Styragel column calibration curve

Tables 11.1 through 11.4 give useful ranges for the various Styragel and Ultrahydrogel packings. It should be pointed out that Styragel packings with the designation E at the end of the name are mixed-bed columns with an extended range of the calibration curve. To view the full range of each calibration curve, go to the sections that discuss the individual column types. Tables 11.1 through 11.4 give useful ranges for the various Styragel and Ultrahydrogel packings. It should be pointed out that Styragel packings with the designation E at the end of the name are mixed-bed columns with an extended range of the calibration curve. To view the full range of each calibration curve, go to the sections that discuss the individual column types.
FIGURE I 1.6 Calibration curves of Waters Styragel HR columns. (Courtesy of Waters Corp.)... [Pg.337]

Molecular weights were determined using a Waters high-pressure GPC instrument (Model 6000 A pymp, a series of five p-Styragel columns (10s, 10s, 10, 103, 500 A), Differential Refractometer 2401 and UV Absorbance Detector Model (440) and a calibration curve made by well fractionated polyisobutylene standards. [Pg.127]

Figure 1. Calibration curve for four -styragel columns CPS in TCB at 135 °C). Figure 1. Calibration curve for four -styragel columns CPS in TCB at 135 °C).
The molecular mass characteristics of PP and copolymers were determined at 135°C in o-dichlorobenzene on a Waters 150-C gel chromatograph equipped with a linear HT-p-styragel column. The average molecular mass was calculated from the universal calibration curve plotted relative to PS standards. [Pg.180]

The Styragel 1000 column (1.0 x 42 cm) was prepared from resin swollen with benzene-methanol (90 10 v/v). Polystyrene standards were used for molecular weight calibration, and an exclusion limit of 28,000 was determined. The Sephadex-excluded asphaltene fraction was chromatographed on the Styragel 1000 column and a continuous elution curve was obtained from molecular weight 22,000 to 1000. [Pg.35]


See other pages where Styragel column calibration curve is mentioned: [Pg.328]    [Pg.335]    [Pg.337]    [Pg.339]    [Pg.5]    [Pg.93]    [Pg.149]    [Pg.102]    [Pg.104]    [Pg.1222]    [Pg.262]    [Pg.1598]    [Pg.262]    [Pg.117]    [Pg.316]    [Pg.122]    [Pg.386]    [Pg.1150]    [Pg.133]    [Pg.546]    [Pg.171]    [Pg.104]    [Pg.110]    [Pg.91]    [Pg.132]   