Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Current standing

In contrast to the other ionization detectors a decrease in the detector background current is measured rather than an increase in the number of ions or electrons generated. The detector standing current results from the bombardment of the carrier gas by beta electrons forming a plasma of positive ions. [Pg.141]

Edelman, R. 2002. The development and use of vaccine adjuvants. Molecular Biotechnology 21(2), 129-148. Francis, J. and Larche, M. 2005. Peptide-based vaccination where do we stand Current Opinion in Allergy and Clinical Immunology 5(6), 537-543. [Pg.418]

These entities would then cause a reduction in the standing or background current. This phenomenon is known as electron capture and is observed more readily at lower electrode potentials. Essentially a current of electrons is monitored so that when an electroactive solute passes through this stream there is a decrease in the standing current. [Pg.256]

The helium ionization detector (HID) is a sensitive universal detector. In the detector, Ti3H2 or Sc3H3 is used as an ionization source of helium. Helium is ionized to the metastable state and possesses an ionization potential of 19.8 eV. As metastable helium has a higher ionization potential than most species except for neon, it will be able to transfer its excitation energy to all other atoms. As other species enter the ionization field the metastable helium will transfer its excitation energy to other species of lower ionization potential, and an increase in ionization will be measured over the standing current. [Pg.311]

High purity nitrogen gas is used for direct current electron capture detectors. This gas should be filtered and dry. An exhausted drier will allow passage of water and reduce the standing current. [Pg.203]

Samples were routinely analyzed on a 5 x %" SS column packed with 5% SE-30 silicone gum on 60-80 mesh Chromosorb W. A second column 7 x 3/16" SS packed with 5% SE-30 silicone gum on 80-90 mesh Anakrom ABS, was used to verify the presence of isopropyl 2,4-D. Water-pumped nitrogen carrier gas was filtered through a 13X molecular sieve at a flow rate of 25 ml./min. The injection block temperature was 250°C., and column oven temperatures between 190° and 205°C. gave optimum peak separation for the columns used. The detector was removed and cleaned whenever the standing current dropped below 200 with a detector voltage of 60 volts. [Pg.228]

The detector can be made to function in two ways either a constant potential is applied across the sensor electrodes (the DC mode) or a pulsed potential is used (the pulsed mode). In the DC mode, a constant electrode potential of a few volts is employed that is just sufficient to collect all the electrons that are produced and provide a small standing current. If an electron capturing molecule (for example a molecule containing a halogen atom which has only seven electrons in its outer shell) enters the sensor, the electrons are captured by the molecules and the molecules become charged. The mobility of the captured electrons are much reduced compared with the free electrons and, furthermore, are more likely to be neutralized by collision with any positive ions that are also generated. As a consequence, the electrode current falls dramatically. [Pg.137]

The electrons produced by the radioactive source were accelerated under a potential that ranged from 800 to 2000 V, depending on the size of the sensor and the position of the electrodes. The signal is taken across a 1 xl 0 -0 resistor, and as the standing current from the ionization of the argon is about 2 x 10 A,... [Pg.190]

The values of h and — Ie (the peak height) were measured with a ruler and the temperature read from a thermometer next to the detector in a metal heating block. The column and injector temperatures were kept constant. The response was corrected for the small change in the standing current by multiplying by Imax/h = 21.2/7/,. The volumetric flow rate was corrected by multiplying by 77300 K. [Pg.79]

The ceU is normally polarized with an applied potential, and electrons (fi rays) emitted from the source at the cathode strike gas molecules, causing electrons to be released. The resulting cascade of thermal electrons is attracted to the anode, and establishes a standing current. When a compound possessing electron... [Pg.586]

The amount of discodermolide produced would equate to around 3000 kg of sponge, a quantity that probably does not exist The total number of steps is 36 with an overall yield of 0.2% (main chain). This is on the low side, but it should be remembered that the yields for each step have not been optimized. The description of the various optimization processes in this article have only related to the various scale-up and reproducibility issues, not to obtaining the maximum possible yield, so there is plenty of scope for increasing the yield. There were, in this second campaign, some 18 chromatographic purifications. This has now been somewhat reduced to 14. The number of crystalline intermediates stands currently at 7. [Pg.314]

The last few years have witnessed a high level of activity pertaining to the research and development of all-solid, thin-film polymer electrolyte batteries most of these use lithium as the active anode material, polymer-based matrices as solid electrolytes, and insertion compounds as active cathode materials. High-performance prototypes of such batteries stand currently under research, whose trends are expected to include the development of amorphous polymers with very low glass-transition temperatures, mixed polymer electrolytes, and fast-ion conductors in which the cationic transport number approaches unity. [Pg.225]


See other pages where Current standing is mentioned: [Pg.143]    [Pg.656]    [Pg.440]    [Pg.4]    [Pg.259]    [Pg.264]    [Pg.102]    [Pg.453]    [Pg.74]    [Pg.51]    [Pg.220]    [Pg.138]    [Pg.94]    [Pg.259]    [Pg.122]    [Pg.139]    [Pg.350]    [Pg.606]    [Pg.607]    [Pg.730]    [Pg.154]    [Pg.116]    [Pg.77]    [Pg.80]    [Pg.83]    [Pg.147]    [Pg.148]    [Pg.634]    [Pg.634]    [Pg.720]    [Pg.235]    [Pg.235]    [Pg.237]    [Pg.795]    [Pg.699]   
See also in sourсe #XX -- [ Pg.256 ]




SEARCH



Stands

© 2024 chempedia.info