Ultraviolet Standards

2-Aminopyridine has been suggested as a standard from 31S to 480 run, which covers most, but not aU, of die wavelengths needed for tryptophan fluorescence (Ikble 1.7 [Pg.639]


Haupt has discussed alkaline chromate solution as an ultraviolet standard and Haupt and Douglas have published transmission values of potassium dichromate solution. [Pg.267]

Atomic Absorption Spectroscopy. Mercury, separated from a measured sample, may be passed as vapor iato a closed system between an ultraviolet lamp and a photocell detector or iato the light path of an atomic absorption spectrometer. Ground-state atoms ia the vapor attenuate the light decreasiag the current output of the photocell ia an amount proportional to the concentration of the mercury. The light absorption can be measured at 253.7 nm and compared to estabUshed caUbrated standards (21). A mercury concentration of 0.1 ppb can be measured by atomic absorption. [Pg.108]

The Reich test is used to estimate sulfur dioxide content of a gas by measuring the volume of gas required to decolorize a standard iodine solution (274). Equipment has been developed commercially for continuous monitoring of stack gas by measuring the near-ultraviolet absorption bands of sulfur dioxide (275—277). The deterrnination of sulfur dioxide in food is conducted by distilling the sulfur dioxide from the acidulated sample into a solution of hydrogen peroxide, foUowed by acidimetric titration of the sulfuric acid thus produced (278). Analytical methods for sulfur dioxide have been reviewed (279). [Pg.147]

Physical Chemical Characterization. Thiamine, its derivatives, and its degradation products have been fully characterized by spectroscopic methods (9,10). The ultraviolet spectmm of thiamine shows pH-dependent maxima (11). H, and nuclear magnetic resonance spectra show protonation occurs at the 1-nitrogen, and not the 4-amino position (12—14). The H spectmm in D2O shows no resonance for the thiazole 2-hydrogen, as this is acidic and readily exchanged via formation of the thiazole yUd (13) an important intermediate in the biochemical functions of thiamine. Recent work has revised the piC values for the two ionization reactions to 4.8 and 18 respectively (9,10,15). The mass spectmm of thiamine hydrochloride shows no molecular ion under standard electron impact ionization conditions, but fast atom bombardment and chemical ionization allow observation of both an intense peak for the patent cation and its major fragmentation ion, the pyrimidinylmethyl cation (16). [Pg.85]

Oxidants commonly used include ozone, permanganate, chlorine, chlorine dioxide, and ferrate, often in combination with catalysts. Standard-type mixed reactors are used with contact times of several minutes to an hour. Special reactors for use with ultraviolet light have been developed. [Pg.2227]

In Laser Ionization Mass Spectrometry (LIMS, also LAMMA, LAMMS, and LIMA), a vacuum-compatible solid sample is irradiated with short pulses ("10 ns) of ultraviolet laser light. The laser pulse vaporizes a microvolume of material, and a fraction of the vaporized species are ionized and accelerated into a time-of-flight mass spectrometer which measures the signal intensity of the mass-separated ions. The instrument acquires a complete mass spectrum, typically covering the range 0— 250 atomic mass units (amu), with each laser pulse. A survey analysis of the material is performed in this way. The relative intensities of the signals can be converted to concentrations with the use of appropriate standards, and quantitative or semi-quantitative analyses are possible with the use of such standards. [Pg.44]

In Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), a gaseous, solid (as fine particles), or liquid (as an aerosol) sample is directed into the center of a gaseous plasma. The sample is vaporized, atomized, and partially ionized in the plasma. Atoms and ions are excited and emit light at characteristic wavelengths in the ultraviolet or visible region of the spectrum. The emission line intensities are proportional to the concentration of each element in the sample. A grating spectrometer is used for either simultaneous or sequential multielement analysis. The concentration of each element is determined from measured intensities via calibration with standards. [Pg.48]

Select the detector. To acquire molecular weight distribution data, use a general detector such as a refractive index detector. To acquire structural or compositional information, employ a more selective detector such as an ultraviolet (UV) or infrared (IR) detector. Viscometric and light-scattering detectors facilitate more accurate molecular weight measurement when appropriate standards are not available. [Pg.78]

Most frequently, SEC with dextran-, pullulan-, or polystyrene calibration standards has been used to characterize the molecular properties of xylans. However, as for viscometric studies [108], a sufficient solvent ionic strength is a prerequisite for useful SEC measurements of charged polysaccharides, including glucuronoxylans [111-113]. An advantage of the SEC technique is that the presence of protein and phenolic components or oxidative changes can be detected by simultaneous ultraviolet (UV) detection. [Pg.16]

The derivatization process (5) is accomplished in aqueous media at basic pH (pH 7-10) in a matter of approximately 15 min to yield a 2-cyanobenz[f]isoindole (CBI), which is stable for 10 to 12 hr in solution. As shown in Figure 1, the absorption characteristics of the CBI adducts are also readily accessible for assay by standard fluorescence or ultraviolet detection. In addition to the absorption between 200 and 300 nm, there are two maxima in the visible spectrum at approximately 420 and 440 nm accessible for fluorescence or ultraviolet detection. A probable mechanism (5,11) for the CBI formation is illustrated in Scheme 1. [Pg.129]


See other pages where Ultraviolet Standards is mentioned: [Pg.639]    [Pg.639]    [Pg.872]    [Pg.1122]    [Pg.1122]    [Pg.388]    [Pg.122]    [Pg.470]    [Pg.290]    [Pg.212]    [Pg.410]    [Pg.552]    [Pg.414]    [Pg.101]    [Pg.128]    [Pg.36]    [Pg.531]    [Pg.890]    [Pg.462]    [Pg.210]    [Pg.142]    [Pg.677]    [Pg.655]    [Pg.98]    [Pg.256]    [Pg.126]    [Pg.37]    [Pg.153]    [Pg.112]    [Pg.123]    [Pg.220]    [Pg.221]    [Pg.164]    [Pg.5]    [Pg.380]    [Pg.2]    [Pg.341]    [Pg.421]    [Pg.136]   