Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Size exclusion chromatography, for

Goto, M McCoy, BJ, Inverse Size-Exclusion Chromatography for Distributed Pore and Solute Sizes, Chemical Engineering Science 55, 723, 2000. [Pg.612]

The ideal packing should be relatively large in diameter, 80-100 nm, and be available with a pore size range from 500 to 10,000 A. The ores should be uniform in size distribution and shallow to reduce diffusion times. Improvements of this type will lead to the use of size exclusion chromatography for particle size determinations in the routine manner in which it is now employed for molecular weight determinations. [Pg.43]

Russell, D. J., Calibration of high performance size exclusion chromatography for small epoxy molecules, /. Liquid Chromatogr., 11, 383, 1988. [Pg.365]

Nave, R., Weber, K., and Potschka, M., Universal calibration of size-exclusion chromatography for proteins in guanidinium hydrochloride including the high-molecular-mass proteins titin and nebulin,. Chromatogr. A, 654, 229, 1993. [Pg.367]

Mori, S., Wada, A., Kaneuchi, F., Ikeda, A., Watanabe, M., and Mochizuki, K., Design of a highly sensitive infrared detector and application to a high-performance size exclusion chromatography for copolymer analysis, /. Chromatogr., 246, 215, 1982. [Pg.370]

Gysler, J., Mazereeuw, M., Helk, B., Heitzmann, M., Jaehde, U., Schunack, W., Tjaden, U.R., and van der Greef, J., Utility of isotachophoresis-capillary zone electrophoresis, mass spectrometry and high-performance size-exclusion chromatography for monitoring of interleukin-6 dimer formation, /. Chromatogr. A, 841, 63, 1999. [Pg.381]

Detection in 2DLC is the same as encountered in one-dimensional HPLC. A variety of detectors are presented in Table 5.2. The choice of detector is dependent on the molecule being detected, the problem being solved, and the separation mode used for the second dimension. If MS detection is utilized, then volatile buffers are typically used in the second-dimension separation. Ultraviolet detection is used for peptides, proteins, and any molecules that contain an appropriate chromophore. Evaporative light scattering detection has become popular for the analysis of polymers and surfactants that do not contain UV chromophores. Refractive index (RI) detection is generally used with size exclusion chromatography for the analysis of polymers. [Pg.109]

Remove excess crosslinker and reaction by-products by dialysis or size exclusion chromatography. For small quantities of bait proteins, dialysis may be the better choice, because gel filtration columns often bind nonspecifically enough protein to make recoveries unacceptably low. [Pg.1027]

There are usually three types of materials that are employed in the size-exclusion chromatography for pharmaceutical substances which have been discussed briefly as under ... [Pg.478]

Fig. 3.1 Schematic of ALIS, an automated /igand identification system that uses continuous size-exclusion chromatography for the study of protein-ligand interactions. Fig. 3.1 Schematic of ALIS, an automated /igand identification system that uses continuous size-exclusion chromatography for the study of protein-ligand interactions.
The size exclusion chromatography for this study was done in the routine manner execept for the inclusion of an online viscosity detector called a Differential Viscometer <3> (Viscotek Corp., Porter, Texas, USAl. This instrument together with an RI concentration detector permits the calculation of intrinsic viscosities across the chromatogram. An IBM PC data system with software is also provided (5). The software acquires data from both detectors, and performs calculations of intrinsic viscosity and molecular weight distributions using the Universal Calibration Method. [Pg.119]

High performance liquid chromatography (HPLC) of polymers is often thought to be synonymous with Size Exclusion Chromatography for separation by molar size. The present article deals with nonexclusion chromatography of polymers which enables separation by differences in the chemical structure and composition. [Pg.159]

Fig. 13. Comparison of cumulative weight distributions FW)CUm(M) [= Jm fw(M)dM ] obtained by DLS and SEC (size exclusion chromatography) for a linear polyethylene in 1,2,4-trichlorobenzene at 135 °C... Fig. 13. Comparison of cumulative weight distributions FW)CUm(M) [= Jm fw(M)dM ] obtained by DLS and SEC (size exclusion chromatography) for a linear polyethylene in 1,2,4-trichlorobenzene at 135 °C...
Number average molecular weight data from size exclusion chromatography for polymers A through E has been given previously... [Pg.115]

Boger DL, Goldberg J, Andersson CM, Solution phase combinatorial synthesis of biaryl libraries employing heterogeneous conditions for catalysis and isolation with size exclusion chromatography for purification, J. Org. Chem., 64 2422-2429, 1999. [Pg.142]

