 3, creatinine, and 4, uric acid. [Pg.51]


See other pages where Uric acid detection is mentioned: [Pg.125]    [Pg.283]    [Pg.181]    [Pg.225]    [Pg.1426]    [Pg.125]    [Pg.283]    [Pg.181]    [Pg.225]    [Pg.1426]    [Pg.40]    [Pg.103]    [Pg.64]    [Pg.102]    [Pg.57]    [Pg.59]    [Pg.65]    [Pg.67]    [Pg.69]    [Pg.70]    [Pg.74]    [Pg.172]    [Pg.83]    [Pg.186]    [Pg.520]    [Pg.538]    [Pg.590]    [Pg.592]    [Pg.239]    [Pg.584]    [Pg.159]    [Pg.24]    [Pg.106]    [Pg.209]    [Pg.209]   