Sump pumps availability

Sump pumps can draw water up from levels as much as 30 ft below the pump s suction. But do such pumps require NPSH Absolutely All centrifugal pumps have some NPSH requirements. What, then, is the available NPSH to the sump pump shown in Fig. 25.8 ... [Pg.338]

This 11.5 ft is the NPSH available to the pump. The pump itself requires only 6 ft of NPSH to pump 1200 GPM of water. Hence, even though the pump s suction is 9 ft above the water in the sump, the available NPSH is twice the required NPSH. [Pg.338]

Where, then, does the available NPSH to a sump pump really come from It comes from atmospheric pressure. Atmospheric pressure, at sea level, is equivalent to... [Pg.338]

A computer is programmed to calculate leakage rates utilizing the frequency and interval of time the sump pumps operate in combination with the known pumping rate of the pumps. Digital readouts are available to the operator. [Pg.76]

A form of hard Neoprene is available for upper and lower screens of vertical sump pumps and for cap nuts and flingers that protect the shaft seals. Its nominal hardness is 80 Shore A, but it can be postcured to a hardness of 85 Shore A. [Pg.524]

A hydraulic system must have a reserve of fluid in addition to that contained in the pumps, actuators, pipes and other components of the system. This reserve fluid must be readily available to make up losses of fluid from the system, to make up for compression of fluid under pressure, and to compensate for the loss of volume as the fluid cools. This extra fluid is contained in a tank usually called a reservoir. A reservoir may sometimes be referred to as a sump tank, service tank, operating tank, supply tank or base tank. [Pg.605]

Flashing occurs when the liquid vapor pressure exceeds the static pressure in the outlet pipe. To avoid flashing, sufficient liquid head should be available at the sump, and the outlet pipes should be correctly sized. Sizing should take into account reasonable variations in outlet flow. Pump suction lines should be as short as possible and run without loops or pockets. One troublesome experience with flashing at the entrance to a side-draw line has been reported (85). [Pg.90]

After the diking arrangement has been e.stabli.shed. there are a few additional factors to plan for. The grade sloping awa from the tanks to a. sump must be determined minor. spills and rainwater may have to be pumped from the. sump to a treating pond. Dike heights mast also be established on the basis of inventories and available real estate. [Pg.368]

An adequate drainage system should be provided for all locations where a large amount of liquid has the possibility of release and may accumulate according to the terms of the risk analysis frequency levels. Normal practice is to ensure adequate drainage capability exists at all pumps, tanks, vessels, columns, etc., supplemented by area surface runoff or general area catch basins. Sewer systems are normally gravity flow for either sanitary requirements or oily water surface disposal. Where insufficient elevation is available for the main header, sump collection pits are provided, fitted with... [Pg.171]


See other pages where Sump pumps availability is mentioned: [Pg.337]    [Pg.346]    [Pg.62]    [Pg.284]    [Pg.362]    [Pg.408]    [Pg.252]    [Pg.1060]    [Pg.362]    [Pg.85]    [Pg.227]    [Pg.41]    [Pg.362]    [Pg.301]    [Pg.100]    [Pg.1197]    [Pg.454]    [Pg.463]    [Pg.121]    [Pg.419]    [Pg.296]   