Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Silver corrosion potentials

The corrosion potential, Ecoa for iron in aerated water is in the range of —600 to —700 mV at pH 7 against the silver-silver chloride reference electrode (Point 0). By decreasing the pH below 7.0 the system is unaffected and corrosion persists. Increase in pH moves the system into a passive region, but this type of perturbation of the system is not the focus of the present discussion. By applying a more negative potential it is possible to move the system into the region of immunity which means the corrosion susceptibility is reduced. [Pg.101]

Hoffman and Friedman [106] proposed a mechanism for the induction time in development based on heterogeneous electrochemical theories of corrosion. The model explains the empirical relation derived by Pontius and Willis. In this case the two half-cell reactions of silver and developer give rise to a mixed or corrosion potential, Ecorr, which if electron transfer is rate-limiting can be described by Eq. (74),... [Pg.3501]

The metals must have sufficiently positive half-cell potentials that corrosive reactions that would change the potential to a corrosion potential, Ecorr, do not occur. This requirement, with few exceptions, restricts the metal component of the half cell to silver, mercury, and copper. For these metals, appearing in Table 6.1, corrosion due to hydrogen evolution will not occur since the metal half-cell potentials are above potentials for hydrogen evolution. Also, the kinetics of the reduction of any dissolved oxygen are sufficiently slow that the potential is shifted negligibly from that of the metal half cell. [Pg.241]

An aging atudy has heen completed which evaluated a number of polymeric materials for potential use as 1) protective coatings for back surfaces of mirrors and 2) solar hellostat edge seals. These investigations were conducted in an artificial weathering chamber that accelerated thermal cycling. We observed the primary mirror failure mode to be silver corrosion resulting from moisture exposure. [Pg.115]

Electrochemical corrosion monitoring in batch [157,161] and continuous digesters [162] has been accomplished using reference electrode probes that permit the measurement of the corrosion potential. The corrosion potential of the digester wall has been measured with respect to molybdenum, stainless steel, and silver/silver sulfide reference electrodes. Pawel et al. [763] have used electrochemical noise to monitor corrosion in a continuous digester. [Pg.801]

Localized corrosion is not always related to aggressive anions. Pits may form on metal surfaces due to imperfect passivation. This may be a consequence of a poor film quality or the action of metallic inclusions. Two examples have been already mentioned in Chapter 5. One example is the localized corrosion of silver at potentials corresponding to early film formation (Chapter 5), another one is the effect of Cu inclusions on passivity breakdown of Al (Chapter 5). [Pg.370]

Silver reduces the oxygen evolution potential at the anode, which reduces the rate of corrosion and decreases lead contamination of the cathode. Lead—antimony—silver alloy anodes are used for the production of thin copper foil for use in electronics. Lead—silver (2 wt %), lead—silver (1 wt %)—tin (1 wt %), and lead—antimony (6 wt %)—silver (1—2 wt %) alloys ate used as anodes in cathodic protection of steel pipes and stmctures in fresh, brackish, or seawater. The lead dioxide layer is not only conductive, but also resists decomposition in chloride environments. Silver-free alloys rapidly become passivated and scale badly in seawater. Silver is also added to the positive grids of lead—acid batteries in small amounts (0.005—0.05 wt %) to reduce the rate of corrosion. [Pg.61]

Laister and Benham have shown that under more arduous conditions (immersion for 6 months in sea-water) a minimum thickness of 0-025 mm of silver is required to protect steel, even when the silver is itself further protected by a thin rhodium coating. In similar circumstances brass was completely protected by 0 012 5 mm of silver. The use of an undercoating deposit of intermediate electrode potential is generally desirable when precious metal coatings are applied to more reactive base metals, e.g. steel, zinc alloys and aluminium, since otherwise corrosion at discontinuities in the coating will be accelerated by the high e.m.f. of the couple formed between the coating and the basis metal. The thickness of undercoat may have to be increased substantially above the values indicated if the basis metal is affected by special defects such as porosity. [Pg.559]

Various types of reference electrodes have been considered in Section 20.3, and the potentials of these electrodes and their variation with the activity of the electrolyte are listed in Table 21.7, Chapter 21. It is appropriate, however to point out here that the saturated calomel electrode (S.C.E.), the silver-silver chloride electrode and the copper-copper sulphate electrode are the most widely used in corrosion testing and monitoring. [Pg.1010]

These considerations show the essentially thermodynamic nature of and it follows that only those metals that form reversible -i-ze = A/systems, and that are immersed in solutions containing their cations, take up potentials that conform to the thermodynamic Nernst equation. It is evident, therefore, that the e.m.f. series of metals has little relevance in relation to the actual potential of a metal in a practical environment, and although metals such as silver, mercury, copper, tin, cadmium, zinc, etc. when immersed in solutions of their cations do form reversible systems, they are unlikely to be in contact with environments containing unit activities of their cations. Furthermore, although silver when immersed in a solution of Ag ions will take up the reversible potential of the Ag /Ag equilibrium, similar considerations do not apply to the NaVNa equilibrium since in this case the sodium will react with the water with the evolution of hydrogen gas, i.e. two exchange processes will occur, resulting in an extreme case of a corrosion reaction. [Pg.1248]

Other metals, such as copper, nickel, or silver, have been used as electrode materials in connection with specific applications, such as the detection of amino acids or carbohydrates in alkaline media (copper and nickel) and cyanide or sulfur compounds (silver). Unlike platinum or gold electrodes, these electrodes offer a stable response for carbohydrates at constant potentials, through the formation of high-valence oxyhydroxide species formed in situ on the surface and believed to act as redox mediators (40,41). Bismuth film electrodes (preplated or in situ plated ones) have been shown to be an attractive alternative to mercury films used for stripping voltammetry of trace metals (42,43). Alloy electrodes (e.g., platinum-ruthenium, nickel-titanium) are also being used for addressing adsorption or corrosion effects of one of their components. The bifunctional catalytic mechanism of alloy electrodes (such as Pt-Ru or Pt-Sn ones) has been particularly useful for fuel cell applications (44). [Pg.135]

Fig. 31. Experimental potential fronts (a) during the corrosion of gold in a concentrated HCl/NaCl solution (after Ref. [85]) (b) during the potentiostatic reduction of SgOg2 on a silver ring electrode in dilute electrolyte [166], On the left are the corresponding set-ups. Fig. 31. Experimental potential fronts (a) during the corrosion of gold in a concentrated HCl/NaCl solution (after Ref. [85]) (b) during the potentiostatic reduction of SgOg2 on a silver ring electrode in dilute electrolyte [166], On the left are the corresponding set-ups.

See other pages where Silver corrosion potentials is mentioned: [Pg.6]    [Pg.233]    [Pg.689]    [Pg.845]    [Pg.853]    [Pg.271]    [Pg.274]    [Pg.425]    [Pg.318]    [Pg.535]    [Pg.228]    [Pg.208]    [Pg.63]    [Pg.63]    [Pg.237]    [Pg.735]    [Pg.929]    [Pg.943]    [Pg.943]    [Pg.346]    [Pg.511]    [Pg.561]    [Pg.229]    [Pg.242]    [Pg.182]    [Pg.274]    [Pg.248]    [Pg.136]    [Pg.137]    [Pg.127]    [Pg.535]    [Pg.61]    [Pg.784]    [Pg.379]    [Pg.483]    [Pg.676]   