Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

System interrupts

An interrupt is a procedure by which the normal sequence of software instructions within the computer is suspended whilst another operation or routine is carried out. When the latter has been completed the suspended software sequence is resumed. Interrupts are normally provided in terms of  [Pg.696]

The operator forms an essential link in any total plant instrumentation and control strategy, and the conveying of information to the process plant operator and the speed at which the operator is able to respond are important considerations. Methods of presentation of information (concerning plant status) to the plant operator, manager or engineer are undergoing a considerable evolution and the effectiveness of the presentation of process data is dependent upon the hardware employed to visualise the data and the protocol used to display it. [Pg.696]

Many different methods of information display (of varying degrees of sophistication) can be found on process plants. These can be divided into  [Pg.696]

Often there will be combinations of these and plants will have some means of visually recording data (e.g. by the use of charts) as well as employing indicators to show immediate readings. Retrofitted (updated) units may contain all four methods of presentation. Newer plant is more likely to employ the video terminal as the principal source of information, although local indicators may well be fixed to pumps, etc. [Pg.697]

The way in which information is presented on the video display to the operator is of considerable significance. Bailey(34) recommends that  [Pg.697]


User back-up/altemative procedures Procedure describing steps to be taken for the continued recording and control of the raw data in the event of a computer system interruption or failure. [Pg.185]

D. Enhanced elimination. Repeat-dose activated charcoal may enhance fecal elimination by binding thallium secreted into the gut lumen or via the biliary system, interrupting enterohepatic or enteroenteric recirculation. Forced diuresis, dialysis, and hemoperfusion are of no proven benefit. [Pg.354]

At the sharp end, decisions, actions, and inaction contributing to accidents are called active failures, a term that connotes the immediacy of adverse effects (Reason, 1997). Active failures are direct operational errors (Reason, 1997 Weick, 2000). Weick has identified four processes, familiar ways of doing things, that can emerge under stress and become sources of vulnerability for sharp-end providers in complex systems interruption of important routines, regression during a crisis. [Pg.47]

Among the additives which may be used as substitutes for these systems, intumescent additives seems to be particularly attractive. Fire protection of flammable materials (in particular, paints, varnishes and cellulose-based materials) by an intumescence process has been known for several years [1]. Intumescent technology has more recently found a place in polymer science as a method of providing flame retardancy to polymer formulations, especially polypropylene (PP) formulations [2]. These systems interrupt the self-sustained combustion of the polymer at its earliest stage, i.e. the thermal degradation with evolution of the gaseous fuels. [Pg.357]

Fig. 24. Comparison of equilibrium of the decomposition of methanol by steam in dependence on pressure, for the ideal system (interrupted lines) and in the real gas state (full curves) at 900 K. (Order of constituents 1 — CH4, 2 — H2O, 3 — H2, 4 — CO, 5 — CO2)... Fig. 24. Comparison of equilibrium of the decomposition of methanol by steam in dependence on pressure, for the ideal system (interrupted lines) and in the real gas state (full curves) at 900 K. (Order of constituents 1 — CH4, 2 — H2O, 3 — H2, 4 — CO, 5 — CO2)...
In any case, I eventually recovered (and so did Jerry), but my immune system must have suffered serious damage, which manifested itself three years later, when I collapsed in my office one day and was found to be bleeding internally from a form of rare stomach cancer, which necessitated major surgery but was fortunately localized. I again recovered and have had no further difficulties since. Whether weakening and knocking out my immune system to overcome the previous problems had any effect is not clear, but it could have been a factor. Despite my health problems I was able to continue my work without much interruption, and the scientific productivity of my group has not... [Pg.117]

The Birch reductions of C C double bonds with alkali metals in liquid ammonia or amines obey other rules than do the catalytic hydrogenations (D. Caine, 1976). In these reactions regio- and stereoselectivities are mainly determined by the stabilities of the intermediate carbanions. If one reduces, for example, the a, -unsaturated decalone below with lithium, a dianion is formed, whereof three different conformations (A), (B), and (C) are conceivable. Conformation (A) is the most stable, because repulsion disfavors the cis-decalin system (B) and in (C) the conjugation of the dianion is interrupted. Thus, protonation yields the trans-decalone system (G. Stork, 1964B). [Pg.103]