As stated in Section 8.2.1, only limited results concerning Mw determinations of lignins with the use of LALLS photometry have been published. This radically new and sophisticated technique constitutes an improvement over other methods, such as sedimentation equilibrium and size exclusion chromatography, for the evaluation of Mw. Its low angle capability, combined with high sensitivity, small sample size, and simplified clarification procedures, allow simple and accurate determinations to be made even on lignin samples which have been considered very troublesome. Moreover, as stated in Section 8.2.2, additional difficulties, inherent lignin properties, i.e., absorbance, fluorescence and anisotropy, may also be overcome. [Pg.504]

The separation range in size-exclusion chromatography for a particular column is relatively narrow, and it lies between the total volume of the liquid phase in the column (void volume) and the exclusion volume, Ve. The difference between these two volumes is the total pore volume of the packing material in the column. Indeed, if some molecules of studied polymers are small enough to penetrate inside all pores of the packing material, they will elute with the column void volume. On the other hand, polymers with significant molecular size that cannot penetrate inside the particles will all travel together around the particles and elute early with exclusion volume. [Pg.271]

Ultrafiltration is conducted to remove precipitating agents such as ethanol, PEG, and caprylic acid through diafiltration and to concentrate the protein to the desired level. It has replaced lyophilization for ethanol removal from albumin and immunoglobulins and size exclusion chromatography for buffer exchange. [Pg.418]

HPLC provides reliable quantitative precision and accuracy, along with a linear dynamic range (LDR) sufficient to allow for the determination of the API and related substances in the same run using a variety of detectors, and can be performed on fully automated instrumentation. HPLC provides excellent reproducibility and is applicable to a wide array of compound types by judicious choice of HPLC column chemistry. Major modes of HPLC include reversed phase and normal phase for the analysis of small (<2000 Da) organic molecules, ion chromatography for the analysis of ions, size exclusion chromatography for the separation of polymers, and chiral HPLC for the determination of enantiomeric purity. Numerous chemically different columns are available within each broad classification, to further aid method development. [Pg.349]

Harrison CA, Tan JS. Differential size-exclusion chromatography for the analysis of gelatin-polyelectrolyte complexes. J Polym Sci Part B Polym Phys 1999 37 275-280. [Pg.790]

Size exclusion chromatography (for monomer content) Carbohydrate profile Deamidated species (%)... [Pg.448]

Figure 4.6-6 Arrhenius plot of the inverse average degree of polymerization, determined by either viscosimetry or size-exclusion chromatography for polyethylenes produced at 2000 bar and various temperatures T, the initiation and thus termination rates are very low in these experiments [37,38].h... Figure 4.6-6 Arrhenius plot of the inverse average degree of polymerization, determined by either viscosimetry or size-exclusion chromatography for polyethylenes produced at 2000 bar and various temperatures T, the initiation and thus termination rates are very low in these experiments [37,38].h...
The last part of the book, Chapters 10—17, reports on different applications of polymers in the field of analytical chemistry sorption of organic compounds, Hke phenols, pesticides or caffeine, the use of polymeric materials for size-exclusion chromatography, for HPLC packing materials or as solid phase extraction sorbents. The examples cover a broad variety of chemical compounds, fike pesticides, pharmaceuticals, organic acids in different matrices, such as food, biological fluids, non-aqueous media, air and the use of hemosorbents in blood purification. [Pg.661]

Himt, S.M., Sheil, M., and Derrick, P.J., Comparison of Electrospray lonization-MS and MALDI-MS and Size Exclusion Chromatography for the Characterization of Polyester Resins, Ear. Mass Spectrom., 4, 475 (1998). [Pg.117]

Sanchez-Muniz, F.J., Cuesta, C., and Garrrido-Polonio, C. 1993. Sunflower oU used for frying Combination of column, gas and high-performance size-exclusion chromatography for its evaluation, J. Am. Oil Chem. Soc., 70 235-240. [Pg.1206]


See other pages where Size exclusion chromatography, for is mentioned: [Pg.595]    [Pg.57]    [Pg.257]    [Pg.539]    [Pg.166]    [Pg.2]    [Pg.256]    [Pg.1]    [Pg.76]    [Pg.76]    [Pg.122]    [Pg.781]    [Pg.1016]    [Pg.427]    [Pg.256]    [Pg.448]    [Pg.327]    [Pg.255]    [Pg.150]    [Pg.329]    [Pg.201]   


SEARCH



Applications for Size-Exclusion Chromatography

Detectors, for size exclusion chromatography

Gel Matrices for Size Exclusion Chromatography

Mobile Phases for Size-Exclusion Chromatography

Size chromatography

Size-exclusion

© 2024 chempedia.info