Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solids concentration sampling methods

Nuclear reaction analysis (NRA) is used to determine the concentration and depth distribution of light elements in the near sur ce (the first few lm) of solids. Because this method relies on nuclear reactions, it is insensitive to solid state matrix effects. Hence, it is easily made quantitative without reference to standard samples. NRA is isotope specific, making it ideal for isotopic tracer experiments. This characteristic also makes NRA less vulnerable than some other methods to interference effects that may overwhelm signals from low abundance elements. In addition, measurements are rapid and nondestructive. [Pg.680]

Different analytical procedures have been developed for direct atomic spectrometry of solids applicable to inorganic and organic materials in the form of powders, granulate, fibres, foils or sheets. For sample introduction without prior dissolution, a sample can also be suspended in a suitable solvent. Slurry techniques have not been used in relation to polymer/additive analysis. The required amount of sample taken for analysis typically ranges from 0.1 to 10 mg for analyte concentrations in the ppm and ppb range. In direct solid sampling method development, the mass of sample to be used is determined by the sensitivity of the available analytical lines. Physical methods are direct and relative instrumental methods, subjected to matrix-dependent physical and nonspectral interferences. Standard reference samples may be used to compensate for systematic errors. The minimum difficulties cause INAA, SNMS, XRF (for thin samples), TXRF and PIXE. [Pg.626]

The study concluded that Once wash steps are optimized, samples prepared by solid phase extraction are cleaner than those prepared by protein precipitation. Samples prepared by extraction with a Multi-SPE plate resulted in lower LOQs than samples prepared by solvent precipitation. Drug recoveries were acceptable (>80%) for both the SPE and the solvent precipitation methods. Well-to-well reproducibility of samples was slightly better with extraction with a Multi-SPE plate. Evaporation and reconstitution, while more time-consuming, yield better chromatographic performance, allow analysis of lower concentration samples, and require optimization for good analyte recovery. [Pg.53]

The biological applications of NMR include the study of the structure of macromolecules such as proteins and nucleic acids and the study of membranes, and enzymic reactions. Newer methods and instruments have overcome, to a large extent, the technical difficulties encountered with aqueous samples and the analysis of body fluids is possible, permitting the determination of both the content and concentration of many metabolites in urine and plasma. NMR is not a very sensitive technique and it is often necessary to concentrate the sample either by freeze drying and dissolving in a smaller volume cm- by solid phase extraction methods. [Pg.89]

The difference between IGC and conventional analytical gas-solid chromatography is the adsorption of a known adsorptive mobile phase (vapour) on an unknown adsorbent stationary phase (solid state sample). Depending on experiment setup, IGC can be used at finite or infinite dilution concentrations of the adsorptive mobile phase. The latter method is excellent for the determination of surface energetics and heat of sorption of particulate materials [3]. With IGC at finite dilution, it is possible to measure sorption isotherms for the determination of surface area and porosity [4], The benefits of using dynamic techniques are faster equilibrium times at ambient temperatures. [Pg.633]

Figure Gl.7.lisa comparison of chromatograms from a solid-phase microextraction (SPME) from a beverage in a sealed container and from the same beverage in a mouth simulator. This comparison demonstrates that a very different volatile ratio is produced from the same food under different sampling conditions. Due to these differences, it is important to use a sampling method that simulates mouth conditions when studying flavor compositions that produce a human perception. Most methods intended to increase headspace volatile concentration, such as adding salt for salting out, do not uniformly affect volatility. For some compounds,... Figure Gl.7.lisa comparison of chromatograms from a solid-phase microextraction (SPME) from a beverage in a sealed container and from the same beverage in a mouth simulator. This comparison demonstrates that a very different volatile ratio is produced from the same food under different sampling conditions. Due to these differences, it is important to use a sampling method that simulates mouth conditions when studying flavor compositions that produce a human perception. Most methods intended to increase headspace volatile concentration, such as adding salt for salting out, do not uniformly affect volatility. For some compounds,...
The application of the Na2SO -Ln2(SO, -SiCLCLj Y and Gd) electrolyte samples as the solid electrolyte for an SC gas detector was investigated. The EMF measurements were conducted by both the SC gas concentration cell(33) and the solid reference electrode(34) methods. Several efforts have been concentrated on the development of the appropriate reference electrode. In our study, the sulfate-oxide solid reference electrode method was adopted. [Pg.122]

The variety of sampling methods that are available, ie dilute and concentrated samples, suspensions, solids, surfaces and combination with chromatographic methods, such as that used in the high performance liquid chromatography separation of o-phthalyl dialdehyde derivatised amino acids in natural and sea water samples. [Pg.28]


See other pages where Solids concentration sampling methods is mentioned: [Pg.1678]    [Pg.1679]    [Pg.124]    [Pg.267]    [Pg.269]    [Pg.931]    [Pg.422]    [Pg.113]    [Pg.183]    [Pg.1249]    [Pg.28]    [Pg.1116]    [Pg.4]    [Pg.163]    [Pg.434]    [Pg.102]    [Pg.546]    [Pg.1249]    [Pg.145]    [Pg.155]    [Pg.199]    [Pg.198]    [Pg.150]    [Pg.419]    [Pg.446]    [Pg.562]    [Pg.282]    [Pg.192]    [Pg.250]    [Pg.844]    [Pg.150]    [Pg.132]    [Pg.1499]    [Pg.1500]    [Pg.265]    [Pg.266]    [Pg.106]    [Pg.69]    [Pg.512]    [Pg.247]    [Pg.171]    [Pg.176]    [Pg.176]   
See also in sourсe #XX -- [ Pg.176 , Pg.177 , Pg.178 , Pg.179 , Pg.180 , Pg.181 , Pg.182 , Pg.183 , Pg.184 , Pg.185 , Pg.186 , Pg.187 , Pg.188 , Pg.189 , Pg.190 , Pg.191 , Pg.192 , Pg.193 ]




SEARCH



Concentration methods

Sample concentration

Sample methods

Sample solid samples

Sampling concentration

Sampling methods

Sampling solids

Solid concentration

Solid methods

© 2024 chempedia.info