Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solid miniaturized

R/0 unit Reverse Osmosis Unit for water purification in small aquariums and miniature yard-ponds, utilizes a membrane under pressure to filter dissolved solids and pollutants from the water. Two different filter membranes can be used the CTA (cellulose triacetate) membrane is less expensive, but only works with chlorinated water and removes 50-70% of nitrates, and the TFC membrane, which is more expensive, removes 95% of nitrates, but is ruined by chlorine. R/0 wastes water and a system that cleans 100 gallons a day will cost ft-om 400 to 600 with membrane replacement adding to the cost. A unit that handles 140 gallons a day will cost above 700,00. [Pg.624]

Such sensors utilizing solid-state electronics have significant advantages. The actual sensing area is very small. Hence, a single miniaturized solid-state chip could contain multiple gates and be used to sense several ions simultaneously. Other advantages include the in-situ impedance transformation and the ability for temperature and noise compensation. While the concept of the ISFET is very... [Pg.191]

During the last few years, miniaturization has become a dominant trend in the analysis of low-level contaminants in food and environmental samples. This has resulted in a significant reduction in the volume of hazardous and expensive solvents. Typical examples of miniaturization in sample preparation techniques are micro liquid/liquid extractions (in-vial) and solvent-free techniques such as solid-phase microextraction (SPME). Combined with state-of-the-art analytical instrumentation, this trend has resulted in faster analyses, higher sample throughputs and lower solvent consumption, whilst maintaining or even increasing assay sensitivity. [Pg.728]

In this design, on-column sample enrichment is incorporated into the sheathless interface (Janini et al., 2003). A miniaturized solid-phase extraction (mSPE) cartridge, made of reversed-phase material, was attached to the CE capillary near the injection end as shown in Fig. 16.1. [Pg.370]

Although a few amperometric pH sensors are reported [32], most pH electrodes are potentiometric sensors. Among various potentiometric pH sensors, conventional glass pH electrodes are widely used and the pH value measured using a glass electrode is often considered as a gold standard in the development and calibration of other novel pH sensors in vivo and in vitro [33], Other pH electrodes, such as metal/metal oxide and ISFETs have received more and more attention in recent years due to their robustness, fast response, all-solid format and capability for miniaturization. Potentiometric microelectrodes for pH measurements will be the focus of this chapter. [Pg.287]

Although glass pH electrodes are, in general, simple to use and available at a reasonable cost, they are limited by the potential problems of glass breakage [65] and miniaturization difficulties [60, 66], One of the alternative approaches to preparation of non-glass pH sensors is to use polymer-based pH sensitive membranes to replace solid glass membranes. [Pg.295]


See other pages where Solid miniaturized is mentioned: [Pg.1130]    [Pg.2]    [Pg.406]    [Pg.54]    [Pg.521]    [Pg.499]    [Pg.765]    [Pg.191]    [Pg.193]    [Pg.26]    [Pg.359]    [Pg.419]    [Pg.4]    [Pg.206]    [Pg.179]    [Pg.326]    [Pg.304]    [Pg.430]    [Pg.128]    [Pg.230]    [Pg.59]    [Pg.128]    [Pg.651]    [Pg.243]    [Pg.229]    [Pg.18]    [Pg.96]    [Pg.108]    [Pg.153]    [Pg.299]    [Pg.302]    [Pg.303]    [Pg.304]    [Pg.305]    [Pg.388]    [Pg.219]    [Pg.385]    [Pg.173]    [Pg.15]    [Pg.77]    [Pg.488]    [Pg.30]    [Pg.350]    [Pg.19]    [Pg.627]   
See also in sourсe #XX -- [ Pg.400 ]

See also in sourсe #XX -- [ Pg.3 , Pg.30 , Pg.109 ]




SEARCH



Low-Temperature Miniature Batteries with Solid Electrolytes

Miniature

Miniaturization

Miniaturized solid-phase extraction

© 2024 chempedia.info