Solvent-divert system. Used in conjunction with an interface, it permits temporary interruption of the flow from a chromatograph to a mass spectrometer by briefly opening a valve to a pumping line. Thus effluent present at a high concentration (usually solvent) does not enter the mass spectrometer ion source. [Pg.433]

Real-time clocks (RTCs). Real-time systems are required to respond to events, as they occur, in a timely manner. This is especially crucial in process control systems where control actions applied at the wrong time may amplify process deviations or destabilize the processes. The nodes in the systems are interrupted periodically by the real-time clocks to maintain the ac tual elapsed times. [Pg.772]

Actuators often provide a failsafe function. In the event of an interruption in the powder source, the actuator will place the valve in a predetermined safe position, iisiiallv either full open or full closed. Safety systems are often designed to trigger local failsafe action at specific valves to cause a needed action to occur, vv4uch rnav not be a complete process or plant shutdown. [Pg.780]

Adsorption-Control Equipment If a gas stream must be treated for a short period, nsnally only one adsorption unit is necessary, provided, of course, that a sufficient time interval is available between adsorption cycles to permit regeneration. However, this is usually not the case. Since an nninternipted flow of treated gas is often required, it is necessary to employ one or more units capable of operating in this fashion. The units are designed to handle gas flows without interruption and are charac terized by their mode of contact, either staged or continuous. By far the most common type of adsorption system used to remove an objectionable pollutant from a gas stream consists of a number of fixed-bed units operating in such a sequence that the gas flow remains nninternipted. A two- or three-bed system is nsn ly... [Pg.2187]

Low power usage Very long life No Oil required Low system weight Reduced fire hazard Vibration sensors built-in Small load capacity Large size Higher investment Requires mechanical backup for power interruptions New technology Possible rotor-d3ntiamic problems... [Pg.2535]

Eail-Safe Design features which provide for the maintenance of safe operating conditions in the event of a malfunction of control devices or an interruption of an energy source (e.g., direction of failure of a control valve on loss of signal). A system is fail-safe if failure of a component, signal, or utility that would create a hazard initiates an action that maintains the system in a safe condition. [Pg.161]

With the availability of 3.3 and 6.6 kV vacuum contactors the control of HT motors up to 6.6 kV systems has now become easier and economical, compact and even more reliable. For 11 kV. systems, vacuum as well as SF (Sulphur hexafluoride) breakers can be used. The HT motor s switching and protection through a vacuum contactor provides a replica of an LT system. The earlier practice of using an HT OCB, MOCB, or an air blast circuit breaker for the interruption of an HT circuit is now a concept of the past. [Pg.308]


See other pages where System interrupts is mentioned: [Pg.901]    [Pg.83]    [Pg.278]    [Pg.696]    [Pg.130]    [Pg.176]    [Pg.816]    [Pg.198]    [Pg.176]    [Pg.404]    [Pg.144]    [Pg.987]    [Pg.80]    [Pg.487]    [Pg.612]    [Pg.133]    [Pg.21]    [Pg.780]    [Pg.528]    [Pg.901]    [Pg.83]    [Pg.278]    [Pg.696]    [Pg.130]    [Pg.176]    [Pg.816]    [Pg.198]    [Pg.176]    [Pg.404]    [Pg.144]    [Pg.987]    [Pg.80]    [Pg.487]    [Pg.612]    [Pg.133]    [Pg.21]    [Pg.780]    [Pg.528]    [Pg.162]    [Pg.343]    [Pg.344]    [Pg.223]    [Pg.298]    [Pg.1337]    [Pg.1548]    [Pg.1555]    [Pg.1557]    [Pg.2139]    [Pg.2440]    [Pg.42]    [Pg.76]    [Pg.132]    [Pg.133]    [Pg.261]    [Pg.290]   


SEARCH



Interruptions

Interrupts, alarm system

© 2024 chempedia.info