Shaped beam

Curvature and rotation lenses correct for any imperfections (aberrations) in the cross-sectional shape of the beam before it reaches the collector slit. The curvature lens provides a means of changing any banana-shaped beam cross-section into a rectangular shape (Figure 24.8). The rotation lens rotates the beam such that the sides of the beam become parallel with the long axis of the collector slit (Figure 24.8). [Pg.179]

With shaped beams the source for the electron optical column is an image of a square aperture that is formed in the plane of a second square... [Pg.22]

Lanthanum hexaboride cathodes fall short of the required brightness for a round beam to compete with a shaped beam only producing lxl06 A/cm2.ster. (25 kV) with adequate reliability for unattended production applications (40). In summary, highest throughput in production is obtained with shaped beams. [Pg.23]

EBES-like systems are used extensively for mask making. They can make masks with dimensions as small as 0.5 jxm, and 3a overlay accuracy approaching 0.1 jam. They generally use a small round beam, although shaped beam versions have also been described (40). [Pg.24]

The key specifications of EL3 are shown in Table I. EL3 combines a high current variable shaped beam column with a dual deflection system (42). Maximum beam size is 4 jam x 4 jam and shapes smaller than this are available in 0.1 m increments. Spot edge definition is better than 0.2 jam. A highly accurate but relatively slow magnetic deflection coil deflects the beam in a raster sequence to the center of an array of 75 jim subfields. The variable... [Pg.24]

The most obvious way to improve throughput in scanning electron beam systems is to combine a variable shaped beam column, with a continuously moving table. The shaped beam ensures maximum beam current, and the continuously moving table potentially eliminates many overhead times. Registration can be accomplished without stopping the table, either by means of a laser interferometer, or through direct beam to sample reference. [Pg.25]

The liquid injection is realized using a two-fluid nozzle (Co. Schlick, type 943, form 3, ring-shaped beam 20°-40°, dnozzie = 2.3 mm). A adjustable hose pump conveys the liquid from a store tank, and compressed air is used for the better spreading of the liquid. The investigations of Henneberg et al. [38, 39] in an industrial fluidized-bed plant showed that high nozzle injection rates may lead to low particle concentrations near the nozzle, and to overspray. [Pg.479]

A slit shaped beam brings light on to the chromatoplate. The plate lies on a table which moves with an adjustable constant velocity linearly under the slit. This procedure is also called linear scan in the literature. For circular or anticircular developed... [Pg.100]

In the experiment above the light was collimated with a lens. Therefore, the Gaussian shaped beam profile introduced weaker illumination of the camera at the edges than in the center. Figure 6b shows the reference profile fin for this geometry. For optimum performance the reference hne should be positioned in close proximity to the LVF hue. [Pg.39]

The cantilevers can be fabricated of any shape and from substantially any material utilized in microelectronics industry, i.e. crystalline or poly-silicon, silicon nitride, silicon oxide, polymer materials (see Note 2). The rectangular shape beams are the most frequently used in biological research. In biological sensors based on the bending method, it is important to have the cantilevers flat and in plane with the base surface. Initial offset or curvature of the beams complicates adjustment of the experimental setup, especially, if working with arrays of cantilever. For this reason, the most common material for cantilevers fabrication nowadays is single crystalline silicon. A large variety of biomolecular interactions have been detected with silicon microcantilevers. [Pg.52]

There are elements of beamlines that are generally common among the three major types of implanters. All beamlines begin with an ion source and extraction optics, responsible for injecting an appropriately shaped beam of ions into the subsequent... [Pg.215]


See other pages where Shaped beam is mentioned: [Pg.134]    [Pg.9]    [Pg.100]    [Pg.20]    [Pg.269]    [Pg.66]    [Pg.66]    [Pg.69]    [Pg.69]    [Pg.70]    [Pg.71]    [Pg.213]    [Pg.231]    [Pg.232]    [Pg.234]    [Pg.22]    [Pg.22]    [Pg.23]    [Pg.23]    [Pg.24]    [Pg.24]    [Pg.25]    [Pg.35]    [Pg.134]    [Pg.82]    [Pg.284]    [Pg.376]    [Pg.134]    [Pg.350]    [Pg.83]    [Pg.100]    [Pg.313]    [Pg.285]    [Pg.202]    [Pg.747]   