Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensors proof pressure

The volume of the nitration reactor is about 110 L equipped with an explosion proof motor, a cycloidal reducer, mechanical seals, an anchor agitator, a temperature sensor, a pressure gauge, three feeding holes with different size, a segregator with a glass mirror, 1,000 mm condenser, and a jacket of heat transfer oil. The system also includes a temperature controller, an agitation controller, and a washing vessel. By application of the production unit, the yield of n-butyl nitrate is up to 95.7 % with the purity of 98.88 %. [Pg.207]

The enzyme matrix of the Bessman-Schultz sensor is made of thin closely-woven rayon acetate cloth (coated on one side with water-proof pressure-sensitive adhesive) impregnated with a glucose oxidase mixture, dried in air, and cross-linked with glutar-aldehyde. The resultant covalently-bound enzyme is very resistant to degradation by body fluids, showing less than 10 percent decrease in its response to physiological concentrations of glucose after subcutaneous implantation in a rabbit for 11 days and only about 50 percent loss in activity after 6 months. vitro,... [Pg.193]

The specific test was made into a specialized bunker of one partner of the CIAPES program. All the vessel was covered by AE sensors to locate witli accuracy AE sources. The corrosion defect was situated on the bottom of the vessel. The service pressure of the vessel was 8 bars, so the vessel was first submitted to a proof test at 12 bars. During this test, the pressure was increased with load holds in order to verify the assessment criteria. After the first hold at 4 bars, a cluster was located at the position of the defect. The number of events located in this cluster increased during all the test (figure 1). [Pg.54]

Sensors for measurements of physical parameters such as pressure, rotation or acceleration are commonly based on elongation or vibration of membranes, cantilevers or other proof masses. The electrochemical processes used to achieve these micromechanical structures are commonly etch-stop techniques, as discussed in Section 4.5, or sacrificial layer techniques, discussed in Section 10.7. [Pg.219]

The test apparatus consists of an explosion-proof water tank 10 m in diameter and 5m deep and a bridge and frame to support the sample and a pressure sensor. [Pg.233]

The pressures on Process Chemistry are mounting rapidly Industry seeks rapid entry into the clinic, postponing development spend until proof of concept, then rapid conunerciaUzation once benefit is established. External and internal trends look for more complete data, deep process understanding, absolute control of genotoxic impurities, establishing of design space and quality by design, and real time control of the process via on line sensors. [Pg.486]


See other pages where Sensors proof pressure is mentioned: [Pg.443]    [Pg.369]    [Pg.40]    [Pg.443]    [Pg.285]    [Pg.350]    [Pg.1259]    [Pg.837]    [Pg.78]    [Pg.79]    [Pg.288]    [Pg.91]    [Pg.1886]    [Pg.692]    [Pg.116]    [Pg.151]    [Pg.166]    [Pg.151]    [Pg.166]    [Pg.337]    [Pg.341]    [Pg.358]    [Pg.365]    [Pg.147]   
See also in sourсe #XX -- [ Pg.383 ]




SEARCH



Proof pressure

Proofing

© 2024 chempedia.info