Electronic transitions spectroscopy

SHG spectroscopy SFG spectroscopy Electronic transitions. Vibrational transitions identification of interfacial molecules. Quantitative analysis complicated knowledge of hyperpolarizabilities of each vibrational mode required. [Pg.339]

Although several important classes of boron compounds will not be discussed here because of space limitation, this chapter attempts to discuss the representative transformations which are likely to be useful for researchers with little experience in organoboron chemistry. No attempt is made to cover in detail physical properties however, information on boron-carbon bond lengths, nuclear magnetic resonance ( B and H), vibrational spectroscopy, electronic transitions, mass spectrometry, and thermodynamic properties of organoboron compounds has been summarized in earlier texts [1]. [Pg.345]

In absorption spectroscopy, the attenuation of light as it passes tln-ough a sample is measured as a function of wavelength. The attenuation is due to rovibrational or electronic transitions occurring in the sample. Mapping out the attenuation versus photon frequency gives a description of the molecule or molecules responsible for the absorption. The attenuation at a particular frequency follows the Beer-Lambert law,... [Pg.805]

The SHG/SFG technique is not restricted to interface spectroscopy of the delocalized electronic states of solids. It is also a powerful tool for spectroscopy of electronic transitions in molecules. Figure Bl.5.13 presents such an example for a monolayer of the R-enantiomer of the molecule 2,2 -dihydroxyl-l,l -binaphthyl, (R)-BN, at the air/water interface [ ]. The spectra reveal two-photon resonance features near wavelengths of 332 and 340 mu that are assigned to the two lowest exciton-split transitions in the naphtli-2-ol... [Pg.1293]

Heinz T F, Himpsel F J, Palange E and Burstein E 1989 Electronic transitions at the CaF2/Si(111) interface probed by resonant three-wave-mixing spectroscopy Phys. Rev. Lett. 63 644-7... [Pg.1303]

Electron-impact energy-loss spectroscopy (EELS) differs from other electron spectroscopies in that it is possible to observe transitions to states below the first ionization edge electronic transitions to excited states of the neutral, vibrational and even rotational transitions can be observed. This is a consequence of the detected electrons not originating in the sample. Conversely, there is a problem when electron impact induces an ionizing transition. For each such event there are two outgoing electrons. To precisely account for the energy deposited in the target, the two electrons must be measured in coincidence. [Pg.1307]

Pump-probe absorption experiments on the femtosecond time scale generally fall into two effective types, depending on the duration and spectral width of the pump pulse. If tlie pump spectrum is significantly narrower in width than the electronic absorption line shape, transient hole-burning spectroscopy [101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112 and 113] can be perfomied. The second type of experiment, dynamic absorption spectroscopy [57, 114. 115. 116. 117. 118. 119. 120. 121 and 122], can be perfomied if the pump and probe pulses are short compared to tlie period of the vibrational modes that are coupled to the electronic transition. [Pg.1979]

Concelcao J, Laaksonen R T, Wang L S, Guo T, Nordlander P and Smalley R E 1995 Photoelectron spectroscopy of transition metal clusters correlation of valence electronic structure to reactivity Rhys. Rev. B 51 4668... [Pg.2403]

The structural unit associated with an electronic transition m UV VIS spectroscopy IS called a chromophore Chemists often refer to model compounds to help interpret UV VIS spectra An appropriate model is a simple compound of known structure that mcor porates the chromophore suspected of being present m the sample Because remote sub stituents do not affect Xmax of the chromophore a strong similarity between the spectrum of the model compound and that of the unknown can serve to identify the kind of rr electron system present m the sample There is a substantial body of data concerning the UV VIS spectra of a great many chromophores as well as empirical correlations of sub stituent effects on k Such data are helpful when using UV VIS spectroscopy as a tool for structure determination... [Pg.567]

