Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensor biological

There is a vast amount of literature on the subject of impedance measurements comprising a large number of different applications, such as corrosion, characterization of thin films and coatings, batteries, semiconductor electrodes, sensors, biological systems, and many more. It is beyond the scope of this article to cover all of these applications comprehensively. This chapter, therefore, concentrates on the description of the main principles and theories and selected applications of impedance methods. A more thorough treatment of the subject from the point of view of corrosion can be found in [1, 2], impedance spectroscopy of solid systems is described in [3]. The fundamentals of impedance spectroscopy of electrochemical systems are also explained in [4, 5]. [Pg.196]

Enzymes are important catalysts in biological organisms and are of increasing use in detergents and sensors. It is of interest to understand not only their adsorption characteristics but also their catalytic activity on the surface. The interplay between adsorption and deactivation has been clearly illustrated [119] as has the ability of a protein to cleave a surface-bound substrate [120]. [Pg.404]

Many complex systems have been spread on liquid interfaces for a variety of reasons. We begin this chapter with a discussion of the behavior of synthetic polymers at the liquid-air interface. Most of these systems are linear macromolecules however, rigid-rod polymers and more complex structures are of interest for potential optoelectronic applications. Biological macromolecules are spread at the liquid-vapor interface to fabricate sensors and other biomedical devices. In addition, the study of proteins at the air-water interface yields important information on enzymatic recognition, and membrane protein behavior. We touch on other biological systems, namely, phospholipids and cholesterol monolayers. These systems are so widely and routinely studied these days that they were also mentioned in some detail in Chapter IV. The closely related matter of bilayers and vesicles is also briefly addressed. [Pg.537]

Chemical and biological sensors (qv) are important appHcations of LB films. In field-effect devices, the tunneling current is a function of the dielectric constant of the organic film (85—90). For example, NO2, an electron acceptor, has been detected by a phthalocyanine (or a porphyrin) LB film. The mechanism of the reaction is a partial oxidation that introduces charge carriers into the film, thus changing its band gap and as a result, its dc-conductivity. Field-effect devices are very sensitive, but not selective. [Pg.536]

Most controlled release dosage forms administer dmg according to thek design, whether conceptually simple, eg, a fixed release rate for a fixed amount of time, or complex, eg, several different rates for different amounts of time. Alternatively, closed-loop systems contain a sensor to monitor dmg concentration or to administer dmg according to a biological need (11). [Pg.140]

Biosensors ai e widely used to the detection of hazardous contaminants in foodstuffs, soil and fresh waters. Due to high sensitivity, simple design, low cost and real-time measurement mode biosensors ai e considered as an alternative to conventional analytical techniques, e.g. GC or HPLC. Although the sensitivity and selectivity of contaminant detection is mainly determined by a biological component, i.e. enzyme or antibodies, the biosensor performance can be efficiently controlled by the optimization of its assembly and working conditions. In this report, the prospects to the improvement of pesticide detection with cholinesterase sensors based on modified screen-printed electrodes are summarized. The following opportunities for the controlled improvement of analytical characteristics of anticholinesterase pesticides ai e discussed ... [Pg.295]

A lot of analytical techniques have been proposed in recent decades and most of them are based on enzymes, called dehydrogenases, which are not sensitive to oxygen and need cofactors such as NAD". The key problems which seriously hamper a wide commercialization of biosensors and enzymatic kits based on NAD-dependent enzymes are necessity to add exogenous cofactor (NAD" ) into the samples to be analyzed to incorporate into the biologically active membrane of sensors covalently bounded NAD" to supply the analytical technique by NAD -regeneration systems. [Pg.303]

In many cases, problems cannot be overcome by biological means. This is especially true for those related to inhibition by substrate or product. There may, however, be technical solutions to these problems. Nowadays, complicated feed strategies with different substrates can be achieved through the use of flow injection analysis, on-line sensors, mass flow meters and sophisticated computer control. Such control coupled to a fed-batch mode of operation (Figure 2.5) can often eleviate problems caused by substrate inhibition. For some processes, continuous product removal can avoid the problems associated with product inhibition the various options include ... [Pg.30]

D. Diamond, Chemical and Biological Sensors, Wiley, New York, 1998. [Pg.26]


See other pages where Sensor biological is mentioned: [Pg.143]    [Pg.822]    [Pg.435]    [Pg.96]    [Pg.148]    [Pg.36]    [Pg.191]    [Pg.145]    [Pg.156]    [Pg.143]    [Pg.822]    [Pg.435]    [Pg.96]    [Pg.148]    [Pg.36]    [Pg.191]    [Pg.145]    [Pg.156]    [Pg.403]    [Pg.1940]    [Pg.525]    [Pg.201]    [Pg.202]    [Pg.209]    [Pg.249]    [Pg.465]    [Pg.188]    [Pg.396]    [Pg.396]    [Pg.391]    [Pg.392]    [Pg.18]    [Pg.300]    [Pg.323]    [Pg.265]    [Pg.71]    [Pg.79]    [Pg.1]    [Pg.127]    [Pg.171]    [Pg.172]    [Pg.186]    [Pg.187]    [Pg.187]    [Pg.192]    [Pg.3]    [Pg.51]    [Pg.160]   
See also in sourсe #XX -- [ Pg.150 , Pg.155 , Pg.167 , Pg.168 ]

See also in sourсe #XX -- [ Pg.12 , Pg.12 , Pg.12 , Pg.12 , Pg.13 , Pg.13 , Pg.13 , Pg.13 , Pg.14 , Pg.14 , Pg.14 , Pg.15 , Pg.15 , Pg.15 , Pg.16 , Pg.16 , Pg.16 , Pg.17 , Pg.17 , Pg.17 , Pg.18 , Pg.18 , Pg.18 , Pg.19 , Pg.19 , Pg.19 , Pg.20 , Pg.20 , Pg.21 , Pg.22 , Pg.23 , Pg.24 , Pg.25 , Pg.26 , Pg.27 , Pg.28 ]




SEARCH



Autonomous Field-Deployable Sensors for Biological Agents

Biological agent sensors

Biological change sensors

Biological chemistry fluorescent sensors

Biological odorant sensors

Biological sensor biosensor

Biological sensor, definition

Biological sensors, electrically active polymers

Biological system, sensors

Chemical and biological sensors based on polythiophenes

In Chemical and Biological Sensors for Environmental Monitoring Mulchandani

Photoluminescence biological sensors

© 2024 chempedia.info