In early Me UPD studies on single crystal substrates S [3.89, 3.98, 3.122], classical electrochemical techniques such as cyclic voltammetry, r(E,ju) isotherm measurements using thin-layer techniques ( PlL, FTTL), transient techniques in the time domain, and electrochemical impedance spectroscopy (EIS) in the frequency... [Pg.71]

In time domain measurements, the electrochemical system is subjected to a potential variation that is the resultant of many frequencies, like a pulse or white noise signal, and the time-dependent current from the cell is recorded. The stimulus and the response can be converted via Fourier transform methods to spectral representations of amplitude and phase angle frequency, from which the desired impedance can be computed as a function of frequency. [Pg.407]

Metelko D, Jamnik J, Pejovnik S (1992) Comparison between the impedance spectra of Li/SOCl2 batteries obtained using the time and the frequency domain measurement techniques. J Appl Electrochem 22 638 13... [Pg.262]

Remember 21.1 The stochastic errors in impedance measurements arise from an integration of time-domain signals that contain noise originating from the electrochemical cell and the instrumentation. [Pg.409]

Conventional kinetics is largely concerned with the description of dynamic processes in the time domain, and in consequence few conceptual problems are encountered in understanding time resolved experiments. By contrast, frequency resolved measurements often pose more of a challenge to understanding, in spite of the obvious correspondence between the time and frequency domains. This conceptual difficulty may explain why the only frequency resolved method to achieve universal acceptance in electrochemistry is electrochemical impedance spectroscopy (EIS) [27-29], which analyses the response of electrochemical systems to periodic (sinusoidal) perturbations of voltage or current. It is clear that EIS is a very powerful method, and there... [Pg.80]

ABSTRACT State determination of Li-ion cells is often accomplished with Electrochemical Impedance Spectroscopy (EIS). The measurement results are in frequency domain and used to describe the state of a Li-ion cell by parameterizing impedance-based models. Since EIS is a costly measurement method, an alternative method for the parameterization of impedance-based models with time-domain data easier to record is presented in this work. For this purpose the model equations from the impedance-based models are transformed from frequency domain into time domain. As an excitation signal a current step is applied. The resulting voltage step responses are the model equations in time domain. They are presented for lumped and derived for distributed electrical circuit elements, i.e. Warburg impedance, Constant Phase Element and RCPE. A resulting technique is the determination of the inner resistance from an impedance spectrum which is performed on measurement data. [Pg.3]

In most cases, the measurements are carried out isothermally in the frequency domain and the terms dielectric spectroscopy (DS) and dielectric relaxation spectroscopy (DRS) are then used. Other terms frequently used for DRS are impedance spectroscopy and admittance spectroscopy. Impedance spectroscopy is usually used in connection with electrolytes and electrochemical studies, whereas admittance spectroscopy often refers to semiconductors and devices. Isothermal measurements in the time domain are often used, either as a convenient tool for extending the range of measurements to low frequencies (slow time-domain spectroscopy, dc transient current method, isothermal charging-discharging current measurements) or for fast measurements corresponding to the frequency range of about 10 MHz - 10 GHz (time-domain spectroscopy or time-domain reflectometry). Finally, TSDC is a special dielectric technique in the temperature domain, which will be discussed in Section 2.2. [Pg.383]


See other pages where Time domain measurements, electrochemical is mentioned: [Pg.349]    [Pg.198]    [Pg.85]    [Pg.282]    [Pg.451]    [Pg.256]    [Pg.332]    [Pg.87]    [Pg.126]    [Pg.104]    [Pg.522]    [Pg.187]    [Pg.182]    [Pg.1466]    [Pg.345]    [Pg.4968]    [Pg.429]    [Pg.1197]    [Pg.172]    [Pg.440]    [Pg.104]    [Pg.441]    [Pg.24]    [Pg.156]    [Pg.171]    [Pg.318]    [Pg.25]    [Pg.103]    [Pg.282]    [Pg.451]    [Pg.120]    [Pg.51]    [Pg.153]    [Pg.24]    [Pg.61]    [Pg.155]    [Pg.194]    [Pg.184]    [Pg.214]    [Pg.12]    [Pg.249]    [Pg.326]    [Pg.214]   


SEARCH



Electrochemical domain

Electrochemical measurements

Measuring time

Time domain

Time domain measurements