Vibrational transitions accompanying an electronic transition are referred to as vibronic transitions. These vibronic transitions, with their accompanying rotational or, strictly, rovibronic transitions, give rise to bands in the spectrum, and the set of bands associated with a single electronic transition is called an electronic band system. This terminology is usually adhered to in high-resolution electronic spectroscopy but, in low-resolution work, particularly in the liquid phase, vibrational structure may not be resolved and the whole band system is often referred to as an electronic band. [Pg.242]

In electronic spectroscopy of polyatomic molecules the system used for labelling vibronic transitions employs N, to indicate a transition in which vibration N is excited with v" quanta in the lower state and v quanta in the upper state. The pure electronic transition is labelled Og. The system is very similar to the rather less often used system for pure vibrational transitions described in Section 6.2.3.1. [Pg.279]

Shorter-wavelength radiation promotes transitions between electronic orbitals in atoms and molecules. Valence electrons are excited in the near-uv or visible. At higher energies, in the vacuum uv (vuv), inner-shell transitions begin to occur. Both regions are important to laboratory spectroscopy, but strong absorption by make the vuv unsuitable for atmospheric monitoring. Electronic transitions in molecules are accompanied by stmcture... [Pg.311]

Spectroscopy in the uv—vis detects electronic transitions, and so is appHcable to both atoms and molecules. This is a mature technique having important quahtative and quantitative appHcations (137—141). [Pg.316]

RAIRS spectra contain absorption band structures related to electronic transitions and vibrations of the bulk, the surface, or adsorbed molecules. In reflectance spectroscopy the ahsorhance is usually determined hy calculating -log(Rs/Ro), where Rs represents the reflectance from the adsorhate-covered substrate and Rq is the reflectance from the bare substrate. For thin films with strong dipole oscillators, the Berre-man effect, which can lead to an additional feature in the reflectance spectrum, must also be considered (Sect. 4.9 Ellipsometry). The frequencies, intensities, full widths at half maximum, and band line-shapes in the absorption spectrum yield information about adsorption states, chemical environment, ordering effects, and vibrational coupling. [Pg.251]

The preceding empirical measures have taken chemical reactions as model processes. Now we consider a different class of model process, namely, a transition from one energy level to another within a molecule. The various forms of spectroscopy allow us to observe these transitions thus, electronic transitions give rise to ultraviolet—visible absorption spectra and fluorescence spectra. Because of solute-solvent interactions, the electronic energy levels of a solute are influenced by the solvent in which it is dissolved therefore, the absorption and fluorescence spectra contain information about the solute-solvent interactions. A change in electronic absorption spectrum caused by a change in the solvent is called solvatochromism. [Pg.435]

Frequently, electrochemical information can be interpreted better in the presence of additional nonelectrochemical information. Typically, however, there is one significant restriction electrochemical and spectroscopic techniques often do not detect exactly the same mechanisms. With spectroscopic measurements (e.g., infrared spectroscopy), products that are formed by electrochemical processes may be detected. In other cases (luminescence techniques) mechanisms may be found by which charge carriers are trapped and recombine. Other techniques (electroreflection studies) allow the nature of electronic transitions to be determined and provide information on the presence or absence of an electric field in the surface of an electrode. With no traditional technique, however, is it... [Pg.435]

Gutierrez, C. Potential-Modulated Reflectance Spectroscopy Studies of the Electronic Transitions of Chemisorbed Carbon Monoxide 28... [Pg.604]


See other pages where Electronic transitions spectroscopy is mentioned: [Pg.371]    [Pg.162]    [Pg.133]    [Pg.80]    [Pg.371]    [Pg.162]    [Pg.133]    [Pg.80]    [Pg.253]    [Pg.307]    [Pg.1119]    [Pg.1121]    [Pg.1130]    [Pg.1151]    [Pg.1179]    [Pg.1200]    [Pg.1200]    [Pg.1201]    [Pg.1294]    [Pg.2962]    [Pg.2985]    [Pg.410]    [Pg.41]    [Pg.43]    [Pg.208]    [Pg.316]    [Pg.318]    [Pg.41]    [Pg.27]    [Pg.150]    [Pg.385]    [Pg.255]    [Pg.667]    [Pg.67]    [Pg.404